A three-portal laparoscopic hysterectomy in a chimpanzee (Pan troglodytes) with a uterine manipulator and vessel sealing device.

Veterinary surgery : VS Pub Date : 2022-10-01 Epub Date: 2022-07-28 DOI:10.1111/vsu.13856
Jasmine Y Sarvi, Sara M Gardhouse, Kara A Berke, Rebeka L Weber, Kara Hiebert, John H Whittaker, Nathaniel Kapaldo
{"title":"A three-portal laparoscopic hysterectomy in a chimpanzee (Pan troglodytes) with a uterine manipulator and vessel sealing device.","authors":"Jasmine Y Sarvi,&nbsp;Sara M Gardhouse,&nbsp;Kara A Berke,&nbsp;Rebeka L Weber,&nbsp;Kara Hiebert,&nbsp;John H Whittaker,&nbsp;Nathaniel Kapaldo","doi":"10.1111/vsu.13856","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To report the treatment and outcome of a a captive chimpanzee (Pan troglodytes) undergoing 3-portal laparoscopic hysterectomy. Additionally, the technique used for successful urinary catheterization is described.</p><p><strong>Animals: </strong>A 29-year-old female intact chimpanzee with uterine bleeding.</p><p><strong>Study design: </strong>Clinical case report.</p><p><strong>Methods: </strong>Uterine changes consistent with adenomyosis and/or endometriosis were noted on abdominal ultrasonographic and computed tomographic examinations. A urinary catheter was placed before a 3-portal laparoscopic hysterectomy with a uterine manipulator (VCare) and a vessel sealer (Ligasure). The uterus was submitted for histopathology.</p><p><strong>Results: </strong>Preoperative urinary catheterization was achieved with several modifications and prevented bladder protrusion into the surgical field. Laparoscopy provided excellent visualization of the pelvic structures and VCare effectively maneuvered the uterus for a safe and efficient dissection. The use of the vessel sealer was effective, and bleeding was minimal. Anesthesia and surgery lasted 240 and 150 minutes, respectively. No complications were encountered. Histopathological changes of the uterus were consistent with adenomyosis and myometrial hyperplasia. The chimpanzee recovered uneventfully and returned to normal behavior with no recurrence of uterine bleeding 5 months after surgery.</p><p><strong>Conclusion: </strong>The 3-portal laparoscopic technique reported here allowed hysterectomy without complication in this chimpanzee. Urinary catheterization was technically challenging but successful.</p>","PeriodicalId":123280,"journal":{"name":"Veterinary surgery : VS","volume":" ","pages":"1167-1174"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary surgery : VS","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1111/vsu.13856","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/7/28 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To report the treatment and outcome of a a captive chimpanzee (Pan troglodytes) undergoing 3-portal laparoscopic hysterectomy. Additionally, the technique used for successful urinary catheterization is described.

Animals: A 29-year-old female intact chimpanzee with uterine bleeding.

Study design: Clinical case report.

Methods: Uterine changes consistent with adenomyosis and/or endometriosis were noted on abdominal ultrasonographic and computed tomographic examinations. A urinary catheter was placed before a 3-portal laparoscopic hysterectomy with a uterine manipulator (VCare) and a vessel sealer (Ligasure). The uterus was submitted for histopathology.

Results: Preoperative urinary catheterization was achieved with several modifications and prevented bladder protrusion into the surgical field. Laparoscopy provided excellent visualization of the pelvic structures and VCare effectively maneuvered the uterus for a safe and efficient dissection. The use of the vessel sealer was effective, and bleeding was minimal. Anesthesia and surgery lasted 240 and 150 minutes, respectively. No complications were encountered. Histopathological changes of the uterus were consistent with adenomyosis and myometrial hyperplasia. The chimpanzee recovered uneventfully and returned to normal behavior with no recurrence of uterine bleeding 5 months after surgery.

Conclusion: The 3-portal laparoscopic technique reported here allowed hysterectomy without complication in this chimpanzee. Urinary catheterization was technically challenging but successful.

使用子宫操纵器和血管密封装置的黑猩猩(类人猿)三门腹腔镜子宫切除术。
目的:报道一只圈养黑猩猩(类人猿)接受三门腹腔镜子宫切除术的治疗和结果。此外,用于成功导尿的技术也被描述。动物:一只子宫出血的29岁雌性完整黑猩猩。研究设计:临床病例报告。方法:在腹部超声和计算机断层检查中发现子宫改变与子宫腺肌病和/或子宫内膜异位症一致。在使用子宫操纵器(VCare)和血管密封器(Ligasure)进行三门腹腔镜子宫切除术前放置导尿管。子宫行组织病理学检查。结果:术前导尿经过多次修改,防止了膀胱突出进入手术野。腹腔镜提供了良好的骨盆结构可视化,VCare有效地操纵子宫进行安全有效的剥离。血管密封剂的使用是有效的,出血是最小的。麻醉和手术时间分别为240分钟和150分钟。无并发症发生。子宫组织病理学改变与子宫腺肌病和子宫肌瘤增生一致。手术后5个月,这只黑猩猩平静地恢复了正常的行为,没有子宫出血复发。结论:本文报道的三门静脉腹腔镜技术使该黑猩猩的子宫切除术无并发症。导尿术在技术上具有挑战性,但很成功。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信