{"title":"Development of a fast PCR protocol enabling rapid generation of AmpFℓSTR® Identifiler® profiles for genotyping of human DNA.","authors":"Amanda Foster,&nbsp;Nancy Laurin","doi":"10.1186/2041-2223-3-6","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Traditional PCR methods for forensic STR genotyping require approximately 2.5 to 4 hours to complete, contributing a significant portion of the time required to process forensic DNA samples. The purpose of this study was to develop and validate a fast PCR protocol that enabled amplification of the 16 loci targeted by the AmpFℓSTR® Identifiler® primer set, allowing decreased cycling times.</p><p><strong>Methods: </strong>Fast PCR conditions were achieved by substituting the traditional Taq polymerase for SpeedSTAR™ HS DNA polymerase which is designed for fast PCR, by upgrading to a thermal cycler with faster temperature ramping rates and by modifying cycling parameters (less time at each temperature) and adopting a two-step PCR approach.</p><p><strong>Results: </strong>The total time required for the optimized protocol is 26 min. A total of 147 forensically relevant DNA samples were amplified using the fast PCR protocol for Identifiler. Heterozygote peak height ratios were not affected by fast PCR conditions, and full profiles were generated for single-source DNA amounts between 0.125 ng and 2.0 ng. Individual loci in profiles produced with the fast PCR protocol exhibited average n-4 stutter percentages ranging from 2.5 ± 0.9% (THO1) to 9.9 ± 2.7% (D2S1338). No increase in non-adenylation or other amplification artefacts was observed. Minor contributor alleles in two-person DNA mixtures were reliably discerned. Low level cross-reactivity (monomorphic peaks) was observed with some domestic animal DNA.</p><p><strong>Conclusions: </strong>The fast PCR protocol presented offers a feasible alternative to current amplification methods and could aid in reducing the overall time in STR profile production or could be incorporated into a fast STR genotyping procedure for time-sensitive situations.</p>","PeriodicalId":89160,"journal":{"name":"Investigative genetics","volume":" ","pages":"6"},"PeriodicalIF":0.0000,"publicationDate":"2012-03-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1186/2041-2223-3-6","citationCount":"29","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Investigative genetics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/2041-2223-3-6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 29

Abstract

Background: Traditional PCR methods for forensic STR genotyping require approximately 2.5 to 4 hours to complete, contributing a significant portion of the time required to process forensic DNA samples. The purpose of this study was to develop and validate a fast PCR protocol that enabled amplification of the 16 loci targeted by the AmpFℓSTR® Identifiler® primer set, allowing decreased cycling times.

Methods: Fast PCR conditions were achieved by substituting the traditional Taq polymerase for SpeedSTAR™ HS DNA polymerase which is designed for fast PCR, by upgrading to a thermal cycler with faster temperature ramping rates and by modifying cycling parameters (less time at each temperature) and adopting a two-step PCR approach.

Results: The total time required for the optimized protocol is 26 min. A total of 147 forensically relevant DNA samples were amplified using the fast PCR protocol for Identifiler. Heterozygote peak height ratios were not affected by fast PCR conditions, and full profiles were generated for single-source DNA amounts between 0.125 ng and 2.0 ng. Individual loci in profiles produced with the fast PCR protocol exhibited average n-4 stutter percentages ranging from 2.5 ± 0.9% (THO1) to 9.9 ± 2.7% (D2S1338). No increase in non-adenylation or other amplification artefacts was observed. Minor contributor alleles in two-person DNA mixtures were reliably discerned. Low level cross-reactivity (monomorphic peaks) was observed with some domestic animal DNA.

Conclusions: The fast PCR protocol presented offers a feasible alternative to current amplification methods and could aid in reducing the overall time in STR profile production or could be incorporated into a fast STR genotyping procedure for time-sensitive situations.

Abstract Image

Abstract Image

Abstract Image

开发一种快速PCR协议,能够快速生成AmpF r STR®Identifiler®基因型,用于人类DNA的基因分型。
背景:法医STR基因分型的传统PCR方法需要大约2.5至4小时才能完成,这占了处理法医DNA样本所需时间的很大一部分。本研究的目的是开发并验证一种快速PCR方案,该方案能够扩增AmpF r STR®Identifiler®引物集靶向的16个位点,从而减少循环时间。方法:用传统的Taq聚合酶代替专为快速PCR设计的SpeedSTAR™HS DNA聚合酶,升级到温度上升速度更快的热循环器,修改循环参数(在每个温度下更短的时间),采用两步PCR方法,实现快速PCR条件。结果:优化方案所需总时间为26 min。使用Identifiler快速PCR方案扩增了147份法医相关DNA样本。杂合子峰高比不受快速PCR条件的影响,单源DNA含量在0.125 ng至2.0 ng之间时可以生成完整的谱。用快速PCR技术得到的基因图谱中,单个基因座的平均n-4口吃率从2.5±0.9% (THO1)到9.9±2.7% (D2S1338)不等。未观察到非腺苷化或其他扩增产物的增加。二人DNA混合物中的次要贡献等位基因被可靠地识别出来。与部分家畜DNA存在低水平的交叉反应性(单态峰)。结论:所提出的快速PCR方案为当前扩增方法提供了一种可行的替代方案,可以帮助减少STR谱制作的总时间,或者可以在时间敏感的情况下纳入快速STR基因分型程序。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书