In vivo knee kinematics of an innovative prosthesis design.

IF 1.6
Open medicine (Warsaw, Poland) Pub Date : 2022-07-20 eCollection Date: 2022-01-01 DOI:10.1515/med-2022-0518
Michael Worlicek, Jens Schaumburger, Robert Springorum, Guenther Maderbacher, Florian Zeman, Joachim Grifka, Clemens Baier
{"title":"<i>In vivo</i> knee kinematics of an innovative prosthesis design.","authors":"Michael Worlicek,&nbsp;Jens Schaumburger,&nbsp;Robert Springorum,&nbsp;Guenther Maderbacher,&nbsp;Florian Zeman,&nbsp;Joachim Grifka,&nbsp;Clemens Baier","doi":"10.1515/med-2022-0518","DOIUrl":null,"url":null,"abstract":"<p><p>Up to 20% of patients after total knee arthroplasty (TKA) are not satisfied with the result. Several designs of new implants try to rebuild natural knee kinematics. We hypothesized that an innovative implant design leads to better results concerning femoral rollback compared to an established implant design. For this pilot study, 21 patients were examined during TKA, receiving either an innovative (ATTUNE<sup>TM</sup> Knee System (DePuy Inc.), <i>n</i> = 10) or an established (PFC<sup>TM</sup> (DePuy Inc.), <i>n</i> = 11) knee system. All patients underwent computer navigation. Knee kinematics was assessed after implantation. Outcome measure was anterior-posterior translation between femur and tibia. We were able to demonstrate a significantly higher femoral rollback in the innovative implant group (<i>p</i> < 0.001). The mean rollback of the innovative system was 11.00 mm (95%-confidence interval [CI], 10.77-11.24), of the established system 8.12 mm (95%-CI, 7.84-8.42). This study revealed a significantly increased lateral as well as medial femoral rollback of knees with the innovative prosthesis design. Our intraoperative finding needs to be confirmed using fluoroscopic or radiographic three-dimensional matching under full-weight-bearing conditions after complete recovery from surgery.</p>","PeriodicalId":520729,"journal":{"name":"Open medicine (Warsaw, Poland)","volume":" ","pages":"1318-1324"},"PeriodicalIF":1.6000,"publicationDate":"2022-07-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9307144/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open medicine (Warsaw, Poland)","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1515/med-2022-0518","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Up to 20% of patients after total knee arthroplasty (TKA) are not satisfied with the result. Several designs of new implants try to rebuild natural knee kinematics. We hypothesized that an innovative implant design leads to better results concerning femoral rollback compared to an established implant design. For this pilot study, 21 patients were examined during TKA, receiving either an innovative (ATTUNETM Knee System (DePuy Inc.), n = 10) or an established (PFCTM (DePuy Inc.), n = 11) knee system. All patients underwent computer navigation. Knee kinematics was assessed after implantation. Outcome measure was anterior-posterior translation between femur and tibia. We were able to demonstrate a significantly higher femoral rollback in the innovative implant group (p < 0.001). The mean rollback of the innovative system was 11.00 mm (95%-confidence interval [CI], 10.77-11.24), of the established system 8.12 mm (95%-CI, 7.84-8.42). This study revealed a significantly increased lateral as well as medial femoral rollback of knees with the innovative prosthesis design. Our intraoperative finding needs to be confirmed using fluoroscopic or radiographic three-dimensional matching under full-weight-bearing conditions after complete recovery from surgery.

Abstract Image

Abstract Image

一种创新假体设计的体内膝关节运动学。
高达20%的患者在全膝关节置换术(TKA)后不满意的结果。几种新植入物的设计试图重建膝关节的自然运动学。我们假设,与现有的植入物设计相比,创新的植入物设计可以带来更好的股骨回退效果。在这项初步研究中,21名患者在TKA期间接受检查,接受创新的(ATTUNETM膝关节系统(DePuy公司),n = 10)或已建立的(PFCTM (DePuy公司),n = 11)膝关节系统。所有患者均行计算机导航。植入后评估膝关节运动学。结果测量股骨和胫骨之间的前后平移。我们能够证明创新植入物组的股骨回退明显更高(p < 0.001)。创新系统的平均回退量为11.00 mm(95%可信区间[CI], 10.77 ~ 11.24),建立系统的平均回退量为8.12 mm(95%可信区间[CI], 7.84 ~ 8.42)。该研究显示,采用创新假体设计后,膝关节外侧和内侧股骨回退明显增加。我们的术中发现需要在手术完全恢复后全负重条件下使用透视或x线片三维匹配来证实。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书