{"title":"Assessment of intrastromal corneal ring segment position with anterior segment optical coherence tomography.","authors":"Ebru Gorgun, Raciha Beril Kucumen, Nursal Melda Yenerel, Ferda Ciftci","doi":"10.3928/15428877-20120301-01","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objective: </strong>To examine the exact position of implanted Keraring (Mediphacos, Belo Horizonte, Brazil) segments by high-resolution anterior segment optical coherence tomography (AS-OCT).</p><p><strong>Patients and methods: </strong>This study included 17 eyes of 13 patients with keratoconus who underwent uneventful intracorneal ring segment implantation with the aid of femtosecond laser. Eyes were evaluated by AS-OCT at the third postoperative month. Distance from the apex of the triangular cross-section of the ring segment to the anterior corneal surface and distances from two basal corners to the posterior corneal surface were measured.</p><p><strong>Results: </strong>Distance from apex to anterior corneal surface (263.1 ± 42.9 μm) was significantly smaller than target depth calculated intraoperatively (356.9 ± 35.7 μm, P < .001). Distance between outer basal corner and posterior corneal surface was significantly greater than distance between inner basal corner and posterior corneal surface.</p><p><strong>Conclusion: </strong>High-resolution AS-OCT is a rapid, convenient, and valuable technique in the follow-up of patients with implanted Keraring segments that may be helpful in predicting ring-related complications.</p>","PeriodicalId":54675,"journal":{"name":"Ophthalmic Surgery Lasers & Imaging","volume":" ","pages":"214-21"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3928/15428877-20120301-01","citationCount":"21","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmic Surgery Lasers & Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3928/15428877-20120301-01","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2012/3/8 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 21
Abstract
Background and objective: To examine the exact position of implanted Keraring (Mediphacos, Belo Horizonte, Brazil) segments by high-resolution anterior segment optical coherence tomography (AS-OCT).
Patients and methods: This study included 17 eyes of 13 patients with keratoconus who underwent uneventful intracorneal ring segment implantation with the aid of femtosecond laser. Eyes were evaluated by AS-OCT at the third postoperative month. Distance from the apex of the triangular cross-section of the ring segment to the anterior corneal surface and distances from two basal corners to the posterior corneal surface were measured.
Results: Distance from apex to anterior corneal surface (263.1 ± 42.9 μm) was significantly smaller than target depth calculated intraoperatively (356.9 ± 35.7 μm, P < .001). Distance between outer basal corner and posterior corneal surface was significantly greater than distance between inner basal corner and posterior corneal surface.
Conclusion: High-resolution AS-OCT is a rapid, convenient, and valuable technique in the follow-up of patients with implanted Keraring segments that may be helpful in predicting ring-related complications.
期刊介绍:
Ophthalmic Surgery, Lasers and Imaging, an official publication of ARVO/ISIE, provides clinically valuable, practical articles in the field of ophthalmology on a bimonthly basis. The Journal publishes original, peer-reviewed articles that delve into the entire spectrum of ophthalmic surgery and treatment, including experimental science, surgical techniques, and video surgical clips. Subscribers can also benefit from our featured On Line Advanced Release—read articles before they appear in the print issue!