Analyzing the Effects of Soil-Structure Interactions on the Static Response of Onshore Wind Turbine Foundations Using Finite Element Method

IF 1 Q4 ENGINEERING, CIVIL
Amin Motallebiyan, M. Bayat, B. Nadi
{"title":"Analyzing the Effects of Soil-Structure Interactions on the Static Response of Onshore Wind Turbine Foundations Using Finite Element Method","authors":"Amin Motallebiyan, M. Bayat, B. Nadi","doi":"10.22059/CEIJ.2020.281914.1586","DOIUrl":null,"url":null,"abstract":"The use of wind turbines to generate electricity has increased in recent years. One of the most important parts of a wind turbine is the foundation, which should be designed accurately because it is influenced by difference forces. Soil cannot carry tension stress; thus, when a wind turbine foundation is applied eccentricity forces, a gap appears between the soil and foundation. The gap will have no positive effect on the ultimate bearing capacity of the foundation. This must be considered when designing the dimensions of an onshore wind turbine on a spread foundation using finite element software in order to avoid error during analysis. In the current study, a spread foundation of an onshore wind turbine was simulated using ABAQUS and PLAXIS-3D software. Based on the results, the effects of Soil-Structure Interaction (SSI), eccentricity of forces, soil strength parameters and the foundation buried depth on static response of the foundation are discussed. The results indicate that the influence of soil-structure interaction is depend on magnitude of eccentricity of forces and depth of foundation, so that soil-structure interaction has little impact on settlement of foundation when eccentricity of forces is less than 1/6 of the diameter of the foundation and this has important effect when the eccentricity forces at an amount exceeding 1/6 of the diameter of the foundation. In addition, this effect decreases with increasing the foundation buried depth and independent of the soil strength parameters (φ´ and C).","PeriodicalId":43959,"journal":{"name":"Civil Engineering Infrastructures Journal-CEIJ","volume":null,"pages":null},"PeriodicalIF":1.0000,"publicationDate":"2020-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Civil Engineering Infrastructures Journal-CEIJ","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22059/CEIJ.2020.281914.1586","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 5

Abstract

The use of wind turbines to generate electricity has increased in recent years. One of the most important parts of a wind turbine is the foundation, which should be designed accurately because it is influenced by difference forces. Soil cannot carry tension stress; thus, when a wind turbine foundation is applied eccentricity forces, a gap appears between the soil and foundation. The gap will have no positive effect on the ultimate bearing capacity of the foundation. This must be considered when designing the dimensions of an onshore wind turbine on a spread foundation using finite element software in order to avoid error during analysis. In the current study, a spread foundation of an onshore wind turbine was simulated using ABAQUS and PLAXIS-3D software. Based on the results, the effects of Soil-Structure Interaction (SSI), eccentricity of forces, soil strength parameters and the foundation buried depth on static response of the foundation are discussed. The results indicate that the influence of soil-structure interaction is depend on magnitude of eccentricity of forces and depth of foundation, so that soil-structure interaction has little impact on settlement of foundation when eccentricity of forces is less than 1/6 of the diameter of the foundation and this has important effect when the eccentricity forces at an amount exceeding 1/6 of the diameter of the foundation. In addition, this effect decreases with increasing the foundation buried depth and independent of the soil strength parameters (φ´ and C).
用有限元法分析土-结构相互作用对陆上风力发电机基础静力响应的影响
近年来,使用风力涡轮机发电的情况有所增加。风力涡轮机最重要的部件之一是基础,因为它受到不同力的影响,所以应该准确设计。土壤不能承受拉应力;因此,当风力涡轮机基础受到偏心力时,土壤和基础之间会出现间隙。间隙不会对地基的极限承载力产生积极影响。在使用有限元软件设计扩展基础上的陆上风机尺寸时,必须考虑这一点,以避免分析过程中出现错误。在当前的研究中,使用ABAQUS和PLAXIS-3D软件对陆上风机的扩展基础进行了模拟。在此基础上,讨论了土与结构相互作用、力的偏心率、土的强度参数和基础埋深对地基静力响应的影响。结果表明,土-结构相互作用的影响取决于力的偏心度大小和地基深度,使得当力的离心率小于基础直径的1/6时,土-结构相互作用对基础沉降的影响很小,而当离心力的量超过基础直径的1/6时,这具有重要影响。此外,这种影响随着基础埋深的增加而减小,与土壤强度参数(φ´和C)无关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.30
自引率
60.00%
发文量
0
审稿时长
47 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信