Cinchocaine hydrochloride determination by atomic absorption spectrometry and spectrophotometry

Nour T. Abdel-Ghani, Ahmed F.A. Youssef, Mohamed A. Awady
{"title":"Cinchocaine hydrochloride determination by atomic absorption spectrometry and spectrophotometry","authors":"Nour T. Abdel-Ghani,&nbsp;Ahmed F.A. Youssef,&nbsp;Mohamed A. Awady","doi":"10.1016/j.farmac.2005.03.001","DOIUrl":null,"url":null,"abstract":"<div><p>Two sensitive spectrophotometric and atomic absorption spectrometric procedures have been developed for determination of cinchocaine hydrochloride (Cin.Cl) in pure form and in pharmaceutical formulation. The spectrophotometric method was based on formation of an insoluble colored ion-associate between the cited drug and tetrathiocyanatocobaltate (CoTC) or hexathiocyanatochromate (CrTC) which dissolved and extracted in an organic solvent. The optimal experimental conditions for quantitative extraction such as pH, concentration of the reagents and solvent were studied. Toluene and iso-butyl alcohol proved to be the most suitable solvents for quantitative extraction of Cin-CoTC and Cin-CrTC ion-associates with maximum absorbance at 620 and 555 nm, respectively. The optimum concentration ranges, molar absorptivities, Ringbom ranges and Sandell sensitivities were also evaluated.</p><p>The atomic absorption spectrometric method is based on measuring of the excess cobalt or chromium in the aqueous solution, after precipitation of the drug, at 240.7 and 357.9 nm, respectively. Linear application ranges, characteristic masses and detection limits were 57.99–361.9, 50.40 and 4.22 μg ml<sup>–1</sup> of Cin.Cl, in case of CoTC, while 37.99–379.9, 18.94 and 0.81 μg ml<sup>–1</sup> in case of CrTC.</p></div>","PeriodicalId":77128,"journal":{"name":"Farmaco (Societa chimica italiana : 1989)","volume":"60 5","pages":"Pages 419-424"},"PeriodicalIF":0.0000,"publicationDate":"2005-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.farmac.2005.03.001","citationCount":"17","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Farmaco (Societa chimica italiana : 1989)","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0014827X05000625","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

Abstract

Two sensitive spectrophotometric and atomic absorption spectrometric procedures have been developed for determination of cinchocaine hydrochloride (Cin.Cl) in pure form and in pharmaceutical formulation. The spectrophotometric method was based on formation of an insoluble colored ion-associate between the cited drug and tetrathiocyanatocobaltate (CoTC) or hexathiocyanatochromate (CrTC) which dissolved and extracted in an organic solvent. The optimal experimental conditions for quantitative extraction such as pH, concentration of the reagents and solvent were studied. Toluene and iso-butyl alcohol proved to be the most suitable solvents for quantitative extraction of Cin-CoTC and Cin-CrTC ion-associates with maximum absorbance at 620 and 555 nm, respectively. The optimum concentration ranges, molar absorptivities, Ringbom ranges and Sandell sensitivities were also evaluated.

The atomic absorption spectrometric method is based on measuring of the excess cobalt or chromium in the aqueous solution, after precipitation of the drug, at 240.7 and 357.9 nm, respectively. Linear application ranges, characteristic masses and detection limits were 57.99–361.9, 50.40 and 4.22 μg ml–1 of Cin.Cl, in case of CoTC, while 37.99–379.9, 18.94 and 0.81 μg ml–1 in case of CrTC.

原子吸收光谱法和分光光度法测定盐酸钦chocaine
建立了两种灵敏的分光光度法和原子吸收光谱法测定盐酸钦chocaine (Cin.Cl)的方法。分光光度法是基于被引药物与四硫氰酸盐(CoTC)或六硫氰酸盐(CrTC)之间形成不溶性有色离子缔合物,该离子缔合物溶解并在有机溶剂中提取。研究了定量提取的最佳实验条件,如pH、试剂浓度和溶剂浓度。甲苯和异丁醇分别在620 nm和555nm处具有最大吸光度,是定量提取Cin-CoTC和Cin-CrTC离子缔合物的最佳溶剂。并对最佳浓度范围、摩尔吸光度、林邦范围和桑德尔灵敏度进行了评价。原子吸收光谱法是在药物沉淀后,分别在240.7 nm和357.9 nm处测量水溶液中过量的钴或铬。Cin的线性适用范围、特征质量和检出限分别为57.99 ~ 361.9、50.40和4.22 μg ml-1。CoTC为37.99 ~ 379.9,CrTC为18.94、0.81 μ ml-1。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信