COMPARISON OF THE CONDITION OF THE PERI-IMPLANT ORAL MUCOUS ACCORDING TO THE RESULTS OF DIGITAL MICROSCOPY

D. Korol, A. Yefimenko, M. Korol
{"title":"COMPARISON OF THE CONDITION OF THE PERI-IMPLANT ORAL MUCOUS ACCORDING TO THE RESULTS OF DIGITAL MICROSCOPY","authors":"D. Korol, A. Yefimenko, M. Korol","doi":"10.21303/2313-8416.2020.001558","DOIUrl":null,"url":null,"abstract":"The object of the study there is a level of hyperemia of the mucous membrane around the installed intraosseous dental implants with different coating material according to the results of histogram analysis of digital microscopy. The problem to be solved – evaluation of the degree of hyperemia of the periimplant mucosa around intraosseous dental implants coated with rutile, in comparison with titanium implants of VT-6 alloy after prosthetics. Main scientific results: Analysis of digital images using histogram evaluation of the red component of the spectrum showed that 1 month after prosthetics in group 1, which included 20 patients who had intraosseous implants made of titanium alloy TiV6Al (VT-6), the above indicator increased to 191 (St.Err. 4.45). The difference was 4 conventional units. Similarly, in group 2 (16 people) who had intraosseous zirconium implants, there was an increase in the quantitative rate after prosthetics by 9 conventional units, and its value was 194 conventional units (St.Err. 3.64). Since increasing numerical values ​​and shifting the digital histogram to the right is an objective criterion for reducing the intensity of redness, it can be concluded that there is a reduction of mucosal irritation after orthopedic treatment with a predominance of this process in the group of patients who received intraosseous dental implants coated with rutile. The area of practical use of research results:     Since the authors first studied the reaction of the peri-implant mucosa in contact with various implant materials at the stages of orthopedic treatment, this is the basis for the introduction into general medical practice of intraosseous dental implants made in Ukraine using rutile application technology. The area of application of an innovative technological product - it is a dental implant practice. The obtained results will allow to use more widely Ukrainian implants of non-demountable construction with a high level of surface preparation, for the purpose of further orthopedic treatment with the use of non-removable metal-ceramic dentures.","PeriodicalId":30651,"journal":{"name":"ScienceRise","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ScienceRise","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21303/2313-8416.2020.001558","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The object of the study there is a level of hyperemia of the mucous membrane around the installed intraosseous dental implants with different coating material according to the results of histogram analysis of digital microscopy. The problem to be solved – evaluation of the degree of hyperemia of the periimplant mucosa around intraosseous dental implants coated with rutile, in comparison with titanium implants of VT-6 alloy after prosthetics. Main scientific results: Analysis of digital images using histogram evaluation of the red component of the spectrum showed that 1 month after prosthetics in group 1, which included 20 patients who had intraosseous implants made of titanium alloy TiV6Al (VT-6), the above indicator increased to 191 (St.Err. 4.45). The difference was 4 conventional units. Similarly, in group 2 (16 people) who had intraosseous zirconium implants, there was an increase in the quantitative rate after prosthetics by 9 conventional units, and its value was 194 conventional units (St.Err. 3.64). Since increasing numerical values ​​and shifting the digital histogram to the right is an objective criterion for reducing the intensity of redness, it can be concluded that there is a reduction of mucosal irritation after orthopedic treatment with a predominance of this process in the group of patients who received intraosseous dental implants coated with rutile. The area of practical use of research results:     Since the authors first studied the reaction of the peri-implant mucosa in contact with various implant materials at the stages of orthopedic treatment, this is the basis for the introduction into general medical practice of intraosseous dental implants made in Ukraine using rutile application technology. The area of application of an innovative technological product - it is a dental implant practice. The obtained results will allow to use more widely Ukrainian implants of non-demountable construction with a high level of surface preparation, for the purpose of further orthopedic treatment with the use of non-removable metal-ceramic dentures.
数字显微镜下种植体周围口腔黏膜状况的比较
根据数码显微镜的直方图分析结果,本研究的对象在不同涂层材料的骨内种植体周围存在一定程度的粘膜充血。待解决的问题——金红石涂层牙种植体与VT-6合金钛种植体修复后种植体周围粘膜充血程度的比较主要科学成果:用直方图评价光谱红色分量的数字图像分析显示,1组20例使用钛合金TiV6Al (VT-6)骨内种植体1个月后,上述指标增加到191 (St.Err.)。4.45)。相差4个常规单位。同样,第2组(16人)骨内锆种植体修复后的定量率增加了9个常规单位,其值为194个常规单位(St.Err.)。3.64)。由于增加数值并将数字直方图向右移动是减少发红强度的客观标准,因此可以得出结论,骨科治疗后粘膜刺激减少,并且在接受金红石涂层的骨内种植体的患者组中,这一过程占主导地位。研究成果的实际应用领域:由于作者首先研究了在骨科治疗阶段种植体周围粘膜与各种种植体材料接触的反应,这是将乌克兰采用金红石应用技术生产的骨内种植体引入一般医疗实践的基础。该领域应用了一种创新的技术产品——它是一种牙科种植实践。获得的结果将允许更广泛地使用乌克兰不可拆卸结构的种植体,具有高水平的表面准备,用于使用不可拆卸金属陶瓷假牙的进一步矫形治疗。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
17
审稿时长
3 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信