{"title":"Research on the Optimization Measures of Intelligent Substation Network Clock Synchronization Applications","authors":"Yu Lei, Ying He, Zhiqiang Xu, Jian Chen","doi":"10.12677/HJWC.2017.72012","DOIUrl":null,"url":null,"abstract":"针对智能变电站业务同步精度影响业务服务质量问题,本文开展智能变电站网络时钟同步应用优化措施研究。首先对当前网络时钟同步技术进行分析比较;结合智能变电站对时钟同步精度的实际要求以及变电站业务实际业务应用的同步需求,从冗余组网、独立网络拓扑和分层对时等方面,通过典型实例阐述同步优化措施,从而实现智能变电站网络时钟同步应用优化的目的。 This paper carries out research on the optimization measures of intelligent substation network clock synchronization applications, aiming at the problem that intelligent substation synchronization precision affects the quality of business services business. First of all, the current network clock synchronization technologies are analyzed and compared. Then, the synchronous optimization measures are introduced through the typical examples in terms of redundant network, independent topology and layered synchronization, considering the intelligent substation actual requirements for precision clock synchronization and synchronization requirements of substation practical business applications. Thereby, the purpose of optimizing intelligent substation network clock synchronization applications is realized.","PeriodicalId":66606,"journal":{"name":"无线通信","volume":"07 1","pages":"97-102"},"PeriodicalIF":0.0000,"publicationDate":"2017-04-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"无线通信","FirstCategoryId":"1093","ListUrlMain":"https://doi.org/10.12677/HJWC.2017.72012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

针对智能变电站业务同步精度影响业务服务质量问题,本文开展智能变电站网络时钟同步应用优化措施研究。首先对当前网络时钟同步技术进行分析比较;结合智能变电站对时钟同步精度的实际要求以及变电站业务实际业务应用的同步需求,从冗余组网、独立网络拓扑和分层对时等方面,通过典型实例阐述同步优化措施,从而实现智能变电站网络时钟同步应用优化的目的。 This paper carries out research on the optimization measures of intelligent substation network clock synchronization applications, aiming at the problem that intelligent substation synchronization precision affects the quality of business services business. First of all, the current network clock synchronization technologies are analyzed and compared. Then, the synchronous optimization measures are introduced through the typical examples in terms of redundant network, independent topology and layered synchronization, considering the intelligent substation actual requirements for precision clock synchronization and synchronization requirements of substation practical business applications. Thereby, the purpose of optimizing intelligent substation network clock synchronization applications is realized.
智能变电站网络时钟同步应用的优化措施研究
In response to the issue of the impact of synchronization accuracy on business service quality in intelligent substations, this article conducts research on optimization measures for clock synchronization application in intelligent substation networks. Firstly, analyze and compare the current network clock synchronization technologies; Based on the actual requirements for clock synchronization accuracy in intelligent substations and the synchronization requirements for practical business applications in substations, this paper elaborates on synchronization optimization measures through typical examples from aspects such as redundant networking, independent network topology, and layered time synchronization, in order to achieve the goal of optimizing clock synchronization applications in intelligent substation networks. This paper carries out research on the optimization measures of intelligent substation network clock synchronization applications, aiming at the problem that intelligent substation synchronization precision affects the quality of business services business First of all, the current network clock synchronization technologies are analyzed and compared Then, the synchronous optimization measures are introduced through the typical examples in terms of redundant network, independent topology and layered synchronization, considering the intelligent substation actual requirements for precision clock synchronization and synchronization requirements of substation practical business applications Thereby, the purpose of optimizing intelligent substation network clock synchronization applications is realized
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
195
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信