Evaluation of long-acting somatostatin analog injection devices by nurses: a quantitative study.

IF 1.3 Q4 ENGINEERING, BIOMEDICAL
Medical Devices-Evidence and Research Pub Date : 2012-01-01 Epub Date: 2012-12-14 DOI:10.2147/MDER.S37831
Daphne T Adelman, Andrea Burgess, Philippa R Davies
{"title":"Evaluation of long-acting somatostatin analog injection devices by nurses: a quantitative study.","authors":"Daphne T Adelman,&nbsp;Andrea Burgess,&nbsp;Philippa R Davies","doi":"10.2147/MDER.S37831","DOIUrl":null,"url":null,"abstract":"<p><p>The somatostatin analogs (SSAs) lanreotide Autogel/Depot and octreotide long-acting release are used to treat acromegaly and neuroendocrine tumors. The present study evaluated opinions on SSA injection devices, including a recently approved lanreotide new device (lanreotide-ND), among nurses in Europe and the USA. Nurses injecting SSAs for at least three patients per year (n = 77) were interviewed regarding SSA devices. Device attributes were rated via questionnaire; nurses were then timed administering test injections with lanreotide-ND and octreotide long-acting release. The most important delivery system attributes were easy/convenient preparation and injection (ranked in the top five by 70% of nurses), low clogging risk (58%), and high product efficacy (55%). Compared with the octreotide long-acting release device, lanreotide-ND scored higher on 15/16 attributes, had shorter mean preparation and administration time (329 versus 66 seconds, respectively; P ≤ 0.01) and a higher overall preference score (70 versus 114, respectively; P ≤ 0.01). The five most important lanreotide-ND attributes were: prefilled device, confidence a full dose was delivered, low clogging risk, easy/convenient preparation and injection, and fast administration. These device features could lead to improvements in clinical practice and benefit patients/caregivers who administer SSAs at home.</p>","PeriodicalId":47140,"journal":{"name":"Medical Devices-Evidence and Research","volume":" ","pages":"103-9"},"PeriodicalIF":1.3000,"publicationDate":"2012-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2147/MDER.S37831","citationCount":"30","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Devices-Evidence and Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/MDER.S37831","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2012/12/14 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 30

Abstract

The somatostatin analogs (SSAs) lanreotide Autogel/Depot and octreotide long-acting release are used to treat acromegaly and neuroendocrine tumors. The present study evaluated opinions on SSA injection devices, including a recently approved lanreotide new device (lanreotide-ND), among nurses in Europe and the USA. Nurses injecting SSAs for at least three patients per year (n = 77) were interviewed regarding SSA devices. Device attributes were rated via questionnaire; nurses were then timed administering test injections with lanreotide-ND and octreotide long-acting release. The most important delivery system attributes were easy/convenient preparation and injection (ranked in the top five by 70% of nurses), low clogging risk (58%), and high product efficacy (55%). Compared with the octreotide long-acting release device, lanreotide-ND scored higher on 15/16 attributes, had shorter mean preparation and administration time (329 versus 66 seconds, respectively; P ≤ 0.01) and a higher overall preference score (70 versus 114, respectively; P ≤ 0.01). The five most important lanreotide-ND attributes were: prefilled device, confidence a full dose was delivered, low clogging risk, easy/convenient preparation and injection, and fast administration. These device features could lead to improvements in clinical practice and benefit patients/caregivers who administer SSAs at home.

Abstract Image

Abstract Image

护士对长效生长抑素模拟物注射装置的评价:定量研究。
生长抑素类似物(SSAs) lanreotide autol /Depot和octreotide长效释放用于治疗肢端肥大症和神经内分泌肿瘤。本研究评估了欧洲和美国护士对SSA注射装置的意见,包括最近批准的lanreotide新装置(lanreotide- nd)。对每年至少为3例患者注射SSA的护士(n = 77)就SSA装置进行了访谈。通过问卷对器械属性进行评分;然后护士定时注射兰瑞肽- nd和奥曲肽长效释放剂。最重要的给药系统属性是易于/方便的制备和注射(70%的护士将其排在前五名)、低堵塞风险(58%)和高产品功效(55%)。与奥曲肽缓释剂相比,lanreotide-ND在15/16项指标上得分更高,平均制备时间和给药时间更短(分别为329秒和66秒);P≤0.01)和更高的总体偏好评分(分别为70比114;P≤0.01)。lanreotide-ND最重要的五个属性是:预填充装置、全剂量递送的信心、低堵塞风险、制备和注射容易/方便、给药快。这些设备的功能可以改善临床实践,并使在家使用SSAs的患者/护理人员受益。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Medical Devices-Evidence and Research
Medical Devices-Evidence and Research ENGINEERING, BIOMEDICAL-
CiteScore
2.80
自引率
0.00%
发文量
41
审稿时长
16 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信