A multi-center retrospective comparative study of third generation Ceramic-on- Ceramic total hip arthroplasty in patients younger than 45 years with or without the sandwich liner: A ten-year minimum.

Bangjian He, Xigong Li, Rui Dong, Peijian Tong, Junying Sun
{"title":"A multi-center retrospective comparative study of third generation Ceramic-on- Ceramic total hip arthroplasty in patients younger than 45 years with or without the sandwich liner: A ten-year minimum.","authors":"Bangjian He,&nbsp;Xigong Li,&nbsp;Rui Dong,&nbsp;Peijian Tong,&nbsp;Junying Sun","doi":"10.1177/10225536221109960","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Ceramic-on-ceramic couplings are attractive alternative bearing surfaces that have been reported to eliminate or reduce problems related to polyethylene wear debris. However, the material in THA still remains one of the major concerns about the risk of fracture, due to its brittleness.</p><p><strong>Objective: </strong>The present study aims at reporting the fracture rate of a series of ceramic-on-ceramic THAs with use of the sandwich liner combined with a ceramic femoral head, and attempt to detect the relative risk factors, possible cause and assesse the medium-term clinical results.</p><p><strong>Methods: </strong>We retrospectively evaluated 282 patients (300 hips) with use of the sandwich liner ceramic-on-ceramic THA between 2001 and 2009 at three-centers. Patient assessment was based on demographic factors, including age, weight, gender and body-mass index. All patients were evaluated clinically and radio-graphically or computed tomography in consideration of dislocation, osteolysis, periprosthetic fracture, infection, loosening and implant fracture.</p><p><strong>Results: </strong>five ceramic sandwich liners fracture (1.7%) were observed at an average of 7.3 years follow-up. These factors were irrelevant to the ceramic liner fracture, including age (<i>p</i> = 0.205), weight (<i>p</i> = 0.241), gender (<i>p</i> = 0.553), body-mass index (<i>p</i> = 0.736), inclination (<i>p</i> = 0.727), and anteversion (<i>p</i> = 0.606). The overall survival was 91.4% at 12 years with revision as the endpoint. Other complications included dislocation in two, perprosthetic fracture in two and osteolysis in eight hips. No hip had aseptic loosening of the implants was seen.</p><p><strong>Conclusions: </strong>We found that the sandwich liner may be lead to a high rate of alumina fracture and osteolysis. We have discontinued the use of sandwich liner with THA since 2009.</p>","PeriodicalId":520682,"journal":{"name":"Journal of orthopaedic surgery (Hong Kong)","volume":" ","pages":"10225536221109960"},"PeriodicalIF":0.0000,"publicationDate":"2022-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of orthopaedic surgery (Hong Kong)","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/10225536221109960","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Background: Ceramic-on-ceramic couplings are attractive alternative bearing surfaces that have been reported to eliminate or reduce problems related to polyethylene wear debris. However, the material in THA still remains one of the major concerns about the risk of fracture, due to its brittleness.

Objective: The present study aims at reporting the fracture rate of a series of ceramic-on-ceramic THAs with use of the sandwich liner combined with a ceramic femoral head, and attempt to detect the relative risk factors, possible cause and assesse the medium-term clinical results.

Methods: We retrospectively evaluated 282 patients (300 hips) with use of the sandwich liner ceramic-on-ceramic THA between 2001 and 2009 at three-centers. Patient assessment was based on demographic factors, including age, weight, gender and body-mass index. All patients were evaluated clinically and radio-graphically or computed tomography in consideration of dislocation, osteolysis, periprosthetic fracture, infection, loosening and implant fracture.

Results: five ceramic sandwich liners fracture (1.7%) were observed at an average of 7.3 years follow-up. These factors were irrelevant to the ceramic liner fracture, including age (p = 0.205), weight (p = 0.241), gender (p = 0.553), body-mass index (p = 0.736), inclination (p = 0.727), and anteversion (p = 0.606). The overall survival was 91.4% at 12 years with revision as the endpoint. Other complications included dislocation in two, perprosthetic fracture in two and osteolysis in eight hips. No hip had aseptic loosening of the implants was seen.

Conclusions: We found that the sandwich liner may be lead to a high rate of alumina fracture and osteolysis. We have discontinued the use of sandwich liner with THA since 2009.

第三代陶瓷对陶瓷全髋关节置换术对45岁以下患者的多中心回顾性比较研究:至少10年。
背景:陶瓷对陶瓷联轴器是有吸引力的替代轴承表面,据报道,它可以消除或减少与聚乙烯磨损碎片相关的问题。然而,由于THA材料的脆性,它仍然是断裂风险的主要关注点之一。目的:本研究旨在报道陶瓷对陶瓷tha联合陶瓷股骨头夹心衬垫的骨折率,并试图发现相关危险因素、可能的原因和评估中期临床结果。方法:我们回顾性评估了282例(300髋)在2001年至2009年间在三中心使用夹层内衬陶瓷对陶瓷THA的患者。患者评估基于人口统计学因素,包括年龄、体重、性别和身体质量指数。考虑脱位、骨溶解、假体周围骨折、感染、松动和假体骨折,对所有患者进行临床、影像学或计算机断层检查。结果:平均随访7.3年,观察到5例陶瓷夹层骨折(1.7%)。年龄(p = 0.205)、体重(p = 0.241)、性别(p = 0.553)、体质指数(p = 0.736)、倾斜度(p = 0.727)和前倾(p = 0.606)与陶瓷衬垫骨折无关。以修订为终点,12年总生存率为91.4%。其他并发症包括2例脱位,2例假体骨折和8例髋关节骨溶解。未见髋关节无菌性假体松动。结论:我们发现夹层内衬可能导致高铝骨折和骨溶解率。自2009年起,我们已停止使用THA夹层衬垫。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信