Ionic strength-sensitive and pH-insensitive interactions between C-reactive protein (CRP) and an anti-CRP antibody.

Biophysics and Physicobiology Pub Date : 2022-02-09 eCollection Date: 2022-01-01 DOI:10.2142/biophysico.bppb-v19.0003
Yuka Oka, Shota Ushiba, Naruto Miyakawa, Madoka Nishio, Takao Ono, Yasushi Kanai, Yohei Watanabe, Shinsuke Tani, Masahiko Kimura, Kazuhiko Matsumoto
{"title":"Ionic strength-sensitive and pH-insensitive interactions between C-reactive protein (CRP) and an anti-CRP antibody.","authors":"Yuka Oka,&nbsp;Shota Ushiba,&nbsp;Naruto Miyakawa,&nbsp;Madoka Nishio,&nbsp;Takao Ono,&nbsp;Yasushi Kanai,&nbsp;Yohei Watanabe,&nbsp;Shinsuke Tani,&nbsp;Masahiko Kimura,&nbsp;Kazuhiko Matsumoto","doi":"10.2142/biophysico.bppb-v19.0003","DOIUrl":null,"url":null,"abstract":"<p><p>C-reactive protein (CRP) is an important biomarker of infection and inflammation, as CRP is one of the most prominent acute-phase proteins. CRP is usually detected using anti-CRP antibodies (Abs), where the intermolecular interactions between CRP and the anti-CRP Ab are largely affected by the pH and ionic strength of environmental solutions. Therefore, it is important to understand the environmental effects of CRP-anti-CRP Ab interactions when designing highly sensitive biosensors. Here, we investigated the efficiency of fluorescently labeled CRP-anti-CRP monoclonal antibody (mAb) interactions at different pHs and ionic strengths. Our results indicate that the affinity was insensitive to pH changes in the range of 5.9 to 8.1, while it was significantly sensitive to ionic strength changes. The binding affinity decreased by 55% at an ionic strength of 1.6 mM, when compared to that under a physiological condition (~150 mM). Based on the isoelectric focusing results, both the labeled CRP and anti-CRP mAb were negatively charged in the studied pH range, which rendered the system insensitive to pH changes, but sensitive to ionic strength changes. The decreased ionic strength led to a significant enhancement of the repulsive force between CRP and the anti-CRP mAb. Although the versality of the findings is not fully studied yet, the results provide insights into designing highly sensitive CRP sensors, especially field-effect transistor-based sensors.</p>","PeriodicalId":8976,"journal":{"name":"Biophysics and Physicobiology","volume":" ","pages":"e190003"},"PeriodicalIF":0.0000,"publicationDate":"2022-02-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/cc/ec/19_e190003.PMC8926308.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biophysics and Physicobiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2142/biophysico.bppb-v19.0003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

C-reactive protein (CRP) is an important biomarker of infection and inflammation, as CRP is one of the most prominent acute-phase proteins. CRP is usually detected using anti-CRP antibodies (Abs), where the intermolecular interactions between CRP and the anti-CRP Ab are largely affected by the pH and ionic strength of environmental solutions. Therefore, it is important to understand the environmental effects of CRP-anti-CRP Ab interactions when designing highly sensitive biosensors. Here, we investigated the efficiency of fluorescently labeled CRP-anti-CRP monoclonal antibody (mAb) interactions at different pHs and ionic strengths. Our results indicate that the affinity was insensitive to pH changes in the range of 5.9 to 8.1, while it was significantly sensitive to ionic strength changes. The binding affinity decreased by 55% at an ionic strength of 1.6 mM, when compared to that under a physiological condition (~150 mM). Based on the isoelectric focusing results, both the labeled CRP and anti-CRP mAb were negatively charged in the studied pH range, which rendered the system insensitive to pH changes, but sensitive to ionic strength changes. The decreased ionic strength led to a significant enhancement of the repulsive force between CRP and the anti-CRP mAb. Although the versality of the findings is not fully studied yet, the results provide insights into designing highly sensitive CRP sensors, especially field-effect transistor-based sensors.

Abstract Image

Abstract Image

Abstract Image

c -反应蛋白(CRP)和抗CRP抗体之间离子强度敏感和ph不敏感的相互作用。
c -反应蛋白(CRP)是感染和炎症的重要生物标志物,是最重要的急性期蛋白之一。通常使用抗CRP抗体(Abs)检测CRP,其中CRP与抗CRP抗体Ab之间的分子间相互作用在很大程度上受环境溶液的pH和离子强度的影响。因此,在设计高灵敏度生物传感器时,了解CRP-anti-CRP Ab相互作用的环境影响是很重要的。在这里,我们研究了荧光标记的crp -抗crp单克隆抗体(mAb)在不同ph值和离子强度下的相互作用效率。结果表明,亲合力对pH值在5.9 ~ 8.1范围内的变化不敏感,而对离子强度的变化明显敏感。离子强度为1.6 mM时,与生理条件下(~150 mM)的结合亲和力相比,降低了55%。根据等电聚焦结果,标记的CRP和anti-CRP mAb在研究的pH范围内都带负电荷,这使得系统对pH变化不敏感,但对离子强度变化敏感。离子强度的降低导致CRP与抗CRP单抗之间的排斥力显著增强。尽管这些发现的通用性尚未得到充分研究,但结果为设计高灵敏度CRP传感器,特别是基于场效应晶体管的传感器提供了见解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书