DECREASING OF COD AND TSS FROM LAUNDRY WASTE USES ALUMINUM (Al) AND COPPER (Cu) ELECTRODES IN THE ELECTROCOAGULATION METHOD

Mirna Desyderia Sumawan
{"title":"DECREASING OF COD AND TSS FROM LAUNDRY WASTE USES ALUMINUM (Al) AND COPPER (Cu) ELECTRODES IN THE ELECTROCOAGULATION METHOD","authors":"Mirna Desyderia Sumawan","doi":"10.30872/jkm.v18i2.737","DOIUrl":null,"url":null,"abstract":"A research about reduction of COD and TSS from laundry waste with Electrocoagulation method using Al and Cu electrodes in COD and TSS reduction  parameters has been done. In this research, the voltage and optimum time determited based on occurred in electrocoagulation process. The determination of COD and TSS in the contact time was 60 minutes with the value of COD was 90.5645% and TSS 63.7279%. The value of voltage optimum was 12 Volt, obtain COD was 90.2392% and TSS 60.7052%.","PeriodicalId":31725,"journal":{"name":"Jurnal Kimia Mulawarman","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-05-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Kimia Mulawarman","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30872/jkm.v18i2.737","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A research about reduction of COD and TSS from laundry waste with Electrocoagulation method using Al and Cu electrodes in COD and TSS reduction  parameters has been done. In this research, the voltage and optimum time determited based on occurred in electrocoagulation process. The determination of COD and TSS in the contact time was 60 minutes with the value of COD was 90.5645% and TSS 63.7279%. The value of voltage optimum was 12 Volt, obtain COD was 90.2392% and TSS 60.7052%.
摘要电絮凝法采用铝(Al)和铜(Cu)电极降低洗衣垃圾中的COD和TSS
研究了铝、铜电极电凝聚法降低洗衣废水中COD和TSS的工艺参数。在本研究中,根据电凝过程中发生的情况确定了电压和最佳时间。接触时间为60min时COD和TSS的测定,COD值为90.5645%,TSS值为63.7279%。最佳电压值为12V,得到COD为90.2392%,TSS为60.7052%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
3
审稿时长
16 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信