Validation, repeatability and reproducibility of a noninvasive instrument for measuring thoracic and lumbar curvature of the spine in the sagittal plane.

Fabiana O Chaise, Cláudia T Candotti, Marcelo L Torre, Tássia S Furlanetto, Patricia P T Pelinson, Jefferson F Loss
{"title":"Validation, repeatability and reproducibility of a noninvasive instrument for measuring thoracic and lumbar curvature of the spine in the sagittal plane.","authors":"Fabiana O Chaise,&nbsp;Cláudia T Candotti,&nbsp;Marcelo L Torre,&nbsp;Tássia S Furlanetto,&nbsp;Patricia P T Pelinson,&nbsp;Jefferson F Loss","doi":"10.1590/s1413-35552011005000031","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The need for early identification of postural abnormalities without exposing patients to constant radiation has stimulated the development of instruments aiming to measure the spinal curvatures.</p><p><strong>Objective: </strong>To verify the validity, repeatability and reproducibility of angular measures of sagittal curvatures of the spine obtained using an adapted arcometer, by comparing them with Cobb angles of the respective curvatures obtained by using X-rays.</p><p><strong>Methods: </strong>52 participants were submitted to two procedures designed to evaluate the thoracic and lumbar curvatures: (1) X-ray examination from which the Cobb angles (CA) of both curvatures were obtained, and (2) measuring the angles with the arcometer (AA). Two evaluators collected the data using the arcometer, with the rods placed at T1, T12, L1 and L5 spinous processes levels in a way as to permit linear measurements which, with aid of trigonometry, supplied the AA.</p><p><strong>Results: </strong>There was a very strong and significant correlation between AA and CA (r=0.94; p<0.01), with no-significant difference (p=0.32), for the thoracic curvature. There was a strong and significant correlation for the lumbar curvature (r=0.71; p<0.01) between AA and CA, with no-significant difference (p=0.30). There is a very strong correlation between intra-evaluator and inter-evaluator AA.</p><p><strong>Conclusion: </strong>It was possible to quantify reliably the thoracic and lumbar curvatures with the arcometer and it can thus be considered valid and reliable and for use in evaluating spinal curvatures in the sagittal plane.</p>","PeriodicalId":520766,"journal":{"name":"Revista brasileira de fisioterapia (Sao Carlos (Sao Paulo, Brazil))","volume":" ","pages":"511-7"},"PeriodicalIF":0.0000,"publicationDate":"2011-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1590/s1413-35552011005000031","citationCount":"40","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista brasileira de fisioterapia (Sao Carlos (Sao Paulo, Brazil))","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1590/s1413-35552011005000031","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2011/11/3 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 40

Abstract

Background: The need for early identification of postural abnormalities without exposing patients to constant radiation has stimulated the development of instruments aiming to measure the spinal curvatures.

Objective: To verify the validity, repeatability and reproducibility of angular measures of sagittal curvatures of the spine obtained using an adapted arcometer, by comparing them with Cobb angles of the respective curvatures obtained by using X-rays.

Methods: 52 participants were submitted to two procedures designed to evaluate the thoracic and lumbar curvatures: (1) X-ray examination from which the Cobb angles (CA) of both curvatures were obtained, and (2) measuring the angles with the arcometer (AA). Two evaluators collected the data using the arcometer, with the rods placed at T1, T12, L1 and L5 spinous processes levels in a way as to permit linear measurements which, with aid of trigonometry, supplied the AA.

Results: There was a very strong and significant correlation between AA and CA (r=0.94; p<0.01), with no-significant difference (p=0.32), for the thoracic curvature. There was a strong and significant correlation for the lumbar curvature (r=0.71; p<0.01) between AA and CA, with no-significant difference (p=0.30). There is a very strong correlation between intra-evaluator and inter-evaluator AA.

Conclusion: It was possible to quantify reliably the thoracic and lumbar curvatures with the arcometer and it can thus be considered valid and reliable and for use in evaluating spinal curvatures in the sagittal plane.

在矢状面测量胸椎和腰椎曲度的无创仪器的验证、可重复性和再现性。
背景:需要在不让患者持续暴露于辐射的情况下早期识别姿势异常,这刺激了旨在测量脊柱曲率的仪器的发展。目的:通过与x射线测得的不同曲率的Cobb角进行比较,验证采用适应性关节计测量脊柱矢状面曲率角度的有效性、可重复性和再现性。方法:52名受试者接受两种评估胸腰椎曲度的程序:(1)x线检查,从中获得两个曲度的Cobb角(CA),(2)用arometer测量角度(AA)。两名评估人员使用arometer收集数据,将棒放置在T1, T12, L1和L5棘突水平,以便在三角函数的帮助下进行线性测量,从而提供AA。结果:AA与CA的相关性非常强且显著(r=0.94;结论:用椎弓形计可以可靠地量化胸椎和腰椎的曲率,因此可以认为它是有效和可靠的,可用于评估矢状面脊柱曲率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书