Behavior of Auxetic Steel Wire RC Columns Exposed to Elevated Temperature

IF 1.4 4区 工程技术 Q3 ENGINEERING, CIVIL
R. Al-Rousan
{"title":"Behavior of Auxetic Steel Wire RC Columns Exposed to Elevated Temperature","authors":"R. Al-Rousan","doi":"10.1590/1679-78256422","DOIUrl":null,"url":null,"abstract":"TWENTY-FOUR RECTANGULAR RC COLUMN SPECIMENS, CONSTRUCTED AT 1/3 SCALE, WERE TESTED UNDER AXIAL LOADING TO INVESTIGATE THE USE OF ASWM (ONE, TWO, THREE, FOUR, AND FIVE LAYERS) EXPOSED TO ELEVATED TEMPERATURES. SIX OF THE COLUMN SPECIMENS WERE SUBJECTED TO LABORATORY TEMPERATURE (CONTROL OR UN-DAMAGED SPECIMENS) OF 23OC. EIGHTEEN OF THE COLUMN SPECIMENS WERE SUBJECTED TO ELEVATED TEMPERATURES (SIX COLUMNS AT 250OC, SIX COLUMNS AT 500OC, AND SIX COLUMNS AT 750OC) FOR 2 HR. THE OBTAINED RESULTS CLEARLY SHOWED THAT EACH AXIAL LOAD RESISTANCE, TOUGHNESS, AND STIFFNESS WERE ALL NEGATIVELY AFFECTED BY ESCALATED TEMPERATURE DEGREES. ALSO, THE CONFINEMENT EFFECTIVENESS IN TERMS OF THE ULTIMATE LOAD WAS DECREASED WITH THE INCREASE IN CONCRETE COMPRESSIVE STRENGTH (UN-DAMAGED). THE NUMBER OF ASWM LAYERS SIGNIFICANTLY INFLUENCED THE DUCTILITY, ENERGY ABSORPTION, AND ULTIMATE LOAD IMPROVEMENT PERCENTAGE. THE NUMBER OF THE ASWM LAYERS CONSIDERABLY ENHANCED THE DUCTILITY UP TO A CERTAIN NUMBER OF ERECTED LAYERS; HOWEVER, ADDING MORE LAYERS HAD NO APPARENT EFFECT.","PeriodicalId":18192,"journal":{"name":"Latin American Journal of Solids and Structures","volume":"18 1","pages":"1-15"},"PeriodicalIF":1.4000,"publicationDate":"2021-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Latin American Journal of Solids and Structures","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1590/1679-78256422","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 4

Abstract

TWENTY-FOUR RECTANGULAR RC COLUMN SPECIMENS, CONSTRUCTED AT 1/3 SCALE, WERE TESTED UNDER AXIAL LOADING TO INVESTIGATE THE USE OF ASWM (ONE, TWO, THREE, FOUR, AND FIVE LAYERS) EXPOSED TO ELEVATED TEMPERATURES. SIX OF THE COLUMN SPECIMENS WERE SUBJECTED TO LABORATORY TEMPERATURE (CONTROL OR UN-DAMAGED SPECIMENS) OF 23OC. EIGHTEEN OF THE COLUMN SPECIMENS WERE SUBJECTED TO ELEVATED TEMPERATURES (SIX COLUMNS AT 250OC, SIX COLUMNS AT 500OC, AND SIX COLUMNS AT 750OC) FOR 2 HR. THE OBTAINED RESULTS CLEARLY SHOWED THAT EACH AXIAL LOAD RESISTANCE, TOUGHNESS, AND STIFFNESS WERE ALL NEGATIVELY AFFECTED BY ESCALATED TEMPERATURE DEGREES. ALSO, THE CONFINEMENT EFFECTIVENESS IN TERMS OF THE ULTIMATE LOAD WAS DECREASED WITH THE INCREASE IN CONCRETE COMPRESSIVE STRENGTH (UN-DAMAGED). THE NUMBER OF ASWM LAYERS SIGNIFICANTLY INFLUENCED THE DUCTILITY, ENERGY ABSORPTION, AND ULTIMATE LOAD IMPROVEMENT PERCENTAGE. THE NUMBER OF THE ASWM LAYERS CONSIDERABLY ENHANCED THE DUCTILITY UP TO A CERTAIN NUMBER OF ERECTED LAYERS; HOWEVER, ADDING MORE LAYERS HAD NO APPARENT EFFECT.
钢筋混凝土柱在高温下的性能
在轴向荷载作用下,对24个1/3比例的矩形RC柱试件进行了试验,以研究ASWM(一层、二层、三层、四层和五层)在高温下的使用。其中6个柱状试样的实验室温度(对照或未损伤试样)为23OC。18个柱体试样(6个柱体在250OC下,6个柱状物在500OC下,以及6个柱形物在750OC下)在高温下放置2小时。所获得的结果清楚地表明,每个轴向载荷阻力、韧性和刚度都受到温度升高的负向影响。同时,随着混凝土抗压强度(未损伤)的增加,极限荷载的约束有效性降低。ASWM层数对延性、能量吸收和极限荷载改善率有显著影响。ASWM层的数量显著提高了延展性,达到一定数量的竖立层;然而,增加更多的层没有明显的效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.80
自引率
8.30%
发文量
37
审稿时长
>12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信