Allergic contact dermatitis due to a PVC table cover.

Occupational medicine (Oxford, England) Pub Date : 2010-12-01 Epub Date: 2010-09-15 DOI:10.1093/occmed/kqq137
J C Salles, F J Deschamps
{"title":"Allergic contact dermatitis due to a PVC table cover.","authors":"J C Salles,&nbsp;F J Deschamps","doi":"10.1093/occmed/kqq137","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Plastics are a common cause of occupational skin disorders such as irritant or allergic contact dermatitis (ACD).</p><p><strong>Case report: </strong>We report a case of occupational ACD due to a polyvinyl chloride (PVC) plastic table cover used as a mouse pad for which we performed patch tests and obtained positive patch tests for the PVC table cover. Composition testing revealed the presence of phthalates and phosphites, which may represent the specific allergens.</p><p><strong>Conclusions: </strong>Contact with some of the chemical components of the PVC table cover, together with a combination of sweating and friction, may have enhanced the allergenicity of these components. Workplace adjustment resulted in disappearance of the dermatitis.</p>","PeriodicalId":520727,"journal":{"name":"Occupational medicine (Oxford, England)","volume":" ","pages":"662-4"},"PeriodicalIF":0.0000,"publicationDate":"2010-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1093/occmed/kqq137","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Occupational medicine (Oxford, England)","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/occmed/kqq137","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2010/9/15 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

Background: Plastics are a common cause of occupational skin disorders such as irritant or allergic contact dermatitis (ACD).

Case report: We report a case of occupational ACD due to a polyvinyl chloride (PVC) plastic table cover used as a mouse pad for which we performed patch tests and obtained positive patch tests for the PVC table cover. Composition testing revealed the presence of phthalates and phosphites, which may represent the specific allergens.

Conclusions: Contact with some of the chemical components of the PVC table cover, together with a combination of sweating and friction, may have enhanced the allergenicity of these components. Workplace adjustment resulted in disappearance of the dermatitis.

聚氯乙烯桌罩引起的过敏性接触性皮炎。
背景:塑料是职业性皮肤疾病的常见原因,如刺激性或过敏性接触性皮炎(ACD)。病例报告:我们报告一例职业性ACD,原因是聚氯乙烯(PVC)塑料台套用作鼠标垫,我们对其进行了斑贴试验,并对PVC台套进行了阳性斑贴试验。成分测试显示存在邻苯二甲酸盐和亚磷酸盐,这可能代表特定的过敏原。结论:接触PVC台套的某些化学成分,再加上出汗和摩擦,可能会增强这些成分的致敏性。工作场所调整导致皮炎消失。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信