Estimation of aquatic dilution factor for liquid effluent discharges from Kaiga Generating Station using tritium as a tracer

T. Reji, R. Joshi, T. Ajith, Sanyam Jain, M. Vishnu, I. Saradhi, A. Vinodkumar
{"title":"Estimation of aquatic dilution factor for liquid effluent discharges from Kaiga Generating Station using tritium as a tracer","authors":"T. Reji, R. Joshi, T. Ajith, Sanyam Jain, M. Vishnu, I. Saradhi, A. Vinodkumar","doi":"10.4103/rpe.rpe_37_22","DOIUrl":null,"url":null,"abstract":"Very low-level radioactive liquid effluents much below the approved discharge limits are discharged to Kadra reservoir after dilution with condenser cooling water at Kaiga Generating Station. In addition, further dilution occurs from the discharge point to the nearest public utilization point in Kadra reservoir (Hartuga). The dilution obtained in Kadra reservoir is estimated by simultaneous measurements of tritium at the discharge point and at Hartuga. The on-site measurement indicates a dilution factor of 12.2 ± 2.4 for tritium. A dilution factor of 13.3 ± 3.4 was obtained using aquatic dispersion model.","PeriodicalId":32488,"journal":{"name":"Radiation Protection and Environment","volume":"45 1","pages":"127 - 130"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation Protection and Environment","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/rpe.rpe_37_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Very low-level radioactive liquid effluents much below the approved discharge limits are discharged to Kadra reservoir after dilution with condenser cooling water at Kaiga Generating Station. In addition, further dilution occurs from the discharge point to the nearest public utilization point in Kadra reservoir (Hartuga). The dilution obtained in Kadra reservoir is estimated by simultaneous measurements of tritium at the discharge point and at Hartuga. The on-site measurement indicates a dilution factor of 12.2 ± 2.4 for tritium. A dilution factor of 13.3 ± 3.4 was obtained using aquatic dispersion model.
用氚作示踪剂估算海贺电站液体出水水中稀释系数
远低于批准排放限值的极低放射性液体流出物经Kaiga发电站的冷凝器冷却水稀释后排放到Kadra水库。此外,从排放点到Kadra水库(Hartuga)最近的公共利用点发生进一步稀释。通过在排放点和Hartuga同时测量氚来估计Kadra水库中获得的稀释。现场测量表明,氚的稀释系数为12.2±2.4。采用水生分散模型得到的稀释系数为13.3±3.4。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
15 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信