Low Incidence of Prosthesis-Patient Mismatch Following Extremely Small Transcatheter Aortic Valve Replacement with 20-mm Sapien 3.

IF 0.9
Kazue Okajima, Ikki Komatsu, Todd B Seto
{"title":"Low Incidence of Prosthesis-Patient Mismatch Following Extremely Small Transcatheter Aortic Valve Replacement with 20-mm Sapien 3.","authors":"Kazue Okajima,&nbsp;Ikki Komatsu,&nbsp;Todd B Seto","doi":"10.1055/s-0041-1732316","DOIUrl":null,"url":null,"abstract":"<p><p>Transcatheter aortic valve replacement has been developed as an emerging technique to treat patients with aortic valve disease. However, safety and outcome data on extremely small transcatheter heart valves (THV) is limited. We aimed to assess hemodynamic profiles and clinical outcome of very small balloon expandable THVs with 20-mm Sapien 3 (SP3). We examined data for all patients who received third-generation SP3 THV at a single hospital. Complications and clinical outcomes were defined based on the VARC-2 criteria. Postoperative prosthesis-patient mismatch (PPM) was defined as indexed effective orifice area (EOA) < 0.85 cm <sup>2</sup> /m <sup>2</sup> . We compared clinical characteristics and outcome between patients with 20-mm ( <i>n</i>  = 21), 23-mm ( <i>n</i>  = 67), and 26- or 29-mm ( <i>n</i>  = 113) sized valves. The 20-mm group included significantly higher number of Asian and female populations with lower body surface area. The baseline CT annular area in the 20-mm group was 316.5 ± 24.9 mm <sup>2</sup> . There was no significant difference between groups in procedural mortality or early safety at 30 days. The higher procedural complication was observed in 20-mm group due to significant differences in minor vascular and bleeding complications. Despite higher post-THV gradients and smaller indexed EOA in 20-mm group, no PPM was observed in 20-mm group. The mortality at 30 days and 1 year in 20-mm group was 4.8% and 16.7%, respectively. The patients who received very small THVs with 20-mm SP3 did not result in PPM and experienced favorable early safety and midterm outcome in our cohort.</p>","PeriodicalId":520798,"journal":{"name":"The International journal of angiology : official publication of the International College of Angiology, Inc","volume":" ","pages":"120-125"},"PeriodicalIF":0.9000,"publicationDate":"2021-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9272262/pdf/10-1055-s-0041-1732316.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of angiology : official publication of the International College of Angiology, Inc","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0041-1732316","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/6/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Transcatheter aortic valve replacement has been developed as an emerging technique to treat patients with aortic valve disease. However, safety and outcome data on extremely small transcatheter heart valves (THV) is limited. We aimed to assess hemodynamic profiles and clinical outcome of very small balloon expandable THVs with 20-mm Sapien 3 (SP3). We examined data for all patients who received third-generation SP3 THV at a single hospital. Complications and clinical outcomes were defined based on the VARC-2 criteria. Postoperative prosthesis-patient mismatch (PPM) was defined as indexed effective orifice area (EOA) < 0.85 cm 2 /m 2 . We compared clinical characteristics and outcome between patients with 20-mm ( n  = 21), 23-mm ( n  = 67), and 26- or 29-mm ( n  = 113) sized valves. The 20-mm group included significantly higher number of Asian and female populations with lower body surface area. The baseline CT annular area in the 20-mm group was 316.5 ± 24.9 mm 2 . There was no significant difference between groups in procedural mortality or early safety at 30 days. The higher procedural complication was observed in 20-mm group due to significant differences in minor vascular and bleeding complications. Despite higher post-THV gradients and smaller indexed EOA in 20-mm group, no PPM was observed in 20-mm group. The mortality at 30 days and 1 year in 20-mm group was 4.8% and 16.7%, respectively. The patients who received very small THVs with 20-mm SP3 did not result in PPM and experienced favorable early safety and midterm outcome in our cohort.

20毫米Sapien极小主动脉瓣置换术后假体与患者不匹配的发生率低
经导管主动脉瓣置换术是治疗主动脉瓣疾病的一种新兴技术。然而,极小经导管心脏瓣膜(THV)的安全性和结果数据有限。我们的目的是评估带有20毫米Sapien 3 (SP3)的极小球囊膨胀性thv的血流动力学特征和临床结果。我们检查了在一家医院接受第三代SP3 THV治疗的所有患者的数据。根据VARC-2标准确定并发症和临床结果。术后假体-患者失配(PPM)定义为指数有效孔面积(EOA) 2 / m2。我们比较了20毫米(n = 21)、23毫米(n = 67)、26毫米或29毫米(n = 113)瓣膜患者的临床特征和结果。在20毫米组中,具有下体表面积的亚洲和女性种群数量显著增加。20mm组CT基线环形面积为316.5±24.9 mm 2。在30天的手术死亡率和早期安全性方面,两组间无显著差异。20 mm组手术并发症较高,在小血管及出血并发症方面有显著差异。尽管20 mm组thv后梯度较高,指数EOA较小,但20 mm组未观察到PPM。20 mm组30天和1年死亡率分别为4.8%和16.7%。在我们的队列中,接受20毫米SP3的非常小的thv的患者没有导致PPM,并且具有良好的早期安全性和中期结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书