The Diagnostic Accuracy of Galectin-9 for Diagnosis of Endometriosis in Comparison with Laparoscopy.

Q2 Medicine
Sahar Jarollahi, Shahla Chaichian, Ali Jarollahi, Roya Hajmohammadi, Reza Mashayekhi, Fereshteh Shahmohammadi, Mohammad Eslamivaghar, Ziba Ghasemi
{"title":"The Diagnostic Accuracy of Galectin-9 for Diagnosis of Endometriosis in Comparison with Laparoscopy.","authors":"Sahar Jarollahi, Shahla Chaichian, Ali Jarollahi, Roya Hajmohammadi, Reza Mashayekhi, Fereshteh Shahmohammadi, Mohammad Eslamivaghar, Ziba Ghasemi","doi":"10.18502/jri.v23i4.10812","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Endometriosis is a common devastating gynecological disease with severe complications. Researches on noninvasive diagnostic tests with acceptable accuracy are still ongoing. The purpose of the present study was to evaluate the diagnostic value of serum Galectin-9 (Gal-9) level in comparison with laparoscopic results in endometriosis patients.</p><p><strong>Methods: </strong>Sixty-one patients, referred to Booali, Rasool-e-Akram, and Pars Hospitals affiliated to Islamic Azad University of Medical Sciences, were recruited. Patients laparoscopically diagnosed with endometriosis were assigned to the case (n=32) and who diagnosed with other diseases were assigned to the control group (n=29). In general, 56 patients (30 in case and 26 in control group) completed the study. The serum level of Galectin-9 was measured using ELISA method before laparoscopy and was compared between the groups. Next, categorical variables were compared using Chi square and quantitative variables using independent samples t- test or Mann-Whitney U test. The Gal-9 cut-off was calculated using the Youden's index and ROC curve; then, sensitivity, specificity, positive and negative predictive value, and positive and negative likelihood ratio of Gal-9 were reported. The p<0.05 were considered statistically significant.</p><p><strong>Results: </strong>Mean serum level of Galectin-9 was 669.3±416.50 <i>pg/ml</i> in the case group and 265.42±492.30 <i>pg/ml</i> in the control group (p=0.001). Considering a cut-off value of 138 <i>pg/ml</i>, Galectin-9 had a sensitivity of 100% and specificity of 88.46% for diagnosis of endometriosis (p<0.001).</p><p><strong>Conclusion: </strong>Galectin-9 measurement is helpful in diagnosis of endometriosis. Future studies are recommended for investigating the generalizability of these results.</p>","PeriodicalId":38826,"journal":{"name":"Journal of Reproduction and Infertility","volume":"23 4","pages":"271-278"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/e5/79/JRI-23-271.PMC9674464.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Reproduction and Infertility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18502/jri.v23i4.10812","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Endometriosis is a common devastating gynecological disease with severe complications. Researches on noninvasive diagnostic tests with acceptable accuracy are still ongoing. The purpose of the present study was to evaluate the diagnostic value of serum Galectin-9 (Gal-9) level in comparison with laparoscopic results in endometriosis patients.

Methods: Sixty-one patients, referred to Booali, Rasool-e-Akram, and Pars Hospitals affiliated to Islamic Azad University of Medical Sciences, were recruited. Patients laparoscopically diagnosed with endometriosis were assigned to the case (n=32) and who diagnosed with other diseases were assigned to the control group (n=29). In general, 56 patients (30 in case and 26 in control group) completed the study. The serum level of Galectin-9 was measured using ELISA method before laparoscopy and was compared between the groups. Next, categorical variables were compared using Chi square and quantitative variables using independent samples t- test or Mann-Whitney U test. The Gal-9 cut-off was calculated using the Youden's index and ROC curve; then, sensitivity, specificity, positive and negative predictive value, and positive and negative likelihood ratio of Gal-9 were reported. The p<0.05 were considered statistically significant.

Results: Mean serum level of Galectin-9 was 669.3±416.50 pg/ml in the case group and 265.42±492.30 pg/ml in the control group (p=0.001). Considering a cut-off value of 138 pg/ml, Galectin-9 had a sensitivity of 100% and specificity of 88.46% for diagnosis of endometriosis (p<0.001).

Conclusion: Galectin-9 measurement is helpful in diagnosis of endometriosis. Future studies are recommended for investigating the generalizability of these results.

Abstract Image

Abstract Image

与腹腔镜检查相比,Galectin-9 对子宫内膜异位症的诊断准确性。
背景:子宫内膜异位症是一种常见的破坏性妇科疾病,具有严重的并发症。有关准确性可接受的非侵入性诊断测试的研究仍在进行中。本研究的目的是评估血清 Galectin-9 (Gal-9) 水平与腹腔镜检查结果在子宫内膜异位症患者中的诊断价值:方法:研究人员招募了61名患者,分别转诊至伊斯兰阿扎德医科大学附属Booali医院、Rasool-e-Akram医院和Pars医院。经腹腔镜确诊为子宫内膜异位症的患者被分配到病例组(32 人),确诊为其他疾病的患者被分配到对照组(29 人)。总共有 56 名患者(病例组 30 人,对照组 26 人)完成了研究。在腹腔镜手术前,采用 ELISA 方法测量了血清中 Galectin-9 的水平,并在两组之间进行了比较。然后,使用卡方检验比较分类变量,使用独立样本 t 检验或 Mann-Whitney U 检验比较定量变量。利用尤登指数和 ROC 曲线计算 Gal-9 临界值,然后报告 Gal-9 的敏感性、特异性、阳性和阴性预测值以及阳性和阴性似然比。结果病例组 Galectin-9 的平均血清水平为 669.3±416.50 pg/ml,对照组为 265.42±492.30 pg/ml(P=0.001)。考虑到临界值为 138 pg/ml,Galectin-9 对子宫内膜异位症诊断的敏感性为 100%,特异性为 88.46%(p 结论:Galectin-9 测量有助于子宫内膜异位症的诊断:Galectin-9 测量有助于诊断子宫内膜异位症。建议今后对这些结果的推广性进行研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Reproduction and Infertility
Journal of Reproduction and Infertility Medicine-Reproductive Medicine
CiteScore
2.70
自引率
0.00%
发文量
44
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信