Ping Yang, Yue Zhong, Chao Zhang, Yaping Zhang, Xu Fan, Hong Shi
{"title":"Contrast Agent Reflux in Transvaginal 4-D Hysterosalpingo-Contrast Sonography: Influencing Factors and Coping Strategies.","authors":"Ping Yang, Yue Zhong, Chao Zhang, Yaping Zhang, Xu Fan, Hong Shi","doi":"10.1097/RUQ.0000000000000661","DOIUrl":null,"url":null,"abstract":"<p><strong>Abstract: </strong>Transvaginal 4-D hysterosalpingo-contrast sonography (TV 4-D HyCoSy) plays an important role in the detection and diagnosis of clinical female infertility. The purposes of this study were to analyze the influencing factors of TV 4murD HyCoSy complicated with contrast agent reflux and to provide evidence for clinical diagnosis and treatment. Female patients diagnosed as infertility by transvaginal hysterosalpingography from January 2021 to December 2022 were included. The characteristics of patients with and without contrast agent reflux were evaluated. Pearson correlation and logistic regression were conducted to analyze the related factors affecting the occurrence of contrast reflux. A total of 416 patients undergoing TV 4-D HyCoSy were included, and the incidence of contrast agent reflux in patients undergoing TV 4-D HyCoSy was 38.94%. Pearson correlation analysis results indicated that history of uterine cavity operation ( r = 0.556), adenomyosis of uterus ( r = 0.584), examination on less than 5 days after menstruation ( r = 0.602), endometrial thickness ( r = 0.566), and endometrial polyps ( r = 0.575) are all correlated with contrast agent reflux in patients undergoing 4-D HyCoSy (all P < 0.05). Logistic regression analysis showed that history of uterine cavity operation (odds ratio [OR], 1.109; 95% confidence interval [CI], 1.012-1.872), adenomyosis of uterus (OR, 2.026; 95% CI, 1.864-2.425), examination on less than 5 days after menstruation (OR, 2.465; 95% CI, 2.118-2.851), endometrial thickness less than 6 mm (OR, 2.866; 95% CI, 2.095-2.957), and endometrial polyps (OR, 1.587; 95% CI, 1.137-1.744) were the influencing factors of contrast agent reflux in patients undergoing (all P < 0.05). The incidence of contrast agent reflux in TV 4-D HyCoSy is high, and there are many influencing factors. Clinical medical workers should take early measures based on these influencing factors to reduce the contrast agent reflux.</p>","PeriodicalId":49116,"journal":{"name":"Ultrasound Quarterly","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound Quarterly","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RUQ.0000000000000661","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Abstract: Transvaginal 4-D hysterosalpingo-contrast sonography (TV 4-D HyCoSy) plays an important role in the detection and diagnosis of clinical female infertility. The purposes of this study were to analyze the influencing factors of TV 4murD HyCoSy complicated with contrast agent reflux and to provide evidence for clinical diagnosis and treatment. Female patients diagnosed as infertility by transvaginal hysterosalpingography from January 2021 to December 2022 were included. The characteristics of patients with and without contrast agent reflux were evaluated. Pearson correlation and logistic regression were conducted to analyze the related factors affecting the occurrence of contrast reflux. A total of 416 patients undergoing TV 4-D HyCoSy were included, and the incidence of contrast agent reflux in patients undergoing TV 4-D HyCoSy was 38.94%. Pearson correlation analysis results indicated that history of uterine cavity operation ( r = 0.556), adenomyosis of uterus ( r = 0.584), examination on less than 5 days after menstruation ( r = 0.602), endometrial thickness ( r = 0.566), and endometrial polyps ( r = 0.575) are all correlated with contrast agent reflux in patients undergoing 4-D HyCoSy (all P < 0.05). Logistic regression analysis showed that history of uterine cavity operation (odds ratio [OR], 1.109; 95% confidence interval [CI], 1.012-1.872), adenomyosis of uterus (OR, 2.026; 95% CI, 1.864-2.425), examination on less than 5 days after menstruation (OR, 2.465; 95% CI, 2.118-2.851), endometrial thickness less than 6 mm (OR, 2.866; 95% CI, 2.095-2.957), and endometrial polyps (OR, 1.587; 95% CI, 1.137-1.744) were the influencing factors of contrast agent reflux in patients undergoing (all P < 0.05). The incidence of contrast agent reflux in TV 4-D HyCoSy is high, and there are many influencing factors. Clinical medical workers should take early measures based on these influencing factors to reduce the contrast agent reflux.
期刊介绍:
Ultrasound Quarterly provides coverage of the newest, most sophisticated ultrasound techniques as well as in-depth analysis of important developments in this dynamic field. The journal publishes reviews of a wide variety of topics including trans-vaginal ultrasonography, detection of fetal anomalies, color Doppler flow imaging, pediatric ultrasonography, and breast sonography.
Official Journal of the Society of Radiologists in Ultrasound