The effect of attenuation inside the acoustic traps on the configuration of vertical artifacts in lung ultrasound: an experimental study with simple models.

Journal of Medical Ultrasonics (2001) Pub Date : 2022-10-01 Epub Date: 2022-08-05 DOI:10.1007/s10396-022-01244-0
Toru Kameda, Naohisa Kamiyama, Nobuyuki Taniguchi
{"title":"The effect of attenuation inside the acoustic traps on the configuration of vertical artifacts in lung ultrasound: an experimental study with simple models.","authors":"Toru Kameda,&nbsp;Naohisa Kamiyama,&nbsp;Nobuyuki Taniguchi","doi":"10.1007/s10396-022-01244-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Using simple experimental models for lung ultrasound, we evaluated the relationship of the attenuation inside the sources of vertical artifacts to the echo intensity and attenuation of artifacts.</p><p><strong>Methods: </strong>As sources of artifacts, we made 10 different hemispherical gel objects with two different mediums (pure agar or agar containing graphite with an attenuation coefficient of 0.5 dB/cm · MHz) and five different diameters (3.6, 5.6, 7.5, 9.5, or 11.4 mm). Ten of each hemispherical gel object were prepared for the statistical analyses. Each object was placed onto a chest wall phantom as the plane of the hemisphere was placed in an upward position. The echo intensity and attenuation of the artifact generated from each object was measured and compared.</p><p><strong>Results: </strong>For all sizes, the intensity and attenuation of the artifacts in the objects made of agar containing graphite were significantly lower and larger, respectively, than those in the objects made of pure agar. In the objects containing graphite, the intensity decreased when the frequency was changed from 5 to 9 MHz.</p><p><strong>Conclusion: </strong>Based on this experiment, assessing the intensity and attenuation of vertical artifacts may help estimate the physical composition of sources of vertical artifacts in lung ultrasound.</p>","PeriodicalId":111320,"journal":{"name":"Journal of Medical Ultrasonics (2001)","volume":" ","pages":"545-553"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9362371/pdf/","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Ultrasonics (2001)","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10396-022-01244-0","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/8/5 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Purpose: Using simple experimental models for lung ultrasound, we evaluated the relationship of the attenuation inside the sources of vertical artifacts to the echo intensity and attenuation of artifacts.

Methods: As sources of artifacts, we made 10 different hemispherical gel objects with two different mediums (pure agar or agar containing graphite with an attenuation coefficient of 0.5 dB/cm · MHz) and five different diameters (3.6, 5.6, 7.5, 9.5, or 11.4 mm). Ten of each hemispherical gel object were prepared for the statistical analyses. Each object was placed onto a chest wall phantom as the plane of the hemisphere was placed in an upward position. The echo intensity and attenuation of the artifact generated from each object was measured and compared.

Results: For all sizes, the intensity and attenuation of the artifacts in the objects made of agar containing graphite were significantly lower and larger, respectively, than those in the objects made of pure agar. In the objects containing graphite, the intensity decreased when the frequency was changed from 5 to 9 MHz.

Conclusion: Based on this experiment, assessing the intensity and attenuation of vertical artifacts may help estimate the physical composition of sources of vertical artifacts in lung ultrasound.

Abstract Image

Abstract Image

Abstract Image

肺超声声阱内衰减对垂直伪影形态的影响:简单模型实验研究。
目的:利用简单的肺超声实验模型,评估垂直伪影源内的衰减与伪影回波强度和衰减的关系。方法:作为人工制品的来源,我们用两种不同的培养基(纯琼脂或含石墨的琼脂,衰减系数为0.5 dB/cm·MHz)和5种不同的直径(3.6,5.6,7.5,9.5,11.4 mm)制作了10种不同的半球形凝胶制品。每种半球形凝胶体各制备10个用于统计分析。当半球平面向上放置时,将每个物体放置在胸壁幻象上。测量和比较了每个目标产生的伪影的回波强度和衰减。结果:对于各种尺寸,含石墨琼脂制品的伪影强度明显小于纯琼脂制品,衰减明显大于纯琼脂制品。在含石墨的物体中,当频率从5 MHz变化到9 MHz时,强度减小。结论:基于本实验,评估垂直伪影的强度和衰减有助于估计肺部超声垂直伪影源的物理组成。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书