Comparability and Stability of Serum Creatinine Concentration in Capillary and Venous Blood.

IF 2.7 4区 医学 Q2 MEDICAL LABORATORY TECHNOLOGY
British Journal of Biomedical Science Pub Date : 2023-09-11 eCollection Date: 2023-01-01 DOI:10.3389/bjbs.2023.11402
Timothy Woolley, Emma Rutter, Macarena Staudenmaier
{"title":"Comparability and Stability of Serum Creatinine Concentration in Capillary and Venous Blood.","authors":"Timothy Woolley,&nbsp;Emma Rutter,&nbsp;Macarena Staudenmaier","doi":"10.3389/bjbs.2023.11402","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> The use of self-collected capillary blood has several advantages over phlebotomy, as such finger-prick testing is rapidly becoming accepted as a routine sample type for adults. However, there is limited evidence that venous and capillary serum is comparable for many analytes. This study aimed to determine whether capillary samples could offer an alternative sampling method to venous samples for the assessment of serum creatinine using the enzymatic method and if this analyte was stable in unspun capillary blood for 3 days. <b>Methods:</b> Matched capillary and venous blood samples were collected from 48 patients for the determination of serum creatinine, one set being processed on day zero, the other set being stored at ambient temperature and then processed on day three. Self-collected capillary blood was compared with phlebotomist-collected venous samples. <b>Results:</b> Serum creatinine concentrations from venous and capillary blood samples taken on day zero were compared to concentrations in capillary blood from day three. Data produced showed serum creatinine concentrations from capillary and venous serum to be comparable. <b>Conclusion:</b> It is believed that this is the first published study to determine if self-collected capillary blood sampling is an acceptable alternative to venous sampling for the measurement of serum creatinine concentration; our data indicates that there is no significant difference in results from unspun venous and capillary blood stored at room temperature for at least 3 days compared to venous blood tested on the same day of collection.</p>","PeriodicalId":9236,"journal":{"name":"British Journal of Biomedical Science","volume":"80 ","pages":"11402"},"PeriodicalIF":2.7000,"publicationDate":"2023-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10519179/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"British Journal of Biomedical Science","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3389/bjbs.2023.11402","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The use of self-collected capillary blood has several advantages over phlebotomy, as such finger-prick testing is rapidly becoming accepted as a routine sample type for adults. However, there is limited evidence that venous and capillary serum is comparable for many analytes. This study aimed to determine whether capillary samples could offer an alternative sampling method to venous samples for the assessment of serum creatinine using the enzymatic method and if this analyte was stable in unspun capillary blood for 3 days. Methods: Matched capillary and venous blood samples were collected from 48 patients for the determination of serum creatinine, one set being processed on day zero, the other set being stored at ambient temperature and then processed on day three. Self-collected capillary blood was compared with phlebotomist-collected venous samples. Results: Serum creatinine concentrations from venous and capillary blood samples taken on day zero were compared to concentrations in capillary blood from day three. Data produced showed serum creatinine concentrations from capillary and venous serum to be comparable. Conclusion: It is believed that this is the first published study to determine if self-collected capillary blood sampling is an acceptable alternative to venous sampling for the measurement of serum creatinine concentration; our data indicates that there is no significant difference in results from unspun venous and capillary blood stored at room temperature for at least 3 days compared to venous blood tested on the same day of collection.

Abstract Image

毛细管血和静脉血中血清肌酸浓度的可比性和稳定性。
背景:与静脉切开术相比,使用自行采集的毛细管血有几个优点,因为手指点刺测试正迅速被接受为成年人的常规样本类型。然而,有限的证据表明静脉和毛细管血清对许多分析物具有可比性。本研究旨在确定毛细管样品是否可以提供一种替代静脉样品的采样方法,用于使用酶法评估血清肌酸酐,以及该分析物在未稀释的毛细管血中是否稳定3天。方法:从48名患者中采集匹配的毛细管和静脉血样,用于测定血清肌酐,一组在第0天处理,另一组在环境温度下储存,然后在第3天处理。将自行采集的毛细管血与抽血医生采集的静脉样本进行比较。结果:将第0天采集的静脉和毛细管血液样本中的血清肌酸酐浓度与第3天采集的毛细管血液中的浓度进行比较。所产生的数据显示,来自毛细管和静脉血清的血清肌酸酐浓度具有可比性。结论:据信,这是第一项已发表的研究,以确定自采毛细管血取样是否是静脉取样测量血清肌酸酐浓度的可接受替代方案;我们的数据表明,与采集当天测试的静脉血相比,在室温下储存至少3天的未穿刺静脉血和毛细管血的结果没有显著差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
British Journal of Biomedical Science
British Journal of Biomedical Science 医学-医学实验技术
CiteScore
4.40
自引率
15.80%
发文量
29
审稿时长
>12 weeks
期刊介绍: The British Journal of Biomedical Science is committed to publishing high quality original research that represents a clear advance in the practice of biomedical science, and reviews that summarise recent advances in the field of biomedical science. The overall aim of the Journal is to provide a platform for the dissemination of new and innovative information on the diagnosis and management of disease that is valuable to the practicing laboratory scientist.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信