{"title":"[Placement repeatability of individual oral stent used in radiotherapy of nasopharyngeal carcinoma].","authors":"Xiao-Qing Liu,&nbsp;Wei Luo,&nbsp;Shi-Rong Lin,&nbsp;Meng-Zhong Liu","doi":"10.5732/cjc.009.10010","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objective: </strong>Individual oral stent used in nasopharyngeal carcinoma (NPC) patients during radiotherapy can spare the oral mucosa and tongue. This study was to analyze the placement repeatability and feasibility of individual oral stent used in radiotherapy of NPC.</p><p><strong>Methods: </strong>Individual oral stents were made for 17 naive NPC patients, and three lead markers of 2.0 mm diameter were embedded in each oral stent. The patients wearing individual oral stent were immobilized by thermoplast mask and underwent CT scan. Before and every week during radiotherapy, orthogonal (antero-posterior and lateral) X-ray films were taken in conventional simulator, respectively. Displacements of leader markers in medio-lateral (M-L),antero-posterior (A-P) and cranio-caudal (C-C) directions were respectively calculated and compared on each patient's X-ray films. At the dose of 40 Gy, a repeated CT scan was done with the same thermoplast mask and positioning markers. The displacements of co-ordinating gravity center of three lead markers and three selected bony structures between two sets of CT images for each patient were calculated and compared by ANOVA.</p><p><strong>Results: </strong>A total of 240 X-ray films were taken. The displacements of lead markers were (0.69+/-0.54) mm in M-L direction, (0.49+/-0.62) mm in A-P direction, and (0.56+/-0.57) mm in C-C direction, and the overall vector displacement was (1.2+/-0.77) mm (range, 0-4.98 mm). In three-dimensional method, the displacements of co-ordinating gravity center of three lead markers were (0.75+/-0.68) mm in M-L direction, (1.25+/-1.12) mm in A-P direction, and (1.06+/-0.77) mm in C-C direction, and the overall vector displacement was (2.15+/-0.90) mm (range, 1-4.24 mm). The displacements between gravity center of three lead markers and three bony structures had no significant difference in M-L, A-P, and C-C directions (P>0.05). The overall vector displacements also had no significant difference (P=0.083).</p><p><strong>Conclusion: </strong>The placement repeatability of individual oral dental stent in the mouth is very good during radiotherapy of NPC, and dental stent has a fixed position relationship with bony structures.</p>","PeriodicalId":7559,"journal":{"name":"Ai zheng = Aizheng = Chinese journal of cancer","volume":"28 10","pages":"1103-7"},"PeriodicalIF":0.0000,"publicationDate":"2009-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ai zheng = Aizheng = Chinese journal of cancer","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5732/cjc.009.10010","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

Background and objective: Individual oral stent used in nasopharyngeal carcinoma (NPC) patients during radiotherapy can spare the oral mucosa and tongue. This study was to analyze the placement repeatability and feasibility of individual oral stent used in radiotherapy of NPC.

Methods: Individual oral stents were made for 17 naive NPC patients, and three lead markers of 2.0 mm diameter were embedded in each oral stent. The patients wearing individual oral stent were immobilized by thermoplast mask and underwent CT scan. Before and every week during radiotherapy, orthogonal (antero-posterior and lateral) X-ray films were taken in conventional simulator, respectively. Displacements of leader markers in medio-lateral (M-L),antero-posterior (A-P) and cranio-caudal (C-C) directions were respectively calculated and compared on each patient's X-ray films. At the dose of 40 Gy, a repeated CT scan was done with the same thermoplast mask and positioning markers. The displacements of co-ordinating gravity center of three lead markers and three selected bony structures between two sets of CT images for each patient were calculated and compared by ANOVA.

Results: A total of 240 X-ray films were taken. The displacements of lead markers were (0.69+/-0.54) mm in M-L direction, (0.49+/-0.62) mm in A-P direction, and (0.56+/-0.57) mm in C-C direction, and the overall vector displacement was (1.2+/-0.77) mm (range, 0-4.98 mm). In three-dimensional method, the displacements of co-ordinating gravity center of three lead markers were (0.75+/-0.68) mm in M-L direction, (1.25+/-1.12) mm in A-P direction, and (1.06+/-0.77) mm in C-C direction, and the overall vector displacement was (2.15+/-0.90) mm (range, 1-4.24 mm). The displacements between gravity center of three lead markers and three bony structures had no significant difference in M-L, A-P, and C-C directions (P>0.05). The overall vector displacements also had no significant difference (P=0.083).

Conclusion: The placement repeatability of individual oral dental stent in the mouth is very good during radiotherapy of NPC, and dental stent has a fixed position relationship with bony structures.

[鼻咽癌放疗中单个口腔支架置入的可重复性]。
背景与目的:鼻咽癌患者放疗期间使用单件口腔支架可保护口腔黏膜和舌部。本研究旨在分析单个口腔支架在鼻咽癌放疗中放置的可重复性和可行性。方法:对17例初诊鼻咽癌患者单独制作口腔支架,每个口腔支架内嵌3个直径2.0 mm的导联标记物。采用热塑性口罩固定患者,并行CT扫描。放疗前和放疗期间每周分别在常规模拟机上拍摄x线正后方和侧位片。在每位患者的x线片上分别计算并比较中外侧(M-L)、前后(A-P)和颅尾(C-C)方向的先导标记物的位移。在40 Gy的剂量下,使用相同的热塑性膜和定位标记物进行重复CT扫描。计算每例患者两组CT图像间3个导联标记物和3个选定骨结构的协调重心位移,并用方差分析进行比较。结果:共拍摄x线片240张。导联标记物在M-L方向的位移为(0.69+/-0.54)mm,在A-P方向的位移为(0.49+/-0.62)mm,在C-C方向的位移为(0.56+/-0.57)mm,总体矢量位移为(1.2+/-0.77)mm(范围0-4.98 mm)。三维方法中,3个导联标记物的协调重心位移在M-L方向为(0.75+/-0.68)mm,在A-P方向为(1.25+/-1.12)mm,在C-C方向为(1.06+/-0.77)mm,总体矢量位移为(2.15+/-0.90)mm(范围1 ~ 4.24 mm)。在M-L、A-P、C-C方向上,3种导联标记物重心与3种骨结构之间的位移差异无统计学意义(P>0.05)。总体矢量位移差异无统计学意义(P=0.083)。结论:鼻咽癌放疗时口腔内单个口腔支架放置重复性好,且支架与骨结构有固定的位置关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信