Effectiveness of a voiding evaluation technique using a diaper equipped with a urination-activated alarm system to assess bladder function and voiding patterns in infants.

Journal of Medical Ultrasonics (2001) Pub Date : 2022-10-01 Epub Date: 2022-08-23 DOI:10.1007/s10396-022-01251-1
Jun Ajiki, Yasuyuki Naitoh, Yuta Inoue, Tsukasa Narukawa, Atsuko Fujihara, Fumiya Hongo, Osamu Ukimura
{"title":"Effectiveness of a voiding evaluation technique using a diaper equipped with a urination-activated alarm system to assess bladder function and voiding patterns in infants.","authors":"Jun Ajiki, Yasuyuki Naitoh, Yuta Inoue, Tsukasa Narukawa, Atsuko Fujihara, Fumiya Hongo, Osamu Ukimura","doi":"10.1007/s10396-022-01251-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Four-hour voiding observation is a conventional method for evaluating bladder function in infants. However, it requires a diaper check every 5 min during the observation period, which creates an unusual environment for the infant, making the evaluation of natural urination difficult. This study aimed to investigate the parameters of urination before mature bladder function using a diaper equipped with a urination-activated alarm system.</p><p><strong>Methods: </strong>The study participants were 51 infants aged 0-4 years without bladder dysfunction. A urination-activated sensor was used to notify the inspector wirelessly when urination was detected, enabling the immediate assessment of ultrasonically measured residual urine. Bladder capacity was calculated as the sum of both residual urine volume and micturition volume, and the residual urine rate as the residual urine volume divided by bladder capacity.</p><p><strong>Results: </strong>A total of 36 boys and 15 girls were enrolled. The median (interquartile range) residual urine volume, bladder capacity, and residual urine rate were 3.0 mL (1.1-6.6), 53.0 mL (33.9-75.3), and 7.0% (2.1-15.0), respectively. Infants aged 0-1 and 2-4 years were then classified into Group A (N = 27) and Group B (N = 24), respectively. The residual urine rate was significantly higher in Group A (11.0% [5.4-21.2]) than in Group B (4.8% [0.6-8.9]; p < 0.01).</p><p><strong>Conclusions: </strong>Voiding observation using a urination-activated alarm system allowed less invasive analysis in infants and revealed that the residual urine rate decreased with mature bladder function from about 2 years of age.</p>","PeriodicalId":111320,"journal":{"name":"Journal of Medical Ultrasonics (2001)","volume":" ","pages":"695-701"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Medical Ultrasonics (2001)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s10396-022-01251-1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/8/23 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Four-hour voiding observation is a conventional method for evaluating bladder function in infants. However, it requires a diaper check every 5 min during the observation period, which creates an unusual environment for the infant, making the evaluation of natural urination difficult. This study aimed to investigate the parameters of urination before mature bladder function using a diaper equipped with a urination-activated alarm system.

Methods: The study participants were 51 infants aged 0-4 years without bladder dysfunction. A urination-activated sensor was used to notify the inspector wirelessly when urination was detected, enabling the immediate assessment of ultrasonically measured residual urine. Bladder capacity was calculated as the sum of both residual urine volume and micturition volume, and the residual urine rate as the residual urine volume divided by bladder capacity.

Results: A total of 36 boys and 15 girls were enrolled. The median (interquartile range) residual urine volume, bladder capacity, and residual urine rate were 3.0 mL (1.1-6.6), 53.0 mL (33.9-75.3), and 7.0% (2.1-15.0), respectively. Infants aged 0-1 and 2-4 years were then classified into Group A (N = 27) and Group B (N = 24), respectively. The residual urine rate was significantly higher in Group A (11.0% [5.4-21.2]) than in Group B (4.8% [0.6-8.9]; p < 0.01).

Conclusions: Voiding observation using a urination-activated alarm system allowed less invasive analysis in infants and revealed that the residual urine rate decreased with mature bladder function from about 2 years of age.

使用配备排尿激活报警系统的纸尿裤评估婴儿膀胱功能和排尿模式的有效性。
目的:4小时排尿观察是评价婴幼儿膀胱功能的常规方法。然而,在观察期间需要每5分钟检查一次尿布,这给婴儿创造了一个不寻常的环境,使自然排尿的评估变得困难。本研究旨在探讨膀胱功能成熟前的尿尿参数,使用配备尿尿激活报警系统的纸尿裤。方法:研究对象为51例0 ~ 4岁无膀胱功能障碍的婴儿。当检测到排尿时,使用排尿激活传感器无线通知检查人员,从而可以立即评估超声测量的残余尿液。膀胱容量计算为残尿量与排尿量之和,残尿率计算为残尿量除以膀胱容量。结果:共纳入36名男生和15名女生。残尿量、膀胱容量和残尿率中位数(四分位数间距)分别为3.0 mL(1.1 ~ 6.6)、53.0 mL(33.9 ~ 75.3)和7.0%(2.1 ~ 15.0)。0 ~ 1岁和2 ~ 4岁婴幼儿分别分为A组27例和B组24例。A组残尿率(11.0%[5.4-21.2])明显高于B组(4.8% [0.6-8.9]);p结论:使用尿激活报警系统进行排尿观察,可以减少对婴儿的侵入性分析,并显示残尿率从2岁左右开始随着膀胱功能的成熟而下降。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书