Investigation of GC detectors performance and validation.

G H Pandya
{"title":"Investigation of GC detectors performance and validation.","authors":"G H Pandya","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Detectors in gas chromatographs are used in many different ways. The functions varies with the requirement of sensing the chemicals at trace levels to measuring quantitatively the relative amounts of compounds in ppb to sub ppb levels. The requirement of minimum detectable sensitivity for GC detectors and its actual estimation during the analysis helps in assessing the performance of detectors and a stable response of the GC system. The paper reports the study carried out with a GC system equipped with detectors like Flame Ionization Detector(FID) and Electron Capture Detector(ECD). Both packed and capillary column have been used for estimating the minimum detectability of detectors. The FID sensitivity obtained is 1.14 coulombs/g C. The FID could minimum detect 2.65 x 10(-12) gram carbon per sec and ECD could minimum detect pesticides (Lindane) less than 1 femtogram. Such a procedure is useful for all those engaged in analysis with GC or are in the process of procuring good reliable GC system.</p>","PeriodicalId":84892,"journal":{"name":"Indian journal of environmental health","volume":"45 2","pages":"139-42"},"PeriodicalIF":0.0000,"publicationDate":"2003-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian journal of environmental health","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Detectors in gas chromatographs are used in many different ways. The functions varies with the requirement of sensing the chemicals at trace levels to measuring quantitatively the relative amounts of compounds in ppb to sub ppb levels. The requirement of minimum detectable sensitivity for GC detectors and its actual estimation during the analysis helps in assessing the performance of detectors and a stable response of the GC system. The paper reports the study carried out with a GC system equipped with detectors like Flame Ionization Detector(FID) and Electron Capture Detector(ECD). Both packed and capillary column have been used for estimating the minimum detectability of detectors. The FID sensitivity obtained is 1.14 coulombs/g C. The FID could minimum detect 2.65 x 10(-12) gram carbon per sec and ECD could minimum detect pesticides (Lindane) less than 1 femtogram. Such a procedure is useful for all those engaged in analysis with GC or are in the process of procuring good reliable GC system.

GC检测器性能和验证的研究。
气相色谱仪中的检测器有许多不同的用途。其功能随检测微量化学物质到定量测量ppb至亚ppb水平化合物的相对量的要求而变化。分析过程中对气相色谱检测器最低检测灵敏度的要求及其实际估计有助于评估检测器的性能和气相色谱系统的稳定响应。本文报告了用配备火焰电离检测器(FID)和电子捕获检测器(ECD)等检测器的气相色谱系统进行的研究。填料柱和毛细管柱均可用于估计检测器的最小可检出性。得到的FID灵敏度为1.14库仑/g c, FID最小可检测2.65 × 10(-12)克碳/秒,ECD最小可检测农药(林丹)小于1飞图克。该程序对所有从事气相色谱分析或正在获得良好可靠的气相色谱系统的人员都是有用的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信