Michele Antonello, Andrea Xodo, Francesco Squizzato, Marco Zavatta, Carlo Maturi, Michele Piazza
{"title":"Preliminary experience with new generation balloon expandable stent-graft in the treatment of innominate artery obstructive disease.","authors":"Michele Antonello, Andrea Xodo, Francesco Squizzato, Marco Zavatta, Carlo Maturi, Michele Piazza","doi":"10.23736/S0021-9509.22.12158-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The aim of this study was to describe a single center preliminary experience with the use of a specific balloon expandable stent-graft for the treatment of innominate artery (IA) obstructive lesions.</p><p><strong>Methods: </strong>We report our experience with four male patients treated with Gore Viabahn balloon (Gore Medical, Flagstaff, AZ, USA) expandable stent-graft for different types of IA stenosis: three patients were symptomatic for vertebrobasilar insufficiency, while one patient was asymptomatic for cerebrovascular symptoms. The stent grafts were deployed using retrograde (N.=2) or antegrade approach (N.=2), aiming to cover the entire lesions length and to slightly protrude into the aortic arch. Post-dilatation was performed with a compliant balloon. One patient presented a tandem lesion (IA and right internal carotid artery) and after the stenting of the IA he was treated also with a carotid artery stenting during the same procedure.</p><p><strong>Results: </strong>Technical success was achieved in all patients. No perioperative or postoperative complications had been reported and the neurological disorders disappeared for the three symptomatic patients. After a mean clinical and radiological follow-up of 24±5 months, all the stents were patent and perfectly adapted to the vessels.</p><p><strong>Conclusions: </strong>This preliminary clinical experience shows that the use of the Gore Viabahn balloon (Gore Medical) expandable stent-graft seems safe and feasible for the treatment of the IA obstructive lesions, also in presence of irregular plaques and hostile anatomies for an endovascular treatment. Larger experiences and long-term data are mandatory.</p>","PeriodicalId":50245,"journal":{"name":"Journal of Cardiovascular Surgery","volume":" ","pages":"682-686"},"PeriodicalIF":1.4000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.23736/S0021-9509.22.12158-0","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/9/28 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The aim of this study was to describe a single center preliminary experience with the use of a specific balloon expandable stent-graft for the treatment of innominate artery (IA) obstructive lesions.
Methods: We report our experience with four male patients treated with Gore Viabahn balloon (Gore Medical, Flagstaff, AZ, USA) expandable stent-graft for different types of IA stenosis: three patients were symptomatic for vertebrobasilar insufficiency, while one patient was asymptomatic for cerebrovascular symptoms. The stent grafts were deployed using retrograde (N.=2) or antegrade approach (N.=2), aiming to cover the entire lesions length and to slightly protrude into the aortic arch. Post-dilatation was performed with a compliant balloon. One patient presented a tandem lesion (IA and right internal carotid artery) and after the stenting of the IA he was treated also with a carotid artery stenting during the same procedure.
Results: Technical success was achieved in all patients. No perioperative or postoperative complications had been reported and the neurological disorders disappeared for the three symptomatic patients. After a mean clinical and radiological follow-up of 24±5 months, all the stents were patent and perfectly adapted to the vessels.
Conclusions: This preliminary clinical experience shows that the use of the Gore Viabahn balloon (Gore Medical) expandable stent-graft seems safe and feasible for the treatment of the IA obstructive lesions, also in presence of irregular plaques and hostile anatomies for an endovascular treatment. Larger experiences and long-term data are mandatory.
期刊介绍:
The Journal of Cardiovascular Surgery publishes scientific papers on cardiac, thoracic and vascular surgery. Manuscripts may be submitted in the form of editorials, original articles, review articles, case reports, therapeutical notes, special articles and letters to the Editor.
Manuscripts are expected to comply with the instructions to authors which conform to the Uniform Requirements for Manuscripts Submitted to Biomedical Editors by the International Committee of Medical Journal Editors (www.icmje.org). Articles not conforming to international standards will not be considered for acceptance.