An ion beam system for calibration of space low-energy ion detectors

IF 0.5 4区 物理与天体物理 Q4 ASTRONOMY & ASTROPHYSICS
Shi Guifen, Lian Yiren, Miao Bin, Liu Kai, Hao Xinjun, Pan Zonghao, G. Meng
{"title":"An ion beam system for calibration of space low-energy ion detectors","authors":"Shi Guifen, Lian Yiren, Miao Bin, Liu Kai, Hao Xinjun, Pan Zonghao, G. Meng","doi":"10.1515/astro-2022-0225","DOIUrl":null,"url":null,"abstract":"Abstract Low-energy ion detection in space is one of the most important interests of space exploration. An accurate calibration of this type of instrument is necessary to ensure the effectiveness and scientificness of the obtained data. And the ion source is the most critical equipment in a calibration facility. In this study, an ion beam system based on Kaufman ion source is designed, which can meet the ground calibration of space low-energy ion detection instrument in the low-energy range of 100–1,000 eV. The experimental research shows that when the beam intensity of the ion source is about 100 mA, the Faraday Cup collects about 1 mA of current, and the generated ion beam fluctuates less than 5% within 60 min, which can meet the ground calibration requirements of space low-energy ion detection instruments.","PeriodicalId":19514,"journal":{"name":"Open Astronomy","volume":"32 1","pages":""},"PeriodicalIF":0.5000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open Astronomy","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1515/astro-2022-0225","RegionNum":4,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ASTRONOMY & ASTROPHYSICS","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Low-energy ion detection in space is one of the most important interests of space exploration. An accurate calibration of this type of instrument is necessary to ensure the effectiveness and scientificness of the obtained data. And the ion source is the most critical equipment in a calibration facility. In this study, an ion beam system based on Kaufman ion source is designed, which can meet the ground calibration of space low-energy ion detection instrument in the low-energy range of 100–1,000 eV. The experimental research shows that when the beam intensity of the ion source is about 100 mA, the Faraday Cup collects about 1 mA of current, and the generated ion beam fluctuates less than 5% within 60 min, which can meet the ground calibration requirements of space low-energy ion detection instruments.
一种用于空间低能离子探测器标定的离子束系统
摘要空间低能离子探测是空间探测的重要研究方向之一。为了确保所获得数据的有效性和科学性,有必要对这类仪器进行准确的校准。离子源是校准设施中最关键的设备。本研究设计了一种基于考夫曼离子源的离子束系统,该系统可以满足空间低能离子探测仪器在100–1000低能范围内的地面校准 实验研究表明,当离子源的束流强度约为100 mA,法拉第杯收集大约1 电流mA,产生的离子束在60内波动小于5% min,可以满足空间低能离子探测仪器的地面校准要求。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Open Astronomy
Open Astronomy Physics and Astronomy-Astronomy and Astrophysics
CiteScore
1.30
自引率
14.30%
发文量
37
审稿时长
16 weeks
期刊介绍: The journal disseminates research in both observational and theoretical astronomy, astrophysics, solar physics, cosmology, galactic and extragalactic astronomy, high energy particles physics, planetary science, space science and astronomy-related astrobiology, presenting as well the surveys dedicated to astronomical history and education.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信