Modular operating theater based integration system in hospital operating rooms.

Andiyan Andiyan, I Made Raka, Masayu Rosyidah, Santi Salayanti, Pandu Adi Cakranegara, Rini Nuraini
{"title":"Modular operating theater based integration system in hospital operating rooms.","authors":"Andiyan Andiyan,&nbsp;I Made Raka,&nbsp;Masayu Rosyidah,&nbsp;Santi Salayanti,&nbsp;Pandu Adi Cakranegara,&nbsp;Rini Nuraini","doi":"10.47750/jptcp.2022.936","DOIUrl":null,"url":null,"abstract":"<p><p>The modular operating theater (MOT) system is often used in operating rooms since it is incorporated into a single control panel, enabling its operation more effectively and efficiently. The MOT in the present study's operating room employs analytical techniques, and moreover has complicated space needs. Any hospital that wants to implement MOT in the operating room must adhere to the regulations of the Indonesian Ministry of Health, as everything must adhere to a specific criteria. Additionally, MOT must fulfill the primary components required to ensure that the operational process proceeds properly and without technological difficulties. The criteria also includes the use of insulated doors (swing or sliding) to control the pathogens, bacteriostatic floors with corner covings, the operating table must be set in such a way that the laminar airflow reaches it, the use of modern operating tables, the adequate filtration of the air conditioning system and the air distribution system, and use of sterile corridors. The MOT in the operating room must also include the medical gas pipeline system (MGPS), flexible arm light pendants, precise indications on surgeon control panels and electrical panels, scrub stations, comprehensive utility pendants, as well as static/dynamic clean/dirty boxes. The operating room MOT requirements are specified in PERMENKES RI No. 1204/MENKES/SK/X/2004, and any hospital that wishes to construct one must adhere to them. Several requirements are outlined in the study that must be adhered to while manufacturing MOT. For example, walls and ceilings must be insulated with PUF, EPS, or stainless steel panels.</p>","PeriodicalId":73904,"journal":{"name":"Journal of population therapeutics and clinical pharmacology = Journal de la therapeutique des populations et de la pharmacologie clinique","volume":"29 2","pages":"e104-e114"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of population therapeutics and clinical pharmacology = Journal de la therapeutique des populations et de la pharmacologie clinique","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47750/jptcp.2022.936","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The modular operating theater (MOT) system is often used in operating rooms since it is incorporated into a single control panel, enabling its operation more effectively and efficiently. The MOT in the present study's operating room employs analytical techniques, and moreover has complicated space needs. Any hospital that wants to implement MOT in the operating room must adhere to the regulations of the Indonesian Ministry of Health, as everything must adhere to a specific criteria. Additionally, MOT must fulfill the primary components required to ensure that the operational process proceeds properly and without technological difficulties. The criteria also includes the use of insulated doors (swing or sliding) to control the pathogens, bacteriostatic floors with corner covings, the operating table must be set in such a way that the laminar airflow reaches it, the use of modern operating tables, the adequate filtration of the air conditioning system and the air distribution system, and use of sterile corridors. The MOT in the operating room must also include the medical gas pipeline system (MGPS), flexible arm light pendants, precise indications on surgeon control panels and electrical panels, scrub stations, comprehensive utility pendants, as well as static/dynamic clean/dirty boxes. The operating room MOT requirements are specified in PERMENKES RI No. 1204/MENKES/SK/X/2004, and any hospital that wishes to construct one must adhere to them. Several requirements are outlined in the study that must be adhered to while manufacturing MOT. For example, walls and ceilings must be insulated with PUF, EPS, or stainless steel panels.

基于模块化手术室的医院手术室集成系统。
模块化手术室(MOT)系统通常用于手术室,因为它被整合到一个单一的控制面板中,使其操作更加有效和高效。本研究的手术室MOT采用分析技术,且空间需求复杂。任何想要在手术室实施MOT的医院都必须遵守印度尼西亚卫生部的规定,因为一切都必须遵守特定的标准。此外,MOT必须满足确保操作过程正确进行并且没有技术困难所需的主要组件。标准还包括使用隔热门(摆动或滑动)来控制病原体,带角口的杀菌地板,手术台必须以层流气流到达的方式设置,使用现代手术台,对空调系统和空气分配系统进行充分过滤,并使用无菌走廊。手术室的MOT还必须包括医用气体管道系统(MGPS)、柔性臂灯挂件、外科医生控制面板和电气面板上的精确指示、擦洗台、综合公用事业挂件以及静态/动态清洁/脏盒。PERMENKES RI第1204/MENKES/SK/X/2004号规定了手术室的MOT要求,任何希望建造手术室的医院都必须遵守这些要求。研究中概述了在制造MOT时必须遵守的几个要求。例如,墙壁和天花板必须用PUF, EPS或不锈钢板绝缘。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信