{"title":"Optimisation of data transmission delay of heart rate monitoring equipment in sports","authors":"Zhiming Zhong","doi":"10.1504/ijpd.2021.116153","DOIUrl":null,"url":null,"abstract":"In order to overcome the problem of high transmission delay of traditional heart rate monitoring equipment, this paper proposes a new optimisation method for data transmission delay of sports heart rate monitoring equipment. This paper analyses the characteristics of heart rate data under different exercise intensity, constructs the energy consumption model of data transmission, and analyses the operation process of energy consumption model in detail. According to the RBF neural network, the related parameters affecting the data transmission delay of heart rate monitoring equipment are calculated and optimised to complete the optimisation of data transmission delay of heart rate monitoring equipment. The experimental results show that the data delay optimisation method proposed in this paper can effectively reduce the transmission delay, the minimum high delay time is only 60 ms, improve the transmission rate, and has strong practical application.","PeriodicalId":14273,"journal":{"name":"International Journal of Product Development","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Product Development","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1504/ijpd.2021.116153","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Economics, Econometrics and Finance","Score":null,"Total":0}
引用次数: 0
Abstract
In order to overcome the problem of high transmission delay of traditional heart rate monitoring equipment, this paper proposes a new optimisation method for data transmission delay of sports heart rate monitoring equipment. This paper analyses the characteristics of heart rate data under different exercise intensity, constructs the energy consumption model of data transmission, and analyses the operation process of energy consumption model in detail. According to the RBF neural network, the related parameters affecting the data transmission delay of heart rate monitoring equipment are calculated and optimised to complete the optimisation of data transmission delay of heart rate monitoring equipment. The experimental results show that the data delay optimisation method proposed in this paper can effectively reduce the transmission delay, the minimum high delay time is only 60 ms, improve the transmission rate, and has strong practical application.
期刊介绍:
IJPD is a refereed international journal providing an authoritative source of information in the field of product development and innovation. It is devoted to the development, promotion and coordination of the science and practice of this field.