From state-of-the-art ventilation to closed loop ventilation

A. Schibler, M. van der Staay, Christian Remus
{"title":"From state-of-the-art ventilation to closed loop ventilation","authors":"A. Schibler, M. van der Staay, Christian Remus","doi":"10.53097/jmv.10054","DOIUrl":null,"url":null,"abstract":"Recent emphasis on energy load delivered during each ventilatory breath has opened a new insight to reduce harmful ventilatory induced lung injury, but no robust clinical evidence of patient benefit produced yet. Closed loop ventilation is a strategy to adjust respiratory support using physiological feedback data obtained for each delivered cycle of respiratory support. Dependent on the model assumption used, closed loop ventilation aims to identify the ideal combination of tidal volume size, reduced driving pressure or respiratory frequency ultimately reducing the energy loading of the lung. This review aims to discuss the current state-of-the-art ventilation concepts and their integration in closed loop ventilation.","PeriodicalId":73813,"journal":{"name":"Journal of mechanical ventilation","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of mechanical ventilation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.53097/jmv.10054","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Recent emphasis on energy load delivered during each ventilatory breath has opened a new insight to reduce harmful ventilatory induced lung injury, but no robust clinical evidence of patient benefit produced yet. Closed loop ventilation is a strategy to adjust respiratory support using physiological feedback data obtained for each delivered cycle of respiratory support. Dependent on the model assumption used, closed loop ventilation aims to identify the ideal combination of tidal volume size, reduced driving pressure or respiratory frequency ultimately reducing the energy loading of the lung. This review aims to discuss the current state-of-the-art ventilation concepts and their integration in closed loop ventilation.
从最先进的通风到闭环通风
最近强调的能量负荷传递在每次通气呼吸打开了一个新的见解,以减少有害的通气引起的肺损伤,但没有强有力的临床证据,病人的利益产生尚未。闭环通气是一种利用每个呼吸支持周期获得的生理反馈数据来调节呼吸支持的策略。根据所使用的模型假设,闭环通气旨在确定潮气量大小、降低驱动压力或呼吸频率的理想组合,最终降低肺的能量负荷。本综述旨在讨论当前最先进的通风概念及其在闭环通风中的集成。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信