Total knee replacements using rotating hinge implants in polio patients: clinical and functional outcomes.

Q1 Medicine
MUSCULOSKELETAL SURGERY Pub Date : 2025-06-01 Epub Date: 2022-08-10 DOI:10.1007/s12306-022-00755-w
V Digennaro, M Manzetti, B D Bulzacki Bogucki, F Barile, A Panciera, G Viroli, R Ferri, D Cecchin, A Ruffilli, C Faldini
{"title":"Total knee replacements using rotating hinge implants in polio patients: clinical and functional outcomes.","authors":"V Digennaro, M Manzetti, B D Bulzacki Bogucki, F Barile, A Panciera, G Viroli, R Ferri, D Cecchin, A Ruffilli, C Faldini","doi":"10.1007/s12306-022-00755-w","DOIUrl":null,"url":null,"abstract":"<p><p>Little evidences are available in the literature concerning the outcomes of total knee replacement (TKR) in poliomyelitis patients with severe knee deformities or degeneration. Encouraging results have been reported concerning the use of constrained implants, i.e., rotating hinge knee prosthesis (RHK), compared to less constrained ones. The purpose of this paper is to report our experience with rotating hinge total knee replacement, using only RHK prosthesis, to determine functional results, complications, and survival of TKR in poliomyelitis patients. We performed a retrospective chart review of 14 patients with a history of knee osteoarthritis following poliomyelitis that underwent primary TKR, for a total of 15 surgical procedure (one bilateral case). Preoperative and postoperative clinical measurements have been conducted for all patients using the Knee Society Score (KSS). Hip-knee angle, recurvatum knee angle, and Insall-Salvati index were evaluated with full weight-bearing panoramic view X-ray preoperatively and postoperatively. The 2-year postoperative clinical KSS significantly improved from the preoperative scores. The average clinical KSS improved from 32,9 (range 3-48) preoperatively to 77,4 (range 60-88) postoperatively (P value < 0.005). The average functional KSS improved from 32,5 (range 10-60) preoperatively to 59,4 (range 30-95) postoperatively (P value < 0.005). TKR is a successful treatment in improving knee function and patient's quality of life. Using constrained implants, especially rotating hinge implants in polio patients with a quadriceps muscle weakness, could be a good alternative to maintain a physiological kinematics and reducing the revision rate due to knee instability.</p>","PeriodicalId":18875,"journal":{"name":"MUSCULOSKELETAL SURGERY","volume":" ","pages":"155-162"},"PeriodicalIF":0.0000,"publicationDate":"2025-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12122623/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"MUSCULOSKELETAL SURGERY","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s12306-022-00755-w","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/8/10 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Little evidences are available in the literature concerning the outcomes of total knee replacement (TKR) in poliomyelitis patients with severe knee deformities or degeneration. Encouraging results have been reported concerning the use of constrained implants, i.e., rotating hinge knee prosthesis (RHK), compared to less constrained ones. The purpose of this paper is to report our experience with rotating hinge total knee replacement, using only RHK prosthesis, to determine functional results, complications, and survival of TKR in poliomyelitis patients. We performed a retrospective chart review of 14 patients with a history of knee osteoarthritis following poliomyelitis that underwent primary TKR, for a total of 15 surgical procedure (one bilateral case). Preoperative and postoperative clinical measurements have been conducted for all patients using the Knee Society Score (KSS). Hip-knee angle, recurvatum knee angle, and Insall-Salvati index were evaluated with full weight-bearing panoramic view X-ray preoperatively and postoperatively. The 2-year postoperative clinical KSS significantly improved from the preoperative scores. The average clinical KSS improved from 32,9 (range 3-48) preoperatively to 77,4 (range 60-88) postoperatively (P value < 0.005). The average functional KSS improved from 32,5 (range 10-60) preoperatively to 59,4 (range 30-95) postoperatively (P value < 0.005). TKR is a successful treatment in improving knee function and patient's quality of life. Using constrained implants, especially rotating hinge implants in polio patients with a quadriceps muscle weakness, could be a good alternative to maintain a physiological kinematics and reducing the revision rate due to knee instability.

小儿麻痹症患者使用旋转铰链植入物进行全膝关节置换术:临床和功能效果。
对于患有严重膝关节畸形或退化的脊髓灰质炎患者,有关全膝关节置换术(TKR)效果的文献资料很少。有报道称,与限制性较小的假体相比,使用限制性假体(即旋转铰链膝关节假体(RHK))取得了令人鼓舞的结果。本文旨在报告我们使用旋转铰链全膝关节置换术(仅使用 RHK 假体)的经验,以确定脊髓灰质炎患者全膝关节置换术的功能效果、并发症和存活率。我们对 14 名脊髓灰质炎后有膝关节骨性关节炎病史的患者进行了回顾性病历审查,这些患者接受了初级 TKR,共进行了 15 次手术(1 例为双侧手术)。采用膝关节社会评分(KSS)对所有患者进行了术前和术后临床测量。术前和术后使用全负重全景X光片评估了髋膝角、膝关节后角和Insall-Salvati指数。与术前相比,术后两年的临床 KSS 显著改善。平均临床 KSS 从术前的 32.9(范围 3-48)提高到术后的 77.4(范围 60-88)(P 值
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
MUSCULOSKELETAL SURGERY
MUSCULOSKELETAL SURGERY Medicine-Surgery
CiteScore
4.50
自引率
0.00%
发文量
35
期刊介绍: Musculoskeletal Surgery – Formerly La Chirurgia degli Organi di Movimento, founded in 1917 at the Istituto Ortopedico Rizzoli, is a peer-reviewed journal published three times a year. The journal provides up-to-date information to clinicians and scientists through the publication of original papers, reviews, case reports, and brief communications dealing with the pathogenesis and treatment of orthopaedic conditions.An electronic version is also available at http://www.springerlink.com.The journal is open for publication of supplements and for publishing abstracts of scientific meetings; conditions can be obtained from the Editors-in-Chief or the Publisher.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信