Importance of Capnography Monitoring in Critical Ill Patients.

Korean Journal of Critical Care Medicine Pub Date : 2017-02-01 Epub Date: 2017-02-28 DOI:10.4266/kjccm.2017.00101
Young-Kown Ko
{"title":"Importance of Capnography Monitoring in Critical Ill Patients.","authors":"Young-Kown Ko","doi":"10.4266/kjccm.2017.00101","DOIUrl":null,"url":null,"abstract":"Endotracheal intubation (EI) is the most commonly performed in the intensive care unit but has the potential to lead to critical complications [1]. Hence, the use of fluid loading, preoxygenation with noninvasive positive pressure ventilation, rapid sequence induction or capnography monitoring is recommended to make EI safer [2]. In this topic of The Korean Journal of Critical Care Medicine, Yoon et al. [3] reported a case “Endotracheal Tube Completely Severed by a Patient Bite and Lodged in the Right Main Bronchus.” In that case, the authors had difficulty inserting a suction catheter into the endotracheal tube (ETT) and after 30 minutes, they observed ETT damage caused by increased peak airway pressure, lower tidal volumes and reduced oxygen saturation. If the patient had been monitored using a capnography, such problems could have been detected sooner. According to a human cadaveric study, capnography is highly accurate in detecting a correct ETT placement showing 100% sensitivity and 100% specificity with the ability to provide highly reliable readings in low-perfusion states (cardiac arrest). Capnographic monitoring is therefore recommended as a gold standard for patients undergoing endotracheal intubation [4]. Capnography provides critical physiologic data regarding ventilation and perfusion matching in the lung, heart and metabolic rate [5]. In addition, it provides valuable patient safety information that can be used for a variety of clinical decisions, including the prediction of acute respiratory distress syndrome gradient [6], determination of outcome after cardiopulmonary resuscitation [7] and decision about esophageal intubation, unexpected extubation, disconnection of breathing circuit, the mechanical state of the lung. Therefore, the capacity of capnography can be aggressively used for monitoring critically ill patients.","PeriodicalId":31220,"journal":{"name":"Korean Journal of Critical Care Medicine","volume":"32 1","pages":"79-80"},"PeriodicalIF":0.0000,"publicationDate":"2017-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/0e/d9/kjccm-2017-00101.PMC6786740.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Korean Journal of Critical Care Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4266/kjccm.2017.00101","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2017/2/28 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Endotracheal intubation (EI) is the most commonly performed in the intensive care unit but has the potential to lead to critical complications [1]. Hence, the use of fluid loading, preoxygenation with noninvasive positive pressure ventilation, rapid sequence induction or capnography monitoring is recommended to make EI safer [2]. In this topic of The Korean Journal of Critical Care Medicine, Yoon et al. [3] reported a case “Endotracheal Tube Completely Severed by a Patient Bite and Lodged in the Right Main Bronchus.” In that case, the authors had difficulty inserting a suction catheter into the endotracheal tube (ETT) and after 30 minutes, they observed ETT damage caused by increased peak airway pressure, lower tidal volumes and reduced oxygen saturation. If the patient had been monitored using a capnography, such problems could have been detected sooner. According to a human cadaveric study, capnography is highly accurate in detecting a correct ETT placement showing 100% sensitivity and 100% specificity with the ability to provide highly reliable readings in low-perfusion states (cardiac arrest). Capnographic monitoring is therefore recommended as a gold standard for patients undergoing endotracheal intubation [4]. Capnography provides critical physiologic data regarding ventilation and perfusion matching in the lung, heart and metabolic rate [5]. In addition, it provides valuable patient safety information that can be used for a variety of clinical decisions, including the prediction of acute respiratory distress syndrome gradient [6], determination of outcome after cardiopulmonary resuscitation [7] and decision about esophageal intubation, unexpected extubation, disconnection of breathing circuit, the mechanical state of the lung. Therefore, the capacity of capnography can be aggressively used for monitoring critically ill patients.
脑电图监测在危重病人中的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
15 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信