Design of a novel anatomical plate for fractures of ulnar coronoid process

Q4 Medicine
F. Bao, Tao Liu, Shijie Kang, Dongsheng Huang, T. Jiang
{"title":"Design of a novel anatomical plate for fractures of ulnar coronoid process","authors":"F. Bao, Tao Liu, Shijie Kang, Dongsheng Huang, T. Jiang","doi":"10.3760/CMA.J.ISSN.1671-7600.2019.10.014","DOIUrl":null,"url":null,"abstract":"Objective \nTo evaluate a self-designed novel anatomical bone plate for fractures of ulnar coronoid process in cadaveric specimens. \n \n \nMethods \nOur database search in the Imaging Center, Qilu Hospital of Shandong University (Qingdao) yielded CT reconstruction images of 45 normal adult elbows (26 males and 19 females) which met our criteria. On the 3D reformatted CT images, sagittal curvature angle of the ulnar coronal process (△1), tangent angle of the coronal process apex to olecranon fossa (△2), projective length (L) and projective height (H) were measured; the transverse width of the coronal process was also measured at 5 mm and 10 mm from the tip (K1 and K2). The minimum value was used for △2° in order to avoid cutting into the joint while the mean value for other parameters. After the shape of the plate and angles of the screws were designed using computer 3D software, a new anatomic plate for coronal process was produced. Five cadaver specimens were used to test the internal fixation of the coronal process with our novel anatomic bone plate. Attachment of the bone plate to the coronal process and screw penetration into the joint cavity were observed by X-ray and 3D CT scanning. \n \n \nResults \n△1 was 45.52°±6.07°, △2 65.25°±7.09° (the minimum value 53.2°), L 52.27±7.78 mm, H 21.62±2.63 mm, K1 16.32±2.22 mm and K2 14.58±2.18 mm. Our new anatomic bone plate was designed based on the above data. X-ray and 3D CT scan after plate internal fixation showed that our self-designed bone plate produced fine attachment and no screws penetrated into the joint. \n \n \nConclusion \nOur new anatomical bone plate may perfectly fit the anatomy of the adult ulnar coronal process in size and shape so that the coronary process can be fully covered and no screws will penetrate into the joint cavity. \n \n \nKey words: \nBone plate; Elbow Joint; Anatomy; Cadaver","PeriodicalId":10145,"journal":{"name":"中华创伤骨科杂志","volume":"21 1","pages":"901-905"},"PeriodicalIF":0.0000,"publicationDate":"2019-10-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华创伤骨科杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/CMA.J.ISSN.1671-7600.2019.10.014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective To evaluate a self-designed novel anatomical bone plate for fractures of ulnar coronoid process in cadaveric specimens. Methods Our database search in the Imaging Center, Qilu Hospital of Shandong University (Qingdao) yielded CT reconstruction images of 45 normal adult elbows (26 males and 19 females) which met our criteria. On the 3D reformatted CT images, sagittal curvature angle of the ulnar coronal process (△1), tangent angle of the coronal process apex to olecranon fossa (△2), projective length (L) and projective height (H) were measured; the transverse width of the coronal process was also measured at 5 mm and 10 mm from the tip (K1 and K2). The minimum value was used for △2° in order to avoid cutting into the joint while the mean value for other parameters. After the shape of the plate and angles of the screws were designed using computer 3D software, a new anatomic plate for coronal process was produced. Five cadaver specimens were used to test the internal fixation of the coronal process with our novel anatomic bone plate. Attachment of the bone plate to the coronal process and screw penetration into the joint cavity were observed by X-ray and 3D CT scanning. Results △1 was 45.52°±6.07°, △2 65.25°±7.09° (the minimum value 53.2°), L 52.27±7.78 mm, H 21.62±2.63 mm, K1 16.32±2.22 mm and K2 14.58±2.18 mm. Our new anatomic bone plate was designed based on the above data. X-ray and 3D CT scan after plate internal fixation showed that our self-designed bone plate produced fine attachment and no screws penetrated into the joint. Conclusion Our new anatomical bone plate may perfectly fit the anatomy of the adult ulnar coronal process in size and shape so that the coronary process can be fully covered and no screws will penetrate into the joint cavity. Key words: Bone plate; Elbow Joint; Anatomy; Cadaver
尺骨冠突骨折解剖钢板的设计
目的探讨自行设计的新型尺冠突骨折解剖钢板在尸体标本中的应用价值。方法在山东大学(青岛)齐鲁医院影像中心检索符合标准的45例正常成人肘部CT重建图像(男26例,女19例)。在三维重建的CT图像上,测量尺冠状突矢状曲率角(△1)、冠状突顶点与鹰嘴窝的切角(△2)、投影长度(L)和投影高度(H);冠状突的横向宽度也在距离尖端5 mm和10 mm处测量(K1和K2)。为避免切入接头,取最小值△2°,其他参数取平均值。利用计算机三维软件对钢板形状和螺钉角度进行设计后,制作出一种新型冠状突解剖钢板。五个尸体标本被用来测试冠状突内固定与我们的新型解剖骨板。通过x线和三维CT扫描观察骨板与冠状突的附着情况和螺钉进入关节腔的情况。结果△1为45.52°±6.07°,△2为65.25°±7.09°(最小值53.2°),L为52.27±7.78 mm, H为21.62±2.63 mm, K1为16.32±2.22 mm, K2为14.58±2.18 mm。我们的新解剖骨板是基于上述数据设计的。钢板内固定后x线及3D CT扫描显示,我们自行设计的接骨板附着良好,无螺钉刺入关节。结论新型解剖骨板在尺寸和形状上与成人尺冠状突解剖结构完全吻合,可以完全覆盖冠状突,避免螺钉穿入关节腔。关键词:接骨板;肘关节;解剖学的;尸体
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.70
自引率
0.00%
发文量
7288
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信