Osmo Anttalainen, Elie Lattouf, Paula Vanninen, Hanna Hakulinen, Tapio Kotiaho, Gary Eiceman
{"title":"Computational analysis of an electrostatic separator design for removal of volatile organic compounds from indoor air.","authors":"Osmo Anttalainen, Elie Lattouf, Paula Vanninen, Hanna Hakulinen, Tapio Kotiaho, Gary Eiceman","doi":"10.1080/10962247.2023.2265329","DOIUrl":null,"url":null,"abstract":"<p><p>Concentrations of volatile organic compounds (VOCs) in air can be reduced in electrostatic separators where VOCs are ionized using ion-molecule reactions, extracted using electric fields, and eliminated in a waste flow. Embodiments for such separator technology have been explored in only a few studies, despite the possible advantage of purification without adsorbent filters. In one design, based on ionization of VOCs in positive polarity with hydrated protons as reactant ions, efficiencies for removal were measured as 30-40% . The results were fitted to a one-dimensional convective diffusion model requiring an unexpectedly high production rate of reactant ions to match both the model and data. A realistic rate of reactant ion production was used in finite element method simulations (COMSOL) and demonstrated that low removal efficiency could be attributed to non-uniform patterns of sample flow and to incomplete mixing of VOCs with reactant ions. In analysis of complex systems, such as this model, even limited computational modeling can outperform a pure analytical approach and bring insights into limiting factors or system bottlenecks.<i>Implications:</i> In this work, we applied modern computational methods to understand the performance of an air purifier based on electrostatics and ionized volatile organic compounds (VOCs). These were described in the publication early 2000s. The model presented was one-dimensional and did not account for the effects of flow. In our multiphysics finite element models, the efficiency and operation of the filter is better explained by the patterns of flow and flow influences on ion distributions in electric fields. In general, this work helps using and applying computational modelling to understand and improve the performance bottlenecks in air purification system designs.</p>","PeriodicalId":49171,"journal":{"name":"Journal of the Air & Waste Management Association","volume":" ","pages":"877-889"},"PeriodicalIF":2.1000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Air & Waste Management Association","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1080/10962247.2023.2265329","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/11/27 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, ENVIRONMENTAL","Score":null,"Total":0}
引用次数: 0
Abstract
Concentrations of volatile organic compounds (VOCs) in air can be reduced in electrostatic separators where VOCs are ionized using ion-molecule reactions, extracted using electric fields, and eliminated in a waste flow. Embodiments for such separator technology have been explored in only a few studies, despite the possible advantage of purification without adsorbent filters. In one design, based on ionization of VOCs in positive polarity with hydrated protons as reactant ions, efficiencies for removal were measured as 30-40% . The results were fitted to a one-dimensional convective diffusion model requiring an unexpectedly high production rate of reactant ions to match both the model and data. A realistic rate of reactant ion production was used in finite element method simulations (COMSOL) and demonstrated that low removal efficiency could be attributed to non-uniform patterns of sample flow and to incomplete mixing of VOCs with reactant ions. In analysis of complex systems, such as this model, even limited computational modeling can outperform a pure analytical approach and bring insights into limiting factors or system bottlenecks.Implications: In this work, we applied modern computational methods to understand the performance of an air purifier based on electrostatics and ionized volatile organic compounds (VOCs). These were described in the publication early 2000s. The model presented was one-dimensional and did not account for the effects of flow. In our multiphysics finite element models, the efficiency and operation of the filter is better explained by the patterns of flow and flow influences on ion distributions in electric fields. In general, this work helps using and applying computational modelling to understand and improve the performance bottlenecks in air purification system designs.
期刊介绍:
The Journal of the Air & Waste Management Association (J&AWMA) is one of the oldest continuously published, peer-reviewed, technical environmental journals in the world. First published in 1951 under the name Air Repair, J&AWMA is intended to serve those occupationally involved in air pollution control and waste management through the publication of timely and reliable information.