Fernando Augusto Gouvea-Reis, Danniely Carolinne Soares da Silva, Lairton Souza Borja, Patrícia de Oliveira Dias, Jadher Percio, Cassio Peterka, Janaína de Oliveira, Giselle Sodré, Claudia Mendes Feres, Wallace Dos Santos, Fábio Souza, Ana Izabel Passarella Teixeira, Daiani Cristina Cilião-Alves, Gustavo Adolfo Sierra Romero, Elza Ferreira Noronha, Julio Croda, Rodrigo Haddad, Walter Massa Ramalho, Camile de Moraes, Wildo Navegantes de Araújo
{"title":"SARS CoV-2 seroprevalence and diagnostic accuracy during a COVID-19 outbreak in a major penitentiary complex in Brazil, June to July 2020.","authors":"Fernando Augusto Gouvea-Reis, Danniely Carolinne Soares da Silva, Lairton Souza Borja, Patrícia de Oliveira Dias, Jadher Percio, Cassio Peterka, Janaína de Oliveira, Giselle Sodré, Claudia Mendes Feres, Wallace Dos Santos, Fábio Souza, Ana Izabel Passarella Teixeira, Daiani Cristina Cilião-Alves, Gustavo Adolfo Sierra Romero, Elza Ferreira Noronha, Julio Croda, Rodrigo Haddad, Walter Massa Ramalho, Camile de Moraes, Wildo Navegantes de Araújo","doi":"10.1108/IJPH-08-2021-0083","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aims to estimate the overall SARS-CoV-2 seroprevalence and evaluate the accuracy of an antibody rapid test compared to a reference serological assay during a COVID-19 outbreak in a prison complex housing over 13,000 prisoners in Brasília.</p><p><strong>Design/methodology/approach: </strong>The authors obtained a randomized, stratified representative sample of each prison unit and conducted a repeated serosurvey among prisoners between June and July 2020, using a lateral-flow immunochromatographic assay (LFIA). Samples were also retested using a chemiluminescence enzyme immunoassay (CLIA) to compare SARS-CoV-2 seroprevalence and 21-days incidence, as well as to estimate the overall infection fatality rate (IFR) and determine the diagnostic accuracy of the LFIA test.</p><p><strong>Findings: </strong>This study identified 485 eligible individuals and enrolled 460 participants. Baseline and 21-days follow-up seroprevalence were estimated at 52.0% (95% CI 44.9-59.0) and 56.7% (95% CI 48.2-65.3) with LFIA; and 80.7% (95% CI 74.1-87.3) and 81.1% (95% CI 74.4-87.8) with CLIA, with an overall IFR of 0.02%. There were 78.2% (95% CI 66.7-89.7) symptomatic individuals among the positive cases. Sensitivity and specificity of LFIA were estimated at 43.4% and 83.3% for IgM; 46.5% and 91.5% for IgG; and 59.1% and 77.3% for combined tests.</p><p><strong>Originality/value: </strong>The authors found high seroprevalence of anti-SARS-CoV-2 antibodies within the prison complex. The occurrence of asymptomatic infection highlights the importance of periodic mass testing in addition to case-finding of symptomatic individuals; however, the field performance of LFIA tests should be validated. This study recommends that vaccination strategies consider the inclusion of prisoners and prison staff in priority groups.</p>","PeriodicalId":45561,"journal":{"name":"International Journal of Prisoner Health","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2023-05-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Prisoner Health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1108/IJPH-08-2021-0083","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: This study aims to estimate the overall SARS-CoV-2 seroprevalence and evaluate the accuracy of an antibody rapid test compared to a reference serological assay during a COVID-19 outbreak in a prison complex housing over 13,000 prisoners in Brasília.
Design/methodology/approach: The authors obtained a randomized, stratified representative sample of each prison unit and conducted a repeated serosurvey among prisoners between June and July 2020, using a lateral-flow immunochromatographic assay (LFIA). Samples were also retested using a chemiluminescence enzyme immunoassay (CLIA) to compare SARS-CoV-2 seroprevalence and 21-days incidence, as well as to estimate the overall infection fatality rate (IFR) and determine the diagnostic accuracy of the LFIA test.
Findings: This study identified 485 eligible individuals and enrolled 460 participants. Baseline and 21-days follow-up seroprevalence were estimated at 52.0% (95% CI 44.9-59.0) and 56.7% (95% CI 48.2-65.3) with LFIA; and 80.7% (95% CI 74.1-87.3) and 81.1% (95% CI 74.4-87.8) with CLIA, with an overall IFR of 0.02%. There were 78.2% (95% CI 66.7-89.7) symptomatic individuals among the positive cases. Sensitivity and specificity of LFIA were estimated at 43.4% and 83.3% for IgM; 46.5% and 91.5% for IgG; and 59.1% and 77.3% for combined tests.
Originality/value: The authors found high seroprevalence of anti-SARS-CoV-2 antibodies within the prison complex. The occurrence of asymptomatic infection highlights the importance of periodic mass testing in addition to case-finding of symptomatic individuals; however, the field performance of LFIA tests should be validated. This study recommends that vaccination strategies consider the inclusion of prisoners and prison staff in priority groups.