A feasibility pilot study of the effects of neurostimulation on swallowing function in Parkinson's Disease [version 2; peer review: 1 approved, 3 approved with reservations, 1 not approved].

Ayodele Sasegbon, Ulrike Hammerbeck, Emilia Michou, Ivy Cheng, Mengqing Zhang, Charlotte James, Shaheen Hamdy
{"title":"A feasibility pilot study of the effects of neurostimulation on swallowing function in Parkinson's Disease [version 2; peer review: 1 approved, 3 approved with reservations, 1 not approved].","authors":"Ayodele Sasegbon, Ulrike Hammerbeck, Emilia Michou, Ivy Cheng, Mengqing Zhang, Charlotte James, Shaheen Hamdy","doi":"10.12688/amrcopenres.13007.2","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Dysphagia often occurs during Parkinson's disease (PD) and can have severe consequences. Recently, neuromodulatory techniques have been used to treat neurogenic dysphagia. Here we aimed to compare the neurophysiological and swallowing effects of three different types of neurostimulation, 5 Hertz (Hz) repetitive transcranial magnetic stimulation (rTMS), 1 Hz rTMS and pharyngeal electrical stimulation (PES) in patients with PD.</p><p><strong>Method: </strong>12 PD patients with dysphagia were randomised to receive either 5 Hz rTMS, 1 Hz rTMS, or PES. In a cross-over design, patients were assigned to one intervention and received both real and sham stimulation. Patients received a baseline videofluoroscopic (VFS) assessment of their swallowing, enabling penetration aspiration scores (PAS) to be calculated for: thin fluids, paste, solids and cup drinking. Swallowing timing measurements were also performed on thin fluid swallows only. They then had baseline recordings of motor evoked potentials (MEPs) from both pharyngeal and (as a control) abductor pollicis brevis (APB) cortical areas using single-pulse TMS. Subsequently, the intervention was administered and post interventional TMS recordings were taken at 0 and 30 minutes followed by a repeat VFS within 60 minutes of intervention.</p><p><strong>Results: </strong>All interventions were well tolerated. Due to lower than expected recruitment, statistical analysis of the data was not undertaken. However, with respect to PAS swallowing timings and MEP amplitudes, there was small but visible difference in the outcomes between active and sham.</p><p><strong>Conclusion: </strong>PES, 5 Hz rTMS and 1 Hz rTMS are tolerable interventions in PD related dysphagia. Due to small patient numbers no definitive conclusions could be drawn from the data with respect to individual interventions improving swallowing function and comparative effectiveness between interventions. Larger future studies are needed to further explore the efficacy of these neuromodulatory treatments in Parkinson's Disease associated dysphagia.</p>","PeriodicalId":72183,"journal":{"name":"AMRC open research","volume":"3 ","pages":"19"},"PeriodicalIF":0.0000,"publicationDate":"2022-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7612876/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"AMRC open research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12688/amrcopenres.13007.2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Dysphagia often occurs during Parkinson's disease (PD) and can have severe consequences. Recently, neuromodulatory techniques have been used to treat neurogenic dysphagia. Here we aimed to compare the neurophysiological and swallowing effects of three different types of neurostimulation, 5 Hertz (Hz) repetitive transcranial magnetic stimulation (rTMS), 1 Hz rTMS and pharyngeal electrical stimulation (PES) in patients with PD.

Method: 12 PD patients with dysphagia were randomised to receive either 5 Hz rTMS, 1 Hz rTMS, or PES. In a cross-over design, patients were assigned to one intervention and received both real and sham stimulation. Patients received a baseline videofluoroscopic (VFS) assessment of their swallowing, enabling penetration aspiration scores (PAS) to be calculated for: thin fluids, paste, solids and cup drinking. Swallowing timing measurements were also performed on thin fluid swallows only. They then had baseline recordings of motor evoked potentials (MEPs) from both pharyngeal and (as a control) abductor pollicis brevis (APB) cortical areas using single-pulse TMS. Subsequently, the intervention was administered and post interventional TMS recordings were taken at 0 and 30 minutes followed by a repeat VFS within 60 minutes of intervention.

Results: All interventions were well tolerated. Due to lower than expected recruitment, statistical analysis of the data was not undertaken. However, with respect to PAS swallowing timings and MEP amplitudes, there was small but visible difference in the outcomes between active and sham.

Conclusion: PES, 5 Hz rTMS and 1 Hz rTMS are tolerable interventions in PD related dysphagia. Due to small patient numbers no definitive conclusions could be drawn from the data with respect to individual interventions improving swallowing function and comparative effectiveness between interventions. Larger future studies are needed to further explore the efficacy of these neuromodulatory treatments in Parkinson's Disease associated dysphagia.

Abstract Image

Abstract Image

Abstract Image

神经刺激对帕金森病患者吞咽功能影响的可行性试验研究[第 2 版;同行评审:1项通过,3项有保留意见通过,1项未通过]。
导言:吞咽困难经常发生在帕金森病(PD)期间,并可能造成严重后果。最近,神经调节技术被用于治疗神经源性吞咽困难。在此,我们旨在比较三种不同类型的神经刺激(5 赫兹重复经颅磁刺激(rTMS)、1 赫兹重复经颅磁刺激(rTMS)和咽部电刺激(PES))对帕金森病患者的神经生理学和吞咽效果:12名患有吞咽困难的帕金森病患者被随机分配接受5赫兹经颅磁刺激、1赫兹经颅磁刺激或咽部电刺激。在交叉设计中,患者被分配到一种干预措施中,同时接受真实刺激和假刺激。患者接受视频荧光屏(VFS)对其吞咽情况进行基线评估,从而计算出稀薄液体、糊状物、固体和杯饮的穿透吸入评分(PAS)。此外,还仅对稀薄液体的吞咽进行了吞咽计时测量。然后,使用单脉冲 TMS 对咽部和(作为对照的)外展肌(APB)皮层区域的运动诱发电位(MEPs)进行基线记录。随后进行干预,并在 0 分钟和 30 分钟时进行干预后 TMS 记录,然后在干预后 60 分钟内重复 VFS:所有干预的耐受性都很好。由于招募人数低于预期,因此未对数据进行统计分析。但是,在 PAS 吞咽时间和 MEP 振幅方面,积极干预和假干预的结果差异很小,但很明显:结论:PES、5赫兹经颅磁刺激和1赫兹经颅磁刺激对与帕金森病相关的吞咽困难是可以耐受的干预措施。由于患者人数较少,因此无法从数据中得出个别干预措施是否能改善吞咽功能以及干预措施之间的效果比较的明确结论。今后需要进行更大规模的研究,进一步探讨这些神经调节疗法对帕金森病相关吞咽困难的疗效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信