Dialysis Shunt Thrombectomy Utilizing a Rotational Thrombectomy Device in Patients with Pseudoaneurysms

A. Webb, K. Zacharias, P. Ciolek, T. Webb, O. Ahmed
{"title":"Dialysis Shunt Thrombectomy Utilizing a Rotational Thrombectomy Device in Patients with Pseudoaneurysms","authors":"A. Webb, K. Zacharias, P. Ciolek, T. Webb, O. Ahmed","doi":"10.4103/AJIR.AJIR_8_20","DOIUrl":null,"url":null,"abstract":"Aims: To assess the safety and efficacy of dialysis shunt thrombectomy utilizing a rotational thrombectomy device in patients with pseudoaneurysms refractory to declot by conventional treatments. Methods: Between July 2016 and August 2019, 34 dialysis shunt thrombectomies were retrospectively examined in 29 individual patients. All patients presented with pseudoaneurysms and clotted accesses that were refractory to angioplasty balloon sweeps (“push–pull”) to restore patency. The Cleaner® rotational thrombectomy device was used as a bail-out in an attempt to restore patency to the clotted shunt. Procedure success, complications, primary patency, primary-assisted patency, secondary patency, average number of shunt pseudoaneurysms, and average pseudoaneurysm size were documented and analyzed. Results: Thirty-three of the 34 (97%) thrombectomies were successful in restoring patency and facilitating same-day hemodialysis. An average of 1.5 pseudoaneurysms were present per patient (range 1–3 pseudoaneurysms, standard deviation [SD] 0.65 pseudoaneurysms), with an average size of 15.0 mm (range 9.4–31.1 mm, SD 4.87 mm). Postprocedural complications occurred in 14.7% of the cases, none of which were definitively device related. Primary patency to the time of data collection was achieved in 29% of the cases, and the average primary patency for these cases was 124.5 days (range 10–946 days, SD 186.9 days). The average primary-assisted patency was 126.8 days (range 1–564 days, SD 169.8 days). Dialysis accesses were eventually abandoned or surgically revised in ten instances, resulting in an average secondary patency of 157.5 days (range 6–712 days, SD 257 days). Conclusions: In patients with pseudoaneurysms, rotational thrombectomy with the Cleaner® device appeared to be a safe and effective option for restoring patency to thrombosed dialysis accesses refractory to standard push–pull techniques with angioplasty balloons.","PeriodicalId":32940,"journal":{"name":"The Arab Journal of Interventional Radiology","volume":"4 1","pages":"087 - 091"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Arab Journal of Interventional Radiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/AJIR.AJIR_8_20","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Aims: To assess the safety and efficacy of dialysis shunt thrombectomy utilizing a rotational thrombectomy device in patients with pseudoaneurysms refractory to declot by conventional treatments. Methods: Between July 2016 and August 2019, 34 dialysis shunt thrombectomies were retrospectively examined in 29 individual patients. All patients presented with pseudoaneurysms and clotted accesses that were refractory to angioplasty balloon sweeps (“push–pull”) to restore patency. The Cleaner® rotational thrombectomy device was used as a bail-out in an attempt to restore patency to the clotted shunt. Procedure success, complications, primary patency, primary-assisted patency, secondary patency, average number of shunt pseudoaneurysms, and average pseudoaneurysm size were documented and analyzed. Results: Thirty-three of the 34 (97%) thrombectomies were successful in restoring patency and facilitating same-day hemodialysis. An average of 1.5 pseudoaneurysms were present per patient (range 1–3 pseudoaneurysms, standard deviation [SD] 0.65 pseudoaneurysms), with an average size of 15.0 mm (range 9.4–31.1 mm, SD 4.87 mm). Postprocedural complications occurred in 14.7% of the cases, none of which were definitively device related. Primary patency to the time of data collection was achieved in 29% of the cases, and the average primary patency for these cases was 124.5 days (range 10–946 days, SD 186.9 days). The average primary-assisted patency was 126.8 days (range 1–564 days, SD 169.8 days). Dialysis accesses were eventually abandoned or surgically revised in ten instances, resulting in an average secondary patency of 157.5 days (range 6–712 days, SD 257 days). Conclusions: In patients with pseudoaneurysms, rotational thrombectomy with the Cleaner® device appeared to be a safe and effective option for restoring patency to thrombosed dialysis accesses refractory to standard push–pull techniques with angioplasty balloons.
利用旋转取栓装置在假性动脉瘤患者中的透析分流取栓
目的:评估使用旋转血栓切除器进行透析分流血栓切除术治疗传统治疗难治性假性动脉瘤的安全性和有效性。方法:在2016年7月至2019年8月期间,对29名患者的34例透析分流血栓切除术进行了回顾性检查。所有患者都出现了假性动脉瘤和阻塞性通路,这些通路对血管成形术球囊扫描(“推拉”)恢复通畅是难治的。Cleaner®旋转血栓切除装置被用作纾困,试图恢复阻塞分流器的通畅性。记录并分析手术成功率、并发症、初次通畅率、初次辅助通畅率、二次通畅率、分流假性动脉瘤的平均数量和平均假性动脉瘤大小。结果:34例血栓切除术中有33例(97%)成功地恢复了通畅性并促进了当天的血液透析。每位患者平均有1.5个假动脉瘤(范围1-3个假动脉,标准差[SD]0.65个假动脉),平均大小为15.0 mm(范围9.4-31.1 mm,标准差4.87 mm)。14.7%的病例发生术后并发症,其中没有一例明确与器械有关。29%的病例在数据收集时实现了一次通畅,这些病例的平均一次通畅期为124.5天(范围为10–946天,SD为186.9天)。初次辅助通畅率平均为126.8天(范围为1-564天,标准差169.8天)。在10例病例中,透析通路最终被放弃或手术修正,导致平均二次通畅157.5天(范围为6-712天,SD 257天)。结论:在假性动脉瘤患者中,使用Cleaner®装置进行旋转血栓切除术似乎是一种安全有效的选择,可以恢复血栓透析通路的通畅性,而血栓透析通路对血管成形术球囊的标准推拉技术是难治的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
18
审稿时长
13 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信