Patient-ventilator interaction during noninvasive positive pressure ventilation.

Stefano Nava, Piero Ceriana
{"title":"Patient-ventilator interaction during noninvasive positive pressure ventilation.","authors":"Stefano Nava,&nbsp;Piero Ceriana","doi":"10.1016/j.rcc.2005.02.003","DOIUrl":null,"url":null,"abstract":"<p><p>The interaction between the patient and the ventilator is complex,especially in a \"semi-open\" system as for noninvasive ventilation(NIV). Air leaks around the mask are likely to occur, and they affect patient-ventilator synchrony. Several variables may be responsible for the mismatch between the start of the neural output and that of ventilatory aid during NIV. The most common mode of ventilation is pressure support ventilation (PSV), which may result in a number of inspiratory efforts not being followed by ventilator aid. New modes of ventilation, such as proportional assist ventilation, maybe useful in improving patient tolerance to ventilation without affecting clinical outcome. The ventilatory settings are important during PSV to determine the synchrony. The inspiratory trigger function may be influenced by the amount of leaks, whereas a better synchrony may be achieved if the termination of the inspiratory phase is time cycled instead of flow cycled. A high pressurization rate results in poor compliance. Care should be paid in the choice of the interfaces because leaks in the system are associated with a substantial breath-to-breath inspiratory variation independent from the patient effort. Last, NIV should be delivered with turbine- or piston-based ventilators that are able to compensate for air leaks. With respect to the problem of sedation, we point out the importance of optimizing the environmental conditions, avoiding excessive light and noise, assuring patient comfort, and providing reassurance. When sedation is needed, we suggest the use of low doses of analgesics and neuroleptic agents in selected cases.</p>","PeriodicalId":79530,"journal":{"name":"Respiratory care clinics of North America","volume":"11 2","pages":"281-93"},"PeriodicalIF":0.0000,"publicationDate":"2005-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.rcc.2005.02.003","citationCount":"21","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Respiratory care clinics of North America","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1016/j.rcc.2005.02.003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 21

Abstract

The interaction between the patient and the ventilator is complex,especially in a "semi-open" system as for noninvasive ventilation(NIV). Air leaks around the mask are likely to occur, and they affect patient-ventilator synchrony. Several variables may be responsible for the mismatch between the start of the neural output and that of ventilatory aid during NIV. The most common mode of ventilation is pressure support ventilation (PSV), which may result in a number of inspiratory efforts not being followed by ventilator aid. New modes of ventilation, such as proportional assist ventilation, maybe useful in improving patient tolerance to ventilation without affecting clinical outcome. The ventilatory settings are important during PSV to determine the synchrony. The inspiratory trigger function may be influenced by the amount of leaks, whereas a better synchrony may be achieved if the termination of the inspiratory phase is time cycled instead of flow cycled. A high pressurization rate results in poor compliance. Care should be paid in the choice of the interfaces because leaks in the system are associated with a substantial breath-to-breath inspiratory variation independent from the patient effort. Last, NIV should be delivered with turbine- or piston-based ventilators that are able to compensate for air leaks. With respect to the problem of sedation, we point out the importance of optimizing the environmental conditions, avoiding excessive light and noise, assuring patient comfort, and providing reassurance. When sedation is needed, we suggest the use of low doses of analgesics and neuroleptic agents in selected cases.

无创正压通气期间患者与呼吸机的相互作用。
患者与呼吸机之间的相互作用是复杂的,特别是在无创通气(NIV)的“半开放式”系统中。口罩周围可能会发生漏气,并影响患者与呼吸机的同步。几个变量可能负责在NIV期间神经输出开始和通气辅助之间的不匹配。最常见的通气模式是压力支持通气(PSV),这可能导致一些吸气努力没有跟随呼吸机辅助。新的通气模式,如比例辅助通气,可能有助于提高患者对通气的耐受性,而不影响临床结果。在PSV期间,通气设置对于确定同步性很重要。吸气触发功能可能受到泄漏量的影响,而如果吸气相的终止是时间循环的而不是流动循环的,则可以实现更好的同步性。高加压率导致顺应性差。在选择接口时应注意,因为系统中的泄漏与大量的呼吸到呼吸的变化有关,与患者的努力无关。最后,NIV应与能够补偿空气泄漏的涡轮或活塞式通风机一起交付。关于镇静问题,我们指出优化环境条件,避免过度的光线和噪音,确保患者舒适,并提供安心的重要性。当需要镇静时,我们建议在选定的病例中使用低剂量的镇痛药和抗精神病药物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信