{"title":"ProGlide entrapment of the occlusive balloon during repair of an iatrogenic subclavian artery injury.","authors":"Benjamin Jr Kemp, Daniel J Kearns, Raman Uberoi","doi":"10.1259/bjrcr.20230015","DOIUrl":null,"url":null,"abstract":"<p><p>The insertion of any central venous catheter (CVC) is associated with a risk of damage to neurovascular structures, pneumothorax, cardiac arrhythmias, and infection<sup>1</sup>. Unintentional arterial puncture remains rare, occurring in 6.3-9.4% of attempted internal jugular vein (IJV) catheterisation and 3.1-4.9% of attempted subclavian vein catheterisation<sup>2</sup>. We present a previously undocumented complication encountered while utilising the Perclose ProGlide device in the case of a 59-year-old male who underwent right subclavian artery closure following the accidental insertion of a 14Fr Vascath into the right subclavian artery. This was performed using two ProGlide devices and one Angio-Seal device. Following deployment of the ProGlide devices, an uninflated balloon passed into the subclavian artery as a precaution, but not used, was removed. One of the ProGlide devices became dislodged having been deployed into the balloon, threatening haemostasis.</p>","PeriodicalId":45216,"journal":{"name":"BJR Case Reports","volume":"9 5","pages":"20230015"},"PeriodicalIF":0.5000,"publicationDate":"2023-09-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10513006/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BJR Case Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1259/bjrcr.20230015","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/10/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
The insertion of any central venous catheter (CVC) is associated with a risk of damage to neurovascular structures, pneumothorax, cardiac arrhythmias, and infection1. Unintentional arterial puncture remains rare, occurring in 6.3-9.4% of attempted internal jugular vein (IJV) catheterisation and 3.1-4.9% of attempted subclavian vein catheterisation2. We present a previously undocumented complication encountered while utilising the Perclose ProGlide device in the case of a 59-year-old male who underwent right subclavian artery closure following the accidental insertion of a 14Fr Vascath into the right subclavian artery. This was performed using two ProGlide devices and one Angio-Seal device. Following deployment of the ProGlide devices, an uninflated balloon passed into the subclavian artery as a precaution, but not used, was removed. One of the ProGlide devices became dislodged having been deployed into the balloon, threatening haemostasis.