The Performance of Sensitivity-Maps Method in Reconstructing Low Contrast and Multi-Contrast Objects for Microwave Imaging Applications

IF 1.7 Q3 COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS
Basari, Syahrul Ramdani
{"title":"The Performance of Sensitivity-Maps Method in Reconstructing Low Contrast and Multi-Contrast Objects for Microwave Imaging Applications","authors":"Basari, Syahrul Ramdani","doi":"10.3991/ijoe.v19i08.38665","DOIUrl":null,"url":null,"abstract":"The microwave imaging system for breast tumor/cancer detection requires high sensitivity to detect abnormal tissue that has little contrast in high-density breasts. This paper proposes a qualitative microwave imaging system simulation based on inverse scattering using the sensitivity-maps method. This method utilizes two measurement types for system calibration: a reference object as a scatterer-free background and a calibration object to obtain the system's impulse response. The object under test (OUT) consists of an object with low dielectric contrast and a phantom with multiple low dielectric contrasts (multi-contrast). Reconstruction is carried out on three types of S-parameter measurement data, namely S_11,〖 S〗_21, and a combination of both. S-parameters are measured at several frequencies, which are 3, 10, 14, 15, 16, 20 GHz, and the combination of all those frequencies (multifrequency). Reconstructed images show that the system is capable of reconstructing dielectric objects accurately. Quantitatively, the results show that the multifrequency S_21 measurement yields the best image quality with relative root mean squared error (RRMSE) values of 0.1272 and structural similarity index (SSIM) of 0.9076. The designed imaging system also successfully reconstructs multi-contrast phantom accurately with RRMSE of 0.1434 and SSIM of 0.4609.","PeriodicalId":36900,"journal":{"name":"International Journal of Online and Biomedical Engineering","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2023-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Online and Biomedical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3991/ijoe.v19i08.38665","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
引用次数: 0

Abstract

The microwave imaging system for breast tumor/cancer detection requires high sensitivity to detect abnormal tissue that has little contrast in high-density breasts. This paper proposes a qualitative microwave imaging system simulation based on inverse scattering using the sensitivity-maps method. This method utilizes two measurement types for system calibration: a reference object as a scatterer-free background and a calibration object to obtain the system's impulse response. The object under test (OUT) consists of an object with low dielectric contrast and a phantom with multiple low dielectric contrasts (multi-contrast). Reconstruction is carried out on three types of S-parameter measurement data, namely S_11,〖 S〗_21, and a combination of both. S-parameters are measured at several frequencies, which are 3, 10, 14, 15, 16, 20 GHz, and the combination of all those frequencies (multifrequency). Reconstructed images show that the system is capable of reconstructing dielectric objects accurately. Quantitatively, the results show that the multifrequency S_21 measurement yields the best image quality with relative root mean squared error (RRMSE) values of 0.1272 and structural similarity index (SSIM) of 0.9076. The designed imaging system also successfully reconstructs multi-contrast phantom accurately with RRMSE of 0.1434 and SSIM of 0.4609.
灵敏度图方法在微波成像低对比度和多对比度目标重建中的性能
用于乳腺肿瘤/癌症检测的微波成像系统需要高灵敏度来检测高密度乳腺中对比度低的异常组织。提出了一种基于逆散射的灵敏度图定性微波成像系统仿真方法。该方法利用两种测量类型进行系统校准:一种是作为无散射背景的参考对象,另一种是获得系统脉冲响应的校准对象。被测对象(OUT)由低介电对比度的对象和具有多个低介电对比度的幻像(multi-contrast)组成。对S_11、〖S〗_21以及两者的组合三种S参数测量数据进行重构。s参数在3、10、14、15、16、20 GHz以及所有这些频率的组合(多频)下测量。重建图像表明,该系统能够准确地重建介电物体。定量结果表明,多频S_21测量得到的图像质量最佳,相对均方根误差(RRMSE)为0.1272,结构相似指数(SSIM)为0.9076。所设计的成像系统也成功地准确重建了多对比度幻像,RRMSE为0.1434,SSIM为0.4609。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.00
自引率
46.20%
发文量
143
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信