Multipurpose Lens Care Systems and Silicone Hydrogel Contact Lens Wettability: A Systematic Review.

Eye & Contact Lens Pub Date : 2022-09-01 Epub Date: 2022-06-30 DOI:10.1097/ICL.0000000000000914
Raúl Capote-Puente, José-María Sánchez-González, María-José Bautista-Llamas
{"title":"Multipurpose Lens Care Systems and Silicone Hydrogel Contact Lens Wettability: A Systematic Review.","authors":"Raúl Capote-Puente,&nbsp;José-María Sánchez-González,&nbsp;María-José Bautista-Llamas","doi":"10.1097/ICL.0000000000000914","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To provide a relationship between materials developed for silicone hydrogel contact lenses and multipurpose care solutions to identify improvements in wettability, for prelens noninvasive break-up time and subjective score.</p><p><strong>Methods: </strong>This systematic review was completed according to the updated PRISMA 2020 statement recommendations and followed the explanation and elaboration guidelines. The PubMed, Web of Science, and Scopus scientific literature databases were searched from January 2000 to November 2021.</p><p><strong>Results: </strong>A total of four clinical trials published between 2011 and 2017 were included in this investigation. All included studies were randomized clinical trials. The success of contact lenses is related to the comfort of their use and therefore to the stability of the tear film and the wettability of its surface. The relationship between these parameters and changes in the ocular surface and inflammatory and infectious processes has been demonstrated.</p><p><strong>Conclusion: </strong>Hyaluronan and propylene glycol multipurpose solution (MPS) wetting agents achieved slightly higher prelens noninvasive break-up times than poloxamine. Polyquaternium-1 achieved better wettability and patient comfort than polyhexamethylene biguanide in medium-term studies. Short-term studies did not demonstrate differences between MPSs in their effect on contact lens wettability.</p>","PeriodicalId":502139,"journal":{"name":"Eye & Contact Lens","volume":" ","pages":"356-361"},"PeriodicalIF":0.0000,"publicationDate":"2022-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye & Contact Lens","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/ICL.0000000000000914","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/6/30 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Purpose: To provide a relationship between materials developed for silicone hydrogel contact lenses and multipurpose care solutions to identify improvements in wettability, for prelens noninvasive break-up time and subjective score.

Methods: This systematic review was completed according to the updated PRISMA 2020 statement recommendations and followed the explanation and elaboration guidelines. The PubMed, Web of Science, and Scopus scientific literature databases were searched from January 2000 to November 2021.

Results: A total of four clinical trials published between 2011 and 2017 were included in this investigation. All included studies were randomized clinical trials. The success of contact lenses is related to the comfort of their use and therefore to the stability of the tear film and the wettability of its surface. The relationship between these parameters and changes in the ocular surface and inflammatory and infectious processes has been demonstrated.

Conclusion: Hyaluronan and propylene glycol multipurpose solution (MPS) wetting agents achieved slightly higher prelens noninvasive break-up times than poloxamine. Polyquaternium-1 achieved better wettability and patient comfort than polyhexamethylene biguanide in medium-term studies. Short-term studies did not demonstrate differences between MPSs in their effect on contact lens wettability.

多用途隐形眼镜护理系统和硅水凝胶隐形眼镜润湿性:系统综述。
目的:提供硅胶水凝胶隐形眼镜材料与多用途护理溶液之间的关系,以确定润湿性,晶状体前无创破裂时间和主观评分的改善。方法:本系统综述按照更新后的PRISMA 2020声明建议完成,并遵循解释和阐述指南。检索了2000年1月至2021年11月期间的PubMed、Web of Science和Scopus科学文献数据库。结果:本研究共纳入2011 - 2017年发表的4项临床试验。所有纳入的研究均为随机临床试验。隐形眼镜的成功与使用的舒适性有关,因此与泪膜的稳定性和表面的润湿性有关。这些参数与眼表变化以及炎症和感染过程之间的关系已得到证实。结论:透明质酸和丙二醇多用途溶液(MPS)润湿剂的无创破眼时间略高于poloxamine。在中期研究中,聚季铵盐-1比聚六亚甲基双胍具有更好的润湿性和患者舒适度。短期研究没有证明mps对隐形眼镜润湿性的影响存在差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书