{"title":"Establishment of an ambient air sevoflurane measurement method using ECD-GC","authors":"Koji Yamagata, Yasushi Sakuma, Y. Momota","doi":"10.18905/JODU.51.2_95","DOIUrl":null,"url":null,"abstract":"The experiments were performed using a gas chro matograph (GC 2014 ; Shimadzu Corporation, Kyoto, Japan) equipped with an electron capture detector (ECD) (Fig. 1), and a medium polar col umn (Rtx200 ; Restek Corporation, Bellefronte, PA, USA) with chemically bonded trifluoropropyl methyl polysiloxane as a liquid phase. Experimental samples were prepared by adding sevoflurane into 1 L vacuum sampling bottles (GL Sciences, Tokyo, Japan) filled with indoor air using a micropipette (Eppendorf, Hamburg, Germany). After waiting for the sevoflurane (Maruishi Pharmaceutical, Osaka, Japan) volatilization at room temperature, 20 μL of the sample from the sampling bottle was injected into the gas chromatograph using a micro syringe (Terumo, Tokyo, Japan). Establishment of an ambient air sevoflurane measurement method using ECDGC","PeriodicalId":76018,"journal":{"name":"Journal of Osaka Dental University","volume":"51 1","pages":"95-98"},"PeriodicalIF":0.0000,"publicationDate":"2017-10-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.18905/JODU.51.2_95","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Osaka Dental University","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18905/JODU.51.2_95","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
Abstract
The experiments were performed using a gas chro matograph (GC 2014 ; Shimadzu Corporation, Kyoto, Japan) equipped with an electron capture detector (ECD) (Fig. 1), and a medium polar col umn (Rtx200 ; Restek Corporation, Bellefronte, PA, USA) with chemically bonded trifluoropropyl methyl polysiloxane as a liquid phase. Experimental samples were prepared by adding sevoflurane into 1 L vacuum sampling bottles (GL Sciences, Tokyo, Japan) filled with indoor air using a micropipette (Eppendorf, Hamburg, Germany). After waiting for the sevoflurane (Maruishi Pharmaceutical, Osaka, Japan) volatilization at room temperature, 20 μL of the sample from the sampling bottle was injected into the gas chromatograph using a micro syringe (Terumo, Tokyo, Japan). Establishment of an ambient air sevoflurane measurement method using ECDGC