Surgical Technique for Sphinkeeper® Implantation.

IF 0.8 Q4 SURGERY
Christopher Dawoud, Daniel Moritz Felsenreich, Felix Harpain, Stefan Riss
{"title":"Surgical Technique for Sphinkeeper® Implantation.","authors":"Christopher Dawoud, Daniel Moritz Felsenreich, Felix Harpain, Stefan Riss","doi":"10.52198/23.STI.43.GS1712","DOIUrl":null,"url":null,"abstract":"<p><p>Fecal incontinence is a distressing condition characterized by the involuntary loss of solid and liquid stool and gas, It affects a significant proportion of the general population, with a reported prevalence ranging from 1% to 20%. Despite its considerable impact on quality of life, therapeutic options for fecal incontinence remain limited. Current treatment modalities for fecal incontinence include conservative approaches such as dietary modifications, pelvic floor exercises, and pharmacotherapy. Surgical interventions, including sphincteroplasty or sacral nerve stimulation, may be considered in more severe cases. Recently, THD Labs (THD S.p.A. Correggio (RE), Italy) introduced the Gatekeeper® as a novel device that supports the implantation of up to four solid prostheses into the intersphincteric groove. Early data were promising, with success rates above 50% and only a few perioperative complications. Subsequently, Gatekeeper® was modified by increasing the length and number (up to 10) of prostheses, and renamed Sphinkeeper® (THD). With this device, nine to 10 small incisions measuring 2 mm are made at a distance of 2-3 cm from the anus. The intersphincteric space is accessed using the delivery system, and positioning is verified through endoanal ultrasound. This procedure is repeated for all 10 prostheses placed around the entire circumference. The Sphinkeeper® offers the potential to improve the management of fecal incontinence, and offers patients a less-invasive alternative to traditional surgical approaches.</p>","PeriodicalId":22194,"journal":{"name":"Surgical technology international","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2023-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical technology international","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52198/23.STI.43.GS1712","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Fecal incontinence is a distressing condition characterized by the involuntary loss of solid and liquid stool and gas, It affects a significant proportion of the general population, with a reported prevalence ranging from 1% to 20%. Despite its considerable impact on quality of life, therapeutic options for fecal incontinence remain limited. Current treatment modalities for fecal incontinence include conservative approaches such as dietary modifications, pelvic floor exercises, and pharmacotherapy. Surgical interventions, including sphincteroplasty or sacral nerve stimulation, may be considered in more severe cases. Recently, THD Labs (THD S.p.A. Correggio (RE), Italy) introduced the Gatekeeper® as a novel device that supports the implantation of up to four solid prostheses into the intersphincteric groove. Early data were promising, with success rates above 50% and only a few perioperative complications. Subsequently, Gatekeeper® was modified by increasing the length and number (up to 10) of prostheses, and renamed Sphinkeeper® (THD). With this device, nine to 10 small incisions measuring 2 mm are made at a distance of 2-3 cm from the anus. The intersphincteric space is accessed using the delivery system, and positioning is verified through endoanal ultrasound. This procedure is repeated for all 10 prostheses placed around the entire circumference. The Sphinkeeper® offers the potential to improve the management of fecal incontinence, and offers patients a less-invasive alternative to traditional surgical approaches.

Sphinkeeper®植入手术技术。
大便失禁是一种令人痛苦的疾病,其特征是不自主地失去固体和液体粪便和气体。它影响了很大一部分普通人群,据报道患病率在1%至20%之间。尽管大便失禁对生活质量有很大影响,但其治疗选择仍然有限。目前大便失禁的治疗方式包括保守的方法,如饮食调整、盆底锻炼和药物治疗。在更严重的病例中,可以考虑手术干预,包括括约肌成形术或骶神经刺激。最近,THD实验室(意大利THD S.p.A.Correggio(RE))推出了Gatekeeper®,这是一种新型设备,可支持将多达四个固体假体植入乳头间沟。早期数据很有希望,成功率超过50%,只有少数围手术期并发症。随后,Gatekeeper®通过增加假体的长度和数量(最多10个)进行了修改,并更名为Sphinkeeper®(THD)。利用该装置,在距肛门2-3cm的距离处形成9至10个2mm的小切口。使用输送系统进入括约肌间隙,并通过肛门内超声检查定位。对围绕整个圆周放置的所有10个假体重复该过程。Sphinkeeper®具有改善大便失禁管理的潜力,并为患者提供了一种侵入性较小的传统手术方法替代方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.00
自引率
0.00%
发文量
141
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信