Utility of Measuring Fetal Cavum Septum Pellucidum (CSP) Width During Routine Obstetrical Ultrasound for Improving Diagnosis of 22q11.2 Deletion Syndrome: A Case-Control Study.

The Application of Clinical Genetics Pub Date : 2022-07-26 eCollection Date: 2022-01-01 DOI:10.2147/TACG.S364543
Christy L Pylypjuk, Shiza F Memon, Bernard N Chodirker
{"title":"Utility of Measuring Fetal Cavum Septum Pellucidum (CSP) Width During Routine Obstetrical Ultrasound for Improving Diagnosis of 22q11.2 Deletion Syndrome: A Case-Control Study.","authors":"Christy L Pylypjuk,&nbsp;Shiza F Memon,&nbsp;Bernard N Chodirker","doi":"10.2147/TACG.S364543","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the utility of measuring fetal cavum septum pellucidum (CSP) width during routine, mid-pregnancy ultrasound for improving diagnosis of 22q11.2 deletion syndrome amongst fetuses with and without conotruncal anomalies.</p><p><strong>Patients and methods: </strong>This was a retrospective case-control study (2005-2016). Fetuses and newborns with 22q11.2 deletion and/or conotruncal cardiac anomalies were identified using a regional, clinical database. A control group was assembled in a 2:1 ratio to create three groups for comparison: i) 22q11.2 deletion syndrome; ii) isolated conotruncal anomalies; and iii) controls. Eligibility was restricted to those with stored ultrasound images between 18-22 weeks' gestation and a minimum biparietal diameter of 40 mm. Post-processing measurement of CSP width was performed in a standardized fashion by two blinded and independent study personnel. Descriptive and inferential statistics, regression modeling, and receiver operator curves (ROC) were used to compare outcomes between groups and evaluate sensitivity/specificity of CSP width as a marker of 22q11.2 deletion syndrome.</p><p><strong>Results: </strong>Twenty-nine cases of 22q11.2 deletion and 64 cases of isolated conotruncal anomalies were matched to 186 healthy controls. Cases with 22q11.2 deletion syndrome had significantly larger CSP widths (5.36 mm; SD=1.2) compared to those with isolated conotruncal anomalies (3.75 mm; SD=1.11) and healthy controls (2.93 mm; SD=0.57; <i>p</i><0.0001). There was no difference in CSP width amongst those with 22q11.2 deletion irrespective of the presence/absence of a conotruncal anomaly (<i>p</i>=0.362), or by type of conotruncal anomaly (<i>p</i>=0.211). Using a CSP width cutoff >4.3 mm, fetuses with 22q11.2 deletion can be accurately identified with good sensitivity (89.7%) and specificity (84%).</p><p><strong>Conclusion: </strong>Fetuses with 22q11.2 deletion syndrome have dilated CSPs when compared to those with isolated conotruncal anomalies or controls. Because CSP dilation can be evaluated during routine mid-pregnancy ultrasound using standard images of the fetal head, measurement could easily be incorporated to enhance prenatal diagnosis of this phenotypically diverse condition.</p>","PeriodicalId":506374,"journal":{"name":"The Application of Clinical Genetics","volume":" ","pages":"87-95"},"PeriodicalIF":0.0000,"publicationDate":"2022-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/90/b2/tacg-15-87.PMC9341354.pdf","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Application of Clinical Genetics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/TACG.S364543","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

Objective: To evaluate the utility of measuring fetal cavum septum pellucidum (CSP) width during routine, mid-pregnancy ultrasound for improving diagnosis of 22q11.2 deletion syndrome amongst fetuses with and without conotruncal anomalies.

Patients and methods: This was a retrospective case-control study (2005-2016). Fetuses and newborns with 22q11.2 deletion and/or conotruncal cardiac anomalies were identified using a regional, clinical database. A control group was assembled in a 2:1 ratio to create three groups for comparison: i) 22q11.2 deletion syndrome; ii) isolated conotruncal anomalies; and iii) controls. Eligibility was restricted to those with stored ultrasound images between 18-22 weeks' gestation and a minimum biparietal diameter of 40 mm. Post-processing measurement of CSP width was performed in a standardized fashion by two blinded and independent study personnel. Descriptive and inferential statistics, regression modeling, and receiver operator curves (ROC) were used to compare outcomes between groups and evaluate sensitivity/specificity of CSP width as a marker of 22q11.2 deletion syndrome.

Results: Twenty-nine cases of 22q11.2 deletion and 64 cases of isolated conotruncal anomalies were matched to 186 healthy controls. Cases with 22q11.2 deletion syndrome had significantly larger CSP widths (5.36 mm; SD=1.2) compared to those with isolated conotruncal anomalies (3.75 mm; SD=1.11) and healthy controls (2.93 mm; SD=0.57; p<0.0001). There was no difference in CSP width amongst those with 22q11.2 deletion irrespective of the presence/absence of a conotruncal anomaly (p=0.362), or by type of conotruncal anomaly (p=0.211). Using a CSP width cutoff >4.3 mm, fetuses with 22q11.2 deletion can be accurately identified with good sensitivity (89.7%) and specificity (84%).

Conclusion: Fetuses with 22q11.2 deletion syndrome have dilated CSPs when compared to those with isolated conotruncal anomalies or controls. Because CSP dilation can be evaluated during routine mid-pregnancy ultrasound using standard images of the fetal head, measurement could easily be incorporated to enhance prenatal diagnosis of this phenotypically diverse condition.

Abstract Image

Abstract Image

Abstract Image

在常规产科超声中测量胎儿透明隔腔(CSP)宽度对提高22q11.2缺失综合征诊断的作用:一项病例对照研究。
目的:探讨在妊娠中期常规超声中测量胎儿透明隔腔(CSP)宽度对有或无conotruncal异常胎儿22q11.2缺失综合征的诊断价值。患者和方法:本研究为回顾性病例对照研究(2005-2016)。22q11.2缺失和/或锥形心脏异常的胎儿和新生儿使用区域性临床数据库进行鉴定。对照组按2:1的比例组成三组进行比较:i) 22q11.2缺失综合征;Ii)孤立的圆锥锥体异常;iii)控制。资格仅限于妊娠18-22周之间存储超声图像且双顶骨直径最小为40 mm的患者。CSP宽度的后处理测量由两名独立的盲法研究人员以标准化的方式进行。采用描述性和推断性统计、回归模型和受试者操作曲线(ROC)来比较两组间的结果,并评估CSP宽度作为22q11.2缺失综合征标志物的敏感性/特异性。结果:29例22q11.2缺失和64例孤立锥体异常与186例健康对照相匹配。22q11.2缺失综合征患者CSP宽度显著增大(5.36 mm;与孤立的圆锥截骨异常(3.75 mm;SD=1.11)和健康对照组(2.93 mm;SD = 0.57;Pp =0.362),或按锥体异常类型划分(p=0.211)。使用CSP宽度临界值>4.3 mm,可以准确识别22q11.2缺失的胎儿,具有良好的灵敏度(89.7%)和特异性(84%)。结论:22q11.2缺失综合征的胎儿与孤立的圆锥锥体异常或对照组相比,csp扩张。由于CSP扩张可以在常规妊娠中期超声中使用胎儿头部的标准图像进行评估,因此测量可以很容易地纳入产前诊断,以增强这种表型多样化的疾病。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书