R. Ridwan, A. R. H. Rashmizal, M. Adenan, M. Mazlina
{"title":"SEPARATION OF L-ARGININE AND L-CITRULLINE IN RED AND YELLOW CRIMSON WATERMELON (Citrullus lanatus) JUICES EXTRACT USING HPLC GRADIENT MODE","authors":"R. Ridwan, A. R. H. Rashmizal, M. Adenan, M. Mazlina","doi":"10.17576/MJAS-2018-2205-06","DOIUrl":null,"url":null,"abstract":"Watermelon (Citrullus lanatus) is a nutritious fruit that has attracted scientific interest due to its phytonutrient content including carotenoids and amino acids. Watermelon juice is the richest known source of amino acids including L-arginine and L-citrulline. For a complete separation of amino acids in watermelon juices, a gradient mode of reverse phase high performance liquid chromatography (RP-HPLC) with UV detection was utilised owing to its supremacy over isocratic mode. This present study was aimed at achieving good separation of chromatography profiles and baseline between L-arginine and L-citrulline in red and yellow crimson watermelon juice extract. The edible parts of watermelons were juiced, stored at – 80 C and freeze dried to obtain dried juice powder. Samples were analysed by gradient mode of RP-HPLC using 0.1% orthophosphoric acid in water (v/v) and acetonitrile as mobile phase A and B. The chromatograph separation was performed using Gemini C18 column at a flow rate of 1.0 mL/min, maintained temperature at 25 C while detection was made at four different wavelengths; 195 nm, 200 nm, 207 nm and 210 nm with total analysis time of 35 min. Excellent chromatographic separation was achieved at conditions of gradient elution (0%B 95%B, 0-18 minutes and 95%B, 18-23 minutes, 95%B-0%B, 23-25 minutes, 0%B, 25-35 minutes) with baseline between L-arginine and L-citrulline in both watermelon juice extracts. The gradient mode used in this RP-HPLC successfully achieved efficient separation of chromatographic profile for amino acids, L-arginine and L-citrulline in the red and yellow crimson watermelon juice extracts.","PeriodicalId":39007,"journal":{"name":"Malaysian Journal of Analytical Sciences","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2018-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Malaysian Journal of Analytical Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17576/MJAS-2018-2205-06","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Chemistry","Score":null,"Total":0}
引用次数: 1
Abstract
Watermelon (Citrullus lanatus) is a nutritious fruit that has attracted scientific interest due to its phytonutrient content including carotenoids and amino acids. Watermelon juice is the richest known source of amino acids including L-arginine and L-citrulline. For a complete separation of amino acids in watermelon juices, a gradient mode of reverse phase high performance liquid chromatography (RP-HPLC) with UV detection was utilised owing to its supremacy over isocratic mode. This present study was aimed at achieving good separation of chromatography profiles and baseline between L-arginine and L-citrulline in red and yellow crimson watermelon juice extract. The edible parts of watermelons were juiced, stored at – 80 C and freeze dried to obtain dried juice powder. Samples were analysed by gradient mode of RP-HPLC using 0.1% orthophosphoric acid in water (v/v) and acetonitrile as mobile phase A and B. The chromatograph separation was performed using Gemini C18 column at a flow rate of 1.0 mL/min, maintained temperature at 25 C while detection was made at four different wavelengths; 195 nm, 200 nm, 207 nm and 210 nm with total analysis time of 35 min. Excellent chromatographic separation was achieved at conditions of gradient elution (0%B 95%B, 0-18 minutes and 95%B, 18-23 minutes, 95%B-0%B, 23-25 minutes, 0%B, 25-35 minutes) with baseline between L-arginine and L-citrulline in both watermelon juice extracts. The gradient mode used in this RP-HPLC successfully achieved efficient separation of chromatographic profile for amino acids, L-arginine and L-citrulline in the red and yellow crimson watermelon juice extracts.