{"title":"Sensitive Method for LC Analysis of Therapeutic Monoclonal Antibodies Using a Centrifugal Filtration Device with Adsorption Suppression Treatment","authors":"Y. Shibata, Tomohiro Yamada, Eiji Sugiyama, H. Mizuno, K. Todoroki","doi":"10.15583/jpchrom.2020.016","DOIUrl":null,"url":null,"abstract":"Herein, we report an intact LC–native fluorescence analysis method for therapeutic monoclonal antibodies (mAbs) based on a centrifugal filtration device with adsorption suppression treatment. Coating the centrifugal filtration device with MPC monomer suppressed the non-specific adsorption of mAbs, especially in the low concentration range; trastuzumab could be quantitatively and sensitively analyzed in the 0.2–10 μg/mL range. In this analysis, the average concentration factor over the entire concentration range was approximately 25 times. The other mAbs (bevacizumab, rituximab, nivolumab) also showed good linearity with R 2 ≥ 0.996, and the average concentration factors were similar to that obtained for trastuzumab. This method can potentially be used in combination with affinity purification for simple and sensitive bioanalysis.","PeriodicalId":91226,"journal":{"name":"Chromatography (Basel)","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chromatography (Basel)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15583/jpchrom.2020.016","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Herein, we report an intact LC–native fluorescence analysis method for therapeutic monoclonal antibodies (mAbs) based on a centrifugal filtration device with adsorption suppression treatment. Coating the centrifugal filtration device with MPC monomer suppressed the non-specific adsorption of mAbs, especially in the low concentration range; trastuzumab could be quantitatively and sensitively analyzed in the 0.2–10 μg/mL range. In this analysis, the average concentration factor over the entire concentration range was approximately 25 times. The other mAbs (bevacizumab, rituximab, nivolumab) also showed good linearity with R 2 ≥ 0.996, and the average concentration factors were similar to that obtained for trastuzumab. This method can potentially be used in combination with affinity purification for simple and sensitive bioanalysis.
采用吸附抑制处理的离心过滤装置进行治疗性单克隆抗体LC分析的灵敏方法
在此,我们报告了一种基于吸附抑制处理的离心过滤装置的完整lc -天然荧光分析治疗性单克隆抗体(mab)的方法。用MPC单体包覆离心过滤装置抑制了单克隆抗体的非特异性吸附,特别是在低浓度范围内;曲妥珠单抗在0.2 ~ 10 μg/mL范围内均可定量、灵敏分析。在本分析中,整个浓度范围内的平均浓度因子约为25倍。其他单抗(贝伐单抗、利妥昔单抗、纳沃单抗)也表现出良好的线性关系,r2≥0.996,平均浓度因子与曲妥珠单抗相似。该方法可与亲和纯化相结合,用于简单、灵敏的生物分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信