Seema S Bhat, Pavan Poojar, Chennagiri Rajarao Padma, Rishi Kashyap Ananth, M C Hanumantharaju, Sairam Geethanath
{"title":"Deep Learning-Based Denoising for High b-Value at 2000 s/mm2 Diffusion-Weighted Imaging.","authors":"Seema S Bhat, Pavan Poojar, Chennagiri Rajarao Padma, Rishi Kashyap Ananth, M C Hanumantharaju, Sairam Geethanath","doi":"10.1615/CritRevBiomedEng.2022040279","DOIUrl":null,"url":null,"abstract":"<p><p>Diffusion-weighted imaging (DWI) allows white matter quantification of the white matter tracts of the brain. However, at a high b-value (≥ 2000 s/mm2), DWI acquisition suffers from noise due to longer acquisition times obscuring white matter interpretation. DWI denoising techniques can be used to acquire high b-value DWI without increasing the number of signal averages. We used a residual learning-based convolutional neural network (DnCNN) to reduce noise in high b-value DWI based on the literature review. We applied the proposed denoising method on high b-value, retrospectively collected DWI data with multiple noise levels. Experimental results show an improved image quality after denoising in retrospective DWI (average PSNR before and after denoising: 27.63 ± 1.06 dB and 51.76 ± 1.95 dB, respectively). The prospective DWI included one and two signal averages for denoising. DWI with four signal averages was used as the reference. Representative images show high b-value prospective DW images denoised using the DnCNN. We demonstrated DnCNN for cases of multiple noise levels and signal averages. For the prospective study, the PSNR values for 1-NEX before and after denoising were 27.39 ± 3.75 dB and 27.68 ± 3.75 dB. For 2-NEX, the PSNR values before and after denoising were 27.51 ± 4.18 dB and 27.75 ± 4.05 dB.</p>","PeriodicalId":53679,"journal":{"name":"Critical Reviews in Biomedical Engineering","volume":"49 6","pages":"1-10"},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Critical Reviews in Biomedical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1615/CritRevBiomedEng.2022040279","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0
Abstract
Diffusion-weighted imaging (DWI) allows white matter quantification of the white matter tracts of the brain. However, at a high b-value (≥ 2000 s/mm2), DWI acquisition suffers from noise due to longer acquisition times obscuring white matter interpretation. DWI denoising techniques can be used to acquire high b-value DWI without increasing the number of signal averages. We used a residual learning-based convolutional neural network (DnCNN) to reduce noise in high b-value DWI based on the literature review. We applied the proposed denoising method on high b-value, retrospectively collected DWI data with multiple noise levels. Experimental results show an improved image quality after denoising in retrospective DWI (average PSNR before and after denoising: 27.63 ± 1.06 dB and 51.76 ± 1.95 dB, respectively). The prospective DWI included one and two signal averages for denoising. DWI with four signal averages was used as the reference. Representative images show high b-value prospective DW images denoised using the DnCNN. We demonstrated DnCNN for cases of multiple noise levels and signal averages. For the prospective study, the PSNR values for 1-NEX before and after denoising were 27.39 ± 3.75 dB and 27.68 ± 3.75 dB. For 2-NEX, the PSNR values before and after denoising were 27.51 ± 4.18 dB and 27.75 ± 4.05 dB.
期刊介绍:
Biomedical engineering has been characterized as the application of concepts drawn from engineering, computing, communications, mathematics, and the physical sciences to scientific and applied problems in the field of medicine and biology. Concepts and methodologies in biomedical engineering extend throughout the medical and biological sciences. This journal attempts to critically review a wide range of research and applied activities in the field. More often than not, topics chosen for inclusion are concerned with research and practice issues of current interest. Experts writing each review bring together current knowledge and historical information that has led to the current state-of-the-art.