Electromagnetic interference in cardiac rhythm management devices.

Mark W Sweesy, James L Holland, Kerry W Smith
{"title":"Electromagnetic interference in cardiac rhythm management devices.","authors":"Mark W Sweesy,&nbsp;James L Holland,&nbsp;Kerry W Smith","doi":"10.1097/00044067-200407000-00007","DOIUrl":null,"url":null,"abstract":"<p><p>Clinicians caring for cardiac device patients with implanted pacemakers or cardioverter defibrillators (ICDs) are frequently asked questions by their patients concerning electromagnetic interference (EMI) sources and the devices. EMI may be radiated or conducted and may be present in many different forms including (but not limited to) radiofrequency waves, microwaves, ionizing radiation, acoustic radiation, static and pulsed magnetic fields, and electric currents. Manufacturers have done an exemplary job of interference protection with device features such as titanium casing, signal filtering, interference rejection circuits, feedthrough capacitors, noise reversion function, and programmable parameters. Nevertheless, EMI remains a real concern and a potential danger. Many factors influence EMI including those which the patient can regulate (eg, distance from and duration of exposure) and some the patient cannot control (eg, intensity of the EMI field, signal frequency). Potential device responses are many and range from simple temporary oversensing to permanent device damage Several of the more common EMI-generating devices and their likely effects on cardiac devices are considered in the medical, home, and daily living and work environments.</p>","PeriodicalId":79311,"journal":{"name":"AACN clinical issues","volume":"15 3","pages":"391-403"},"PeriodicalIF":0.0000,"publicationDate":"2004-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1097/00044067-200407000-00007","citationCount":"46","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"AACN clinical issues","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/00044067-200407000-00007","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 46

Abstract

Clinicians caring for cardiac device patients with implanted pacemakers or cardioverter defibrillators (ICDs) are frequently asked questions by their patients concerning electromagnetic interference (EMI) sources and the devices. EMI may be radiated or conducted and may be present in many different forms including (but not limited to) radiofrequency waves, microwaves, ionizing radiation, acoustic radiation, static and pulsed magnetic fields, and electric currents. Manufacturers have done an exemplary job of interference protection with device features such as titanium casing, signal filtering, interference rejection circuits, feedthrough capacitors, noise reversion function, and programmable parameters. Nevertheless, EMI remains a real concern and a potential danger. Many factors influence EMI including those which the patient can regulate (eg, distance from and duration of exposure) and some the patient cannot control (eg, intensity of the EMI field, signal frequency). Potential device responses are many and range from simple temporary oversensing to permanent device damage Several of the more common EMI-generating devices and their likely effects on cardiac devices are considered in the medical, home, and daily living and work environments.

心律管理装置中的电磁干扰。
临床医生照顾植入心脏起搏器或心脏转复除颤器(ICDs)的心脏设备患者经常被患者问及有关电磁干扰(EMI)来源和设备的问题。电磁干扰可以被辐射或传导,并可能以许多不同的形式存在,包括(但不限于)射频波、微波、电离辐射、声辐射、静态和脉冲磁场以及电流。制造商通过钛外壳、信号滤波、干扰抑制电路、馈通电容器、噪声恢复功能和可编程参数等设备功能,完成了干扰保护的示范工作。尽管如此,百代仍是一个真正的问题和潜在的危险。影响电磁干扰的因素很多,包括患者可以调节的因素(例如,接触的距离和持续时间)和一些患者无法控制的因素(例如,电磁干扰场的强度,信号频率)。潜在的设备反应有很多,范围从简单的暂时性过感到永久性设备损坏。在医疗、家庭和日常生活和工作环境中,考虑了几种更常见的产生emi的设备及其对心脏设备的可能影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信