Agreement Between Epigastric Auscultation and pH Measurement in the Confirmation of Nasoenteral Tube Placement.

Pub Date : 2023-10-01 DOI:10.5152/FNJN.2023.22240
Joana Márcia Martins Duarte, Ariane Ranzani Rigotti, Mayara Carvalho Godinho Rigobello, Rosana Aparecida Pereira, Fernanda Raphael Escobar Gimenes
{"title":"Agreement Between Epigastric Auscultation and pH Measurement in the Confirmation of Nasoenteral Tube Placement.","authors":"Joana Márcia Martins Duarte, Ariane Ranzani Rigotti, Mayara Carvalho Godinho Rigobello, Rosana Aparecida Pereira, Fernanda Raphael Escobar Gimenes","doi":"10.5152/FNJN.2023.22240","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>This study aimed to evaluate the agreement between epigastric auscultation and pH measurement in the confirmation of nasoenteral tube placement.</p><p><strong>Method: </strong>A cross-sectional study carried out in a medium-sized private hospital in the interior of the state of São Paulo. Forty-nine patients who were submitted to ninety insertion procedures and confirmation of tube placement. aimed at evaluating the agreement of clinical methods used by nurses to confirm the positioning of a nasoenteral tube inserted blindly at the bedside, by measuring the parameters of sensitivity, specificity, positive predictive value, and negative predictive value.</p><p><strong>Results: </strong>The epigastric auscultation was the method that presented the highest sensitivity (100.0%), but lower specificity (2.0%). The measurement of the pH presented lower sensitivity (63.0%) than the auscultation, however, higher specificity (58%). Moreover, the positive predictive value of the pH measurement was 55% and the negative predictive value was 66%. There was no agreement between the epigastric auscultation and the pH measurement with the radiography.</p><p><strong>Conclusion: </strong>The pH measurement did not allow for distinguishing between gastric and enteric positioning, due to the similarity of the esophageal and pulmonary pH with the pH of the intestine. Furthermore, external factors such as the use of medication and reduced fasting time may interfere with the pH value.</p>","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10724715/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5152/FNJN.2023.22240","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: This study aimed to evaluate the agreement between epigastric auscultation and pH measurement in the confirmation of nasoenteral tube placement.

Method: A cross-sectional study carried out in a medium-sized private hospital in the interior of the state of São Paulo. Forty-nine patients who were submitted to ninety insertion procedures and confirmation of tube placement. aimed at evaluating the agreement of clinical methods used by nurses to confirm the positioning of a nasoenteral tube inserted blindly at the bedside, by measuring the parameters of sensitivity, specificity, positive predictive value, and negative predictive value.

Results: The epigastric auscultation was the method that presented the highest sensitivity (100.0%), but lower specificity (2.0%). The measurement of the pH presented lower sensitivity (63.0%) than the auscultation, however, higher specificity (58%). Moreover, the positive predictive value of the pH measurement was 55% and the negative predictive value was 66%. There was no agreement between the epigastric auscultation and the pH measurement with the radiography.

Conclusion: The pH measurement did not allow for distinguishing between gastric and enteric positioning, due to the similarity of the esophageal and pulmonary pH with the pH of the intestine. Furthermore, external factors such as the use of medication and reduced fasting time may interfere with the pH value.

分享
查看原文
胃上听诊和pH测量在鼻侧管放置确认中的一致性。
目的:本研究旨在评估上腹部听诊和pH测量在鼻肠管放置确认中的一致性。方法:在圣保罗州内陆的一家中型私立医院进行的横断面研究。49名患者接受了90次插入手术和导管放置确认。目的通过测量敏感性、特异性、阳性预测值和阴性预测值等参数,评价护士在床边盲插鼻肠管定位的临床方法的一致性。结果:上腹部听诊的灵敏度最高(100.0%),但特异度较低(2.0%);pH值测定的灵敏度较听诊低(63.0%),但特异性较高(58%)。此外,pH测量的阳性预测值为55%,阴性预测值为66%。上腹部听诊和用射线照相法测量pH值之间没有一致性。结论:由于食道和肺部的pH值与肠道的pH值相似,pH值测量无法区分胃和肠道的定位。此外,药物使用和禁食时间缩短等外部因素可能会干扰pH值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信