Suhu Pemanas Sampel Optimal Untuk Klasifikasi Teh Hitam Menggunakan Electronic Nose

Danang Lelono, K. Triyana
{"title":"Suhu Pemanas Sampel Optimal Untuk Klasifikasi Teh Hitam Menggunakan Electronic Nose","authors":"Danang Lelono, K. Triyana","doi":"10.22146/IJEIS.39683","DOIUrl":null,"url":null,"abstract":" The optimization of heating temperature of black tea samples for the measurement of aroma with electronic nose (e-nose) has been successfully performed. Sample heating is done because black tea has a low aroma intensity and easily lost. However, the selection of such temperature should be selective because it can result in damage to the aroma of the sample. Therefore, temperature optimization needs to be done so that the resulting sensor response comes from the transformation of the undamaged aroma.The method used to obtain the optimum heating temperature by analyzing the sensor response of the aroma transformation that is captured by e-nose. Consistency and pattern changes formed from the sensor response are used as a comparison of optimal heating temperature selection. The measured sample varied in temperature (30 - 60 °C) so that the resulting sensor response was observed. Change in patterns indicate the aroma has been burning. After optimal temperature is obtained then black tea (50 gr) Broken Orange Pokoe, Broken Pokoe II and Bohea with a total sample of 300 bags were measured with e-nose. For further analysis, the result of classification by method of Principal Component Analysis (PCA) as proof of sample heating temperature optimization successfully done.The experimental results show optimal sample heating for black tea 3 quality 40 - 45 °C. After then with the third PCA the sample can be classified up to 92.5% of the total data variant. This indicates the aroma of tea is relatively constant and there is no pattern change.","PeriodicalId":31590,"journal":{"name":"IJEIS Indonesian Journal of Electronics and Instrumentation Systems","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IJEIS Indonesian Journal of Electronics and Instrumentation Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22146/IJEIS.39683","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

 The optimization of heating temperature of black tea samples for the measurement of aroma with electronic nose (e-nose) has been successfully performed. Sample heating is done because black tea has a low aroma intensity and easily lost. However, the selection of such temperature should be selective because it can result in damage to the aroma of the sample. Therefore, temperature optimization needs to be done so that the resulting sensor response comes from the transformation of the undamaged aroma.The method used to obtain the optimum heating temperature by analyzing the sensor response of the aroma transformation that is captured by e-nose. Consistency and pattern changes formed from the sensor response are used as a comparison of optimal heating temperature selection. The measured sample varied in temperature (30 - 60 °C) so that the resulting sensor response was observed. Change in patterns indicate the aroma has been burning. After optimal temperature is obtained then black tea (50 gr) Broken Orange Pokoe, Broken Pokoe II and Bohea with a total sample of 300 bags were measured with e-nose. For further analysis, the result of classification by method of Principal Component Analysis (PCA) as proof of sample heating temperature optimization successfully done.The experimental results show optimal sample heating for black tea 3 quality 40 - 45 °C. After then with the third PCA the sample can be classified up to 92.5% of the total data variant. This indicates the aroma of tea is relatively constant and there is no pattern change.
利用电子鼻进行红茶分类的最佳样品加热
成功地对红茶样品的加热温度进行了优化,并应用电子鼻法测定了红茶样品的香气。样品加热是因为红茶的香气强度低,容易丢失。然而,这种温度的选择应该是有选择性的,因为它会导致样品香气的破坏。因此,需要对温度进行优化,使传感器的响应来自于未损坏的香气的转化。该方法通过分析电子鼻捕捉到的香气转化的传感器响应来获得最佳加热温度。从传感器响应形成的一致性和模式变化被用作最佳加热温度选择的比较。被测样品的温度变化(30 - 60°C),因此可以观察到传感器的响应。图案的变化表明香味一直在燃烧。在获得最佳温度后,用电子鼻对红茶(50克)破橙Pokoe、破Pokoe II和破黑茶共300袋进行了测量。为了进一步分析,用主成分分析(PCA)方法进行分类的结果,作为样品加热温度优化成功的证明。实验结果表明,3级红茶的最佳样品加热温度为40 ~ 45℃。之后,用第三个PCA样本可以分类到92.5%的总数据变体。这表明茶的香气是相对恒定的,没有模式变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信