Profound hypercapnia but only moderate hypoxia found during underwater rugby play.

IF 0.7
Peter Lindholm, Henrik Lund, Lesley Blogg, Mikael Gennser
{"title":"Profound hypercapnia but only moderate hypoxia found during underwater rugby play.","authors":"Peter Lindholm,&nbsp;Henrik Lund,&nbsp;Lesley Blogg,&nbsp;Mikael Gennser","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Underwater rugby is a team sport where players try to score points with a negatively buoyant ball while submerged in a swimming pool. Reports of syncope incidents at the Swedish Championships led to us to investigate end-tidal oxygen and carbon dioxide levels during simulated match play.</p><p><strong>Methods: </strong>Eight male underwater rugby club players of varying experience participated. Repetitive measurements were made while players were defending during simulated match play. Each time a player surfaced they exhaled through a mouthpiece connected to a flow meter and a gas analyzer to measure tidal volume, PETO2 and PETCO2.</p><p><strong>Results: </strong>Measurements were made over 12 dives, with an average dive duration of 18.5 seconds. The mean maximal PETCO2 across the eight participants was 10.0 kPa (~75 mmHg) (range, 9.1-11.7 [~68-88]). The corresponding mean minimum PETO2 was 7.6 kPa (~57 mmHg) (6.3-10.4 [~47-78)). PETCO2 drifted upward, with the mean upward change from the first to last dive for each participant being +1.8 (~13.5 mmHg) (SD 1.74) kPa. A similar trend for PETO2 was not detected, with a mean change of -0.1 (~0.75 mmHg) (SD 3.79) kPa.</p><p><strong>Conclusion: </strong>Despite high PETCO2 values that were close to narcotic being recorded, these players seemed to regulate their urge to breathe based on hypoxia rather than hypercapnia.</p>","PeriodicalId":520823,"journal":{"name":"Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc","volume":" ","pages":"367-372"},"PeriodicalIF":0.7000,"publicationDate":"2022-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc","FirstCategoryId":"3","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Underwater rugby is a team sport where players try to score points with a negatively buoyant ball while submerged in a swimming pool. Reports of syncope incidents at the Swedish Championships led to us to investigate end-tidal oxygen and carbon dioxide levels during simulated match play.

Methods: Eight male underwater rugby club players of varying experience participated. Repetitive measurements were made while players were defending during simulated match play. Each time a player surfaced they exhaled through a mouthpiece connected to a flow meter and a gas analyzer to measure tidal volume, PETO2 and PETCO2.

Results: Measurements were made over 12 dives, with an average dive duration of 18.5 seconds. The mean maximal PETCO2 across the eight participants was 10.0 kPa (~75 mmHg) (range, 9.1-11.7 [~68-88]). The corresponding mean minimum PETO2 was 7.6 kPa (~57 mmHg) (6.3-10.4 [~47-78)). PETCO2 drifted upward, with the mean upward change from the first to last dive for each participant being +1.8 (~13.5 mmHg) (SD 1.74) kPa. A similar trend for PETO2 was not detected, with a mean change of -0.1 (~0.75 mmHg) (SD 3.79) kPa.

Conclusion: Despite high PETCO2 values that were close to narcotic being recorded, these players seemed to regulate their urge to breathe based on hypoxia rather than hypercapnia.

深度高碳酸血症,但只有适度缺氧发现在水下橄榄球比赛。
背景:水下橄榄球是一项团队运动,运动员在水下时用一个负浮力球得分。瑞典锦标赛晕厥事件的报道促使我们调查模拟比赛期间潮末氧气和二氧化碳水平。方法:对8名不同经验的男子水下橄榄球俱乐部运动员进行研究。在模拟比赛中,当球员防守时进行重复测量。每次球员浮出水面时,他们通过一个连接着流量计和气体分析仪的吹嘴呼气,以测量潮气量、petto2和PETCO2。结果:测量了12次潜水,平均潜水时间为18.5秒。8名参与者的平均最大PETCO2为10.0 kPa (~75 mmHg)(范围9.1-11.7[~68-88])。相应的平均最小PETO2为7.6 kPa (~57 mmHg)(6.3 ~ 10.4[~47 ~ 78))。PETCO2向上漂移,每个参与者从第一次到最后一次潜水的平均上升变化为+1.8 (~13.5 mmHg) (SD 1.74) kPa。PETO2没有类似的变化趋势,平均变化为-0.1 (~0.75 mmHg) (SD 3.79) kPa。结论:尽管记录的PETCO2值较高,接近麻醉,但这些球员似乎是基于缺氧而不是高碳酸盐岩来调节他们的呼吸冲动。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书